Speak to a sourcing specialist
sales13@apterpower.com

FC-DCOM-232/485

RS232 and RS422/485 Communication Field Termination Assembly
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Honeywell FC-DCOM-232/485 provides the RS232 or RS422/485 field connection for compatible Safety Manager control processors.
  • Manufacturer part number
    FC-DCOM-232/485
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    11cm x 7cm x 6cm
  • Country of Origin
    USA
Get a quick price for FC-DCOM-232/485
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete FC-DCOM-232/485 reference, label photographs and required quantity. Check the FC label, connector arrangement, all three DIP settings, earth terminal and processor cable identities.

  • 1

    Confirm the offer

    Review the offered FC-DCOM-232/485 configuration, condition and included items. Confirm the FTA, earth terminal, internal processor cables, external serial cables and end-of-line terminators in the quotation.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date and delivery details for FC-DCOM-232/485 in the quotation.

  • Match the complete marking

    Match the complete Honeywell FC-DCOM-232/485 marking and the actual installed hardware configuration before approving the order. Check the FC label, connector arrangement, all three DIP settings, earth terminal and processor cable identities.

  • Check the offered item before ordering

    Request clear photographs of the offered FC-DCOM-232/485 and ask your maintenance team to compare its markings and interfaces with the installed equipment and applicable Honeywell instructions.

Technical specifications for FC-DCOM-232/485

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    FC-DCOM-232/485
  • Weight:
    0.14 kg
  • Tariff Code:
    8537101190
  • Processor supply:
    5 V DC +/-5%
  • Maximum current:
    500 mA
  • RS232 baudrate:
    0-250 kbaud
  • RS422/485 baudrate:
    0-2 Mbaud
  • RS232 topology:
    Point-to-point
  • RS422 topology:
    Point-to-point
  • RS485 full-duplex devices:
    32 maximum
  • RS485 half-duplex devices:
    16 maximum
  • Line conditioner:
    680 ohm pull-up and pull-down resistors
  • Rail provision:
    TS32 / TS35 x 7.5

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Honeywell FC-DCOM-232/485 sets the electrical boundary between processor communication cabling and the external serial network, with switch settings and termination matched to the chosen topology.
Processor connection: Communication and power through internal cables
Field selection: RS232 or RS422/485
Configuration focus: Master pin allocation, bias and end termination
The FTA is powered by the connected control processor or redundant processor pair and does not require a separate supply connection. Its cabinet-earth terminal connects internal cable shields and field-connector housings to the intended earth reference.

Two identical male nine-pin connectors serve RS422/485, while a female nine-pin connector serves RS232. Where only one RS485 connector is used, the other requires the specified end-of-line termination; connector gender and appearance do not replace the pin-allocation check.

Three DIP switches select master pin allocation and line conditioning. The required settings depend on the communication method; switch 3 must be ON for proper RS232 operation. The FTA is not suitable for the specified 1 or 2 Mbaud FSC-to-Safety-Manager SafeNet RS485 link.
Controller platform reference: Safety Manager communication FTA. Follow the applicable installation instructions and approved design.
System and supply context: Honeywell FC-DCOM-232/485 serves the Safety Manager communication FTA configuration. The examples below apply to the complete installed signal or control path.

Application scope: Select compatible companion hardware and retain the intended measurement or control function. Accessories are included only when itemized in the offered assembly.
Prepare Honeywell FC-DCOM-232/485 for its configured installation using these checks.
Serial topology record

Record processor cables, serial mode, duplex setting and all three DIP-switch positions. Identify whether the link is a supported Safety Manager relationship.

Processor and earth connection

Restore the processor-supplied internal connection and cabinet-earth terminal. Inspect connector housings and cable shields.

Pin allocation and termination

Compare Master-switch positions with straight-through or crossover cabling. Fit the required end-of-line termination at the unused network-end connector.

Bias and baudrate test

Apply the required line-conditioning settings and verify the rate, duplex and cable-length combination. For RS232, confirm switch 3 is ON.

Complete-link acceptance

Test normal data exchange, relevant communication-loss behavior and the configured processor arrangement. Remove temporary test connections before release.

Complete configuration retention

Retain the final FC-DCOM-232/485 identity, wiring and verified configuration with the machine maintenance record.

Alternative Names

Honeywell FC-DCOM-232/485

Technical notes

Power and earth: Use the processor-supplied connection and the specified cabinet-earth terminal. Do not introduce a separate field supply into the communication assembly.

Topology-dependent wiring: The Master switch changes the RS422/485 pin allocation. Check straight-through versus crossover cabling, both endpoint settings and the end-of-line terminator before judging the link.

Rate and cable limit: Cable length depends on both baudrate and duplex mode: at up to 100 kbaud, the limits are 10 m for RS232, 1.2 km for RS422/485 full duplex and 600 m for RS485 half duplex with the proper cable.

FAQ View All FAQ

  • Why does FC-DCOM-232/485 not need a separate supply pair?
    Its internal processor connection supplies power as well as communication. Retain the approved internal cables and cabinet earth instead of adding an independent supply.
  • Which switch is essential for RS232 operation on FC-DCOM-232/485?
    DIP switch 3 must be ON. Check the complete RS232 point-to-point setting and the correct female field connector before troubleshooting the external device.
  • What changes when the Master switch on FC-DCOM-232/485 is moved?
    It changes the RS422/485 connector pin allocation. Cable type and the setting at the opposite end must be considered together, especially when retaining one-to-one cables.
  • Why is a spare RS485 connector on FC-DCOM-232/485 not necessarily left open?
    The two connectors are identical, and when only one is used the other needs the prescribed end-of-line terminator. An unterminated network end can cause communication errors.
  • Can FC-DCOM-232/485 serve every 1 or 2 Mbaud SafeNet RS485 connection?
    No. It cannot be used for the specified FSC-to-Safety-Manager SafeNet link at those rates. Select the appropriate communication FTA for that system relationship.
  • How does half-duplex operation change the network limit for FC-DCOM-232/485?
    It has a different cable-length and device-count limit from full duplex. Review both the network topology and baudrate rather than retaining full-duplex assumptions.
  • Why should line conditioning on FC-DCOM-232/485 follow the actual topology?
    The bias resistors establish receiver behavior while transmitters are inactive. Incorrect settings can leave an unstable idle line or an unsuitable network load.
  • What does a successful local serial test fail to prove about FC-DCOM-232/485?
    It does not prove the full installed cable length, endpoint settings, termination or redundant-processor behavior. Validate the complete network under the intended operating configuration.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.