Match the complete marking
Compare DS200SHVMG1AFE with the installed board and applicable GE documentation.
-
Check the offered item before ordering
Request photos of DS200SHVMG1AFE; compare board marking, plugs, jumpers and included items with the installed unit.
Technical specifications for DS200SHVMG1AFE
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:DS200SHVMG1AFE
-
Weight:0.34 kg
-
Tariff Code:8537101190
-
Board group:G1
-
Input shunt-signal span:-500 mV to +500 mV
-
Differential-frequency output span:0–500 kHz
-
Selectable CT attenuation:10:1
-
CT attenuation threshold:Insert above 144 mA secondary current
-
CT bypass threshold:Bypass at or below 144 mA
-
CT jumper bank:JP1–JP8; 8 positions
-
Voltage attenuation bank:JP9–JP17; 9 positions
-
Total hardware jumper positions:17
-
Low ac-voltage range:240–600 V ac
-
High ac-voltage range:601–1000 V ac
-
Measured voltage paths:3: ac line, motor armature and SCR bridge
-
Revision string:AFE
Information
- DS200SHVMG1AFE has a defined scr high voltage m-frame interface board role in the GE DC2000 M-frame drive-control system; selection depends on the complete board marking and installed execution.
CT boundary: Use 10:1 attenuation only when secondary current exceeds 144 mA.
Voltage boundary: JP9–JP17 distinguish 240–600 V ac from 601–1000 V ac.
Within the GE DC2000 M-frame drive-control system, evaluate this board together with its plugs, jumpers, connected power and feedback paths. Preserve the as-found interface map and revision evidence; a mechanically similar board is not automatically equivalent.
Commissioning should progress from identity and connection checks to controlled power-up, diagnostics and functional proof. Keep measured results, final status and open exceptions in the handover record.
-
GE DC2000 SHVM Original Instruction Excerpt
Original GE pages - PDF, 2 pages. M-frame current conversion, CT attenuation, voltage ranges and all 17 jumper positions. -
DS200SHVMG1AFE Installation & Commissioning Guide
Apter Power engineering guide - PDF, 5 pages. Replacement sequence, commissioning checks, diagnostics and acceptance evidence.
Compatibility boundary: Match the complete group, revision, connectors and configured signal path before replacement.
-
M-frame bridge interface
Interface the SCR bridge with DCFB or SDCI and PCCA paths. -
Current-transducer scaling
Set JP1–JP8 together for the installed ACCT secondary current. -
Voltage attenuation
Set JP9–JP17 for the documented ac line and dc bridge ranges. -
Controlled commissioning
Compare measured conversion and attenuation paths with the approved drive record.
Check every token in DS200SHVMG1AFE against the offered board and approved record.
Follow the site procedure for dc bus, field supply, control power, stored energy and electrostatic handling.
Photograph and label every connector, wire jumper and hardware jumper before removal.
Archive the applicable GE DC2000 M-frame drive-control system settings and drawings before replacement.
Check connectors, ribbon cables, terminal boards and cable condition before attributing a fault to the board.
Use an approved controlled test and retain measured values, diagnostics and acceptance evidence.
Alternative Names
Technical notes
Pre-purchase checks: Match the offered DS200SHVMG1AFE nameplate, board group, revision string, connector execution and jumper arrangement with the installed board and approved drawings.
Installed-system compatibility: Verify the exact GE DC2000 M-frame drive-control system position, mating boards, power or signal paths and configuration settings. A family reference or similar appearance does not establish interchangeability.
Quotation confirmation: Confirm available quantity, estimated dispatch date, lead-time starting event, included items and documents in writing.
FAQ View All FAQ
-
How should DS200SHVMG1AFE be identified before a replacement is approved?Use the complete DS200SHVMG1AFE marking, board group and revision string. Compare the installed position and documented scr high voltage m-frame interface board role before approval.
-
What evidence should be retained before removing DS200SHVMG1AFE?Photograph the complete marking, connector positions, jumper settings and status indications. Record the position in the GE DC2000 M-frame drive-control system.
-
How should the connectors for DS200SHVMG1AFE be checked during installation?Label each plug before removal, then restore every connection from the as-found record and the applicable GE manual. Never force a keyed connector.
-
What configuration boundary matters when commissioning DS200SHVMG1AFE?Use the exact board group, hardware execution and approved drive record. A similar board family or physical fit does not establish interchangeability.
-
How can a suspected DS200SHVMG1AFE fault be separated from wiring or carrier faults?Verify the documented supplies and reference signals first, inspect mating connectors and external wiring, then use a controlled substitution only after both signal paths are recorded.
-
What should be verified after fitting DS200SHVMG1AFE?Check normal host indications and the intended scr high voltage m-frame interface board function under an approved controlled test. Retain measured values and diagnostics with the handover record.
-
Can DS200SHVMG1AFE be replaced by a similar-looking assembly?No direct equivalence is established by appearance. Compare the complete code, group, revision, connector execution and installed configuration.
-
What handover record is appropriate after work on DS200SHVMG1AFE?Retain offered and removed markings, connection photographs, jumper or configuration evidence, measured checks, functional-test results and unresolved exceptions.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
DS200SHVMG1AFEProduct Details -
DS200TCEAG1BTFProduct Details -
DS200UPSAG1AGDProduct Details -
DS200KLDBG1ABCProduct Details -
DS200IMCPG1CGCProduct Details -
IS230TNTRH1CProduct Details -
DS215SDCCG1AProduct Details -
DS200SDCIG1ABAProduct Details -
DS200SDCIG2ABAProduct Details -
IS400AEBMH1AJDProduct Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.