Product Describe:

Safety Control Switch Module
SIL 3 certified hardware
Provides 8 digital inputs
and 8 isolated relay outputs
Get a quick price for FC-SSWM01 51306930-176
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for FC-SSWM01 51306930-176

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    51306930-176
  • Estimated shipping dimensions:
    12x7x5cm
  • Weight:
    0.7 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Operating Range:
    12-24V DC
  • Response Time:
    Less than 10ms
  • Power Consumption:
    Less than 5W
  • Input Channels:
    8 Digital Inputs
  • Output Channels:
    8 Relay Outputs
  • Max Contact Rating:
    5 A @ 24 VDC
  • Operating Temperature:
    0°C to +60°C
  • Relative Humidity:
    5% to 95% (Non-condensing conditions)
  • Ingress Protection:
    IP20 inside the rack enclosure
  • Functional Safety Rating:
    Up to IEC 61508 SIL 3 Integrity Level compliant

Information

Overview Manuals Common Applications Product Precautions
The FC-SSWM01 is a specialized SC Switch Module for the Safety Manager system, facilitating critical manual actions including Program, Force, and Reset operations in industrial safety control environments. It features high-integrity digital input and relay output channels certified to SIL 3 safety standards.
    • Thermally stable design built to withstand harsh cabinet field conditions
    • Facilitates data routing between field safety instrumentation and central control architectures
    • Third-party TÜV audited to fulfill international process safety standards
The FC-SSWM01 utilizes the standard Honeywell Series C topology and mounts directly into a dedicated vertical backplane slot inside the safety control cabinet. The rear of the module features high-thickness gold-plated, oxidation-resistant edge connectors that perform high-frequency data polling with the main processor via a proprietary safety backbone bus. This underlying hardware connection uploads real-time field physical switch transitions to the central controller and maps them directly to the global variable table of the host control system, achieving tight synchronization between physical operations at the cabinet and remote monitoring software.

Within complex industrial electromagnetic environments, this hardware establishes a high-level dual optoelectronic and mechanical isolation barrier between external control loops and the internal logic core. This high-isolation architecture shields the system from high-voltage surges induced by the startup and shutdown of large field induction motors, high-frequency harmonics from variable frequency drives, or lightning strikes on control cables. Even under severe ground faults or high-voltage intrusion in the external loop, the internal isolation components protect the core computing backplane from physical damage, securing the underlying hardware integrity of the entire control system.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 Honeywell FC-SSWM01 SC Switch Module Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Oil and Gas Exploration
Installed in central safety cabinets on offshore drilling platforms and onshore gas production stations. Following an Emergency Shutdown triggered by abnormal wellhead pressure, operators use the physical reset switch on this module to clear latched states and re-initialize safety valves.

Petrochemical and Refining
Deployed within the Safety Instrumented Systems of catalytic cracking and hydroprocessing units. It allows instrument engineers to manually force or override specific field pressure sensor signals under live process conditions for online replacement or calibration of faulty instruments.

Fine Chemical and Pharmaceuticals
Applied in the automation control cabinets of highly exothermic reactors and highly toxic chemical dosing workshops. Between batch reaction intervals, switching the module's state via physical switches restricts or permits the downloading of process recipe configuration files.

Thermal and Nuclear Power Generation
Deployed inside Boiler Burner Management Systems and steam turbine overspeed protection loops. The module's isolated relay output channels feedback physical open/close states to the host rack, preventing loss of protection loop logic during widespread grid power fluctuations.

Semiconductor Wafer Cleanrooms
Deployed in the safety protection racks of Central Chemical Supply Systems within chip fabrication plants. It is utilized to temporarily and manually force the safety output states of specific chemical leakage sensors during pipeline maintenance.

Pulp and Paper Mills
Applied in the safety linkage control cabinets of high-pressure continuous digesters and black liquor recovery boilers, providing highly flexible relay closure channels under high-humidity environments to feedback the open/close positions of safety control valves.
 When maintaining the FC-SSWM01 module, physical insertion and removal must only be performed after completely isolating the cabinet power, as blind hot-swapping is strictly prohibited to prevent damage to the rear gold-plated edge connectors. Before executing a Force Override operation, a two-person verification of the field loops is required, a single person is strictly forbidden from blindly cutting off critical safety interlocks.

During routine operations, regularly inspect the panel LEDs to clear any channel open or short-circuit faults, and strictly control the internal cabinet humidity below ninety-five percent non-condensing. If the module triggers a solid red hardware fault light, repairing the internal isolation components on your own is strictly prohibited, and the entire module must be replaced with a genuine Honeywell part of the exact same model.

Alternative Names

FC SSWM01 FC-SSWMO1 FC-SSWM0I FC-SSWMOI

Technical notes

The FC-SSWM01 is a dedicated high-integrity functional control module for the Honeywell Safety Manager platform. Operating as a critical physical human-machine interface within the Safety Instrumented System architecture, this module handles specific manual safety overrides rather than continuous data streaming. It is purpose-built to manage three mission-critical dimensions: Program download licensing, field I/O manual force override, and post-incident safety loop reset, establishing a physical-level security barrier for high-risk industrial environments.

FAQ View All FAQ

  • What is the Honeywell FC-SSWM01 module?
    It is a specialized SC Switch Module within the Honeywell Safety Manager system, specifically designed to provide program control, manual force override, and system reset functions.
  • What is the core purpose of FC-SSWM01 in safety management systems?
    It provides a high-integrity physical interface for operators or engineers to execute system state changes or clear interlocks within high-risk loops, such as Emergency Shutdown (ESD) and Fire and Gas (F&G) systems.
  • How to properly install the FC-SSWM01 inside a control cabinet?
    With the cabinet power completely isolated, align the module vertically with the dedicated slot of the Safety Manager chassis, push firmly to ensure the rear gold fingers seat securely into the backplane receptacle, and tighten the physical retaining screws.
  • What types of direct industrial network communication does the FC-SSWM01 support?
    It does not operate directly as a communication card; instead, it routes data via the internal Safety Backbone to the main controller, which then handles upper-level networking such as Ethernet, Modbus, or OPC.
  • How to configure the FC-SSWM01 in automation engineering software?
    Within the Honeywell Safety Builder or Experion PKS engineering environment, add the FC-SSWM01 module under the I/O hardware tree, bind its part number 51306930-176 to the specific slot, and assign the corresponding digital channel variables.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.