Match the complete marking
Match the complete Honeywell FC-DCOM-232/485 marking and the actual installed hardware configuration before approving the order. Check the FC label, connector arrangement, all three DIP settings, earth terminal and processor cable identities.
-
Check the offered item before ordering
Request clear photographs of the offered FC-DCOM-232/485 and ask your maintenance team to compare its markings and interfaces with the installed equipment and applicable Honeywell instructions.
Technical specifications for FC-DCOM-232/485
-
Manufacturer:Honeywell
-
Product Category:DCS Systems
-
Spare Part Number:FC-DCOM-232/485
-
Weight:0.14 kg
-
Tariff Code:8537101190
-
Processor supply:5 V DC +/-5%
-
Maximum current:500 mA
-
RS232 baudrate:0-250 kbaud
-
RS422/485 baudrate:0-2 Mbaud
-
RS232 topology:Point-to-point
-
RS422 topology:Point-to-point
-
RS485 full-duplex devices:32 maximum
-
RS485 half-duplex devices:16 maximum
-
Line conditioner:680 ohm pull-up and pull-down resistors
-
Rail provision:TS32 / TS35 x 7.5
Information
- Honeywell FC-DCOM-232/485 sets the electrical boundary between processor communication cabling and the external serial network, with switch settings and termination matched to the chosen topology.
Field selection: RS232 or RS422/485
Configuration focus: Master pin allocation, bias and end termination
Two identical male nine-pin connectors serve RS422/485, while a female nine-pin connector serves RS232. Where only one RS485 connector is used, the other requires the specified end-of-line termination; connector gender and appearance do not replace the pin-allocation check.
Three DIP switches select master pin allocation and line conditioning. The required settings depend on the communication method; switch 3 must be ON for proper RS232 operation. The FTA is not suitable for the specified 1 or 2 Mbaud FSC-to-Safety-Manager SafeNet RS485 link.
FC-DCOM-232/485 Original Technical Excerpt
Honeywell Safety Manager Hardware Reference, EP-SM.MAN.6284 Issue 2.1, DCOM-232/485 datasheet version 1.2. Selected original pages retain the applicable technical tables and interface context. PDF · 9 pages.FC-DCOM-232/485 Installation & Verification Guide
Apter Power field guide covering serial topology record, processor and earth connection, pin allocation and termination, validation and handover. PDF · 5 pages.
Application scope: Select compatible companion hardware and retain the intended measurement or control function. Accessories are included only when itemized in the offered assembly.
RS232 equipment connection
Provide a compatible point-to-point serial interface.RS422 point-to-point link
Match pin allocation and endpoint cable arrangement.RS485 multidrop communication
Apply the supported duplex, device-count and termination limits.Safety Manager serial integration
Use the FTA only in its supported controller and network relationships.
Record processor cables, serial mode, duplex setting and all three DIP-switch positions. Identify whether the link is a supported Safety Manager relationship.
Restore the processor-supplied internal connection and cabinet-earth terminal. Inspect connector housings and cable shields.
Compare Master-switch positions with straight-through or crossover cabling. Fit the required end-of-line termination at the unused network-end connector.
Apply the required line-conditioning settings and verify the rate, duplex and cable-length combination. For RS232, confirm switch 3 is ON.
Test normal data exchange, relevant communication-loss behavior and the configured processor arrangement. Remove temporary test connections before release.
Retain the final FC-DCOM-232/485 identity, wiring and verified configuration with the machine maintenance record.
Alternative Names
Technical notes
Power and earth: Use the processor-supplied connection and the specified cabinet-earth terminal. Do not introduce a separate field supply into the communication assembly.
Topology-dependent wiring: The Master switch changes the RS422/485 pin allocation. Check straight-through versus crossover cabling, both endpoint settings and the end-of-line terminator before judging the link.
Rate and cable limit: Cable length depends on both baudrate and duplex mode: at up to 100 kbaud, the limits are 10 m for RS232, 1.2 km for RS422/485 full duplex and 600 m for RS485 half duplex with the proper cable.
FAQ View All FAQ
-
Why does FC-DCOM-232/485 not need a separate supply pair?Its internal processor connection supplies power as well as communication. Retain the approved internal cables and cabinet earth instead of adding an independent supply.
-
Which switch is essential for RS232 operation on FC-DCOM-232/485?DIP switch 3 must be ON. Check the complete RS232 point-to-point setting and the correct female field connector before troubleshooting the external device.
-
What changes when the Master switch on FC-DCOM-232/485 is moved?It changes the RS422/485 connector pin allocation. Cable type and the setting at the opposite end must be considered together, especially when retaining one-to-one cables.
-
Why is a spare RS485 connector on FC-DCOM-232/485 not necessarily left open?The two connectors are identical, and when only one is used the other needs the prescribed end-of-line terminator. An unterminated network end can cause communication errors.
-
Can FC-DCOM-232/485 serve every 1 or 2 Mbaud SafeNet RS485 connection?No. It cannot be used for the specified FSC-to-Safety-Manager SafeNet link at those rates. Select the appropriate communication FTA for that system relationship.
-
How does half-duplex operation change the network limit for FC-DCOM-232/485?It has a different cable-length and device-count limit from full duplex. Review both the network topology and baudrate rather than retaining full-duplex assumptions.
-
Why should line conditioning on FC-DCOM-232/485 follow the actual topology?The bias resistors establish receiver behavior while transmitters are inactive. Incorrect settings can leave an unstable idle line or an unsuitable network load.
-
What does a successful local serial test fail to prove about FC-DCOM-232/485?It does not prove the full installed cable length, endpoint settings, termination or redundant-processor behavior. Validate the complete network under the intended operating configuration.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-