FC-FANWR-24R

Fan Unit
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Honeywell FC-FANWR-24R is the FC-FANWR-24R 24 VDC Fan Unit with Readback used for active cabinet cooling with monitored fan-speed readback in a documented Honeywell Safety Manager installation. Confirm the complete identity and installed system configuration before replacement.

Ask our team:

Get a quick price for: FC-FANWR-24R
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for FC-FANWR-24R

Technical specifications for FC-FANWR-24R

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    FC-FANWR-24R
  • Estimated shipping dimensions:
    39.1x14.1x6cm
  • Weight:
    1.44 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    Dual-fan cooling unit with readback
  • Supply:
    24 VDC
  • Fan count:
    2
  • Readback:
    Fan-speed status contact
  • Status indication:
    Green LED per fan above minimum speed
  • Execution:
    Conformally coated FC version
  • Current lifecycle reference:
    Honeywell System HINTS replacement assembly

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell FC-FANWR-24R is the FC-FANWR-24R 24 VDC Fan Unit with Readback used for active cabinet cooling with monitored fan-speed readback in a documented Honeywell Safety Manager installation.
  • Supply: 24 VDC
  • Fan count: 2
  • Readback: Fan-speed status contact
  • Status indication: Green LED per fan above minimum speed

The component remains matched to its installed host, interface hardware and engineering configuration. Commissioning restores that architecture and verifies the intended function under controlled conditions.

Important Notice: Confirm FC-FANWR-24R, its exact host, installed position, interfaces, configuration, diagnostics and controlled acceptance evidence before release.

Honeywell FC-FANWR-24R Manuals & Downloads

These documents are different: the first consolidates exact product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

FC-FANWR-24R 24 VDC Fan Unit with Readback
Honeywell FC-FANWR-24R is the FC-FANWR-24R 24 VDC Fan Unit with Readback used for active cabinet cooling with monitored fan-speed readback in a documented Honeywell Safety Manager installation.
Installed-system maintenance
Preserves the documented slot, termination, wiring and configuration during replacement.
Controlled commissioning
Restores power and signals in the approved sequence and reviews diagnostics.
Acceptance verification
Confirms the intended channel, network or safety function before release.
Read the applicable Honeywell installation instructions before work. Verify FC-FANWR-24R, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete FC-FANWR-24R identity on the hardware and maintenance record.
2
Place the affected process in the approved maintenance state.
3
Record the installed position, connectors, terminals, wiring and configuration before removal.
4
Isolate all documented power and field energy and apply ESD controls where required.
5
Inspect the replacement identity, revision, interfaces and mating hardware before installation.
6
Restore every conductor, cable, power path and configuration value to the approved record.
7
Review host, module, channel or network diagnostics after controlled energization.
8
Perform a controlled functional test before release.

Alternative Names

Alternative Names

FC-FANWR-24R

Technical notes

Technical notes

Install FC-FANWR-24R only in its documented Honeywell Safety Manager position. Preserve the exact interfaces, wiring and configuration, then verify diagnostics and active cabinet cooling with monitored fan-speed readback under controlled conditions.

FAQS

  • What does FC-FANWR-24R monitor while cooling the cabinet?
    It monitors fan speed and reports status through the readback circuit.
  • How many fans are built into FC-FANWR-24R?
    The unit contains two fans.
  • Which supply is required by FC-FANWR-24R?
    It uses 24 VDC.
  • How does FC-FANWR-24R show that an individual fan is above minimum speed?
    A green LED next to that fan illuminates.
  • When does the FC-FANWR-24R readback contact indicate both fans are healthy?
    The contact changes to the healthy state after both fans are above the monitored minimum speed.
  • What does the FC prefix identify on FC-FANWR-24R?
    It identifies the conformally coated execution.
  • Which details should be copied before replacing FC-FANWR-24R?
    Record connector polarity, airflow direction, mounting position, alarm logic and the existing readback state.
  • What acceptance test is appropriate for FC-FANWR-24R?
    Run both fans, confirm the two LEDs and readback contact, then verify cabinet airflow and alarm clearance.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat