IS200TRPGH2B

GAS TURBINE PRIMARY TRIP TERMINAL BOARD
In Stock

Product Describe:

GAS TURBINE 
PRIMARY TRIP 
TERMINAL BOARD
Mark Vle

Ask our team:

Get a quick price for: IS200TRPGH2B
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for IS200TRPGH2B

Technical specifications for IS200TRPGH2B

  • Manufacturer:
    General Electric
  • Product Category:
    Gas turbine control
  • Spare Part Number:
    IS200TRPGH2B
  • Estimated shipping dimensions:
    15.8x10x2.8cm
  • Weight:
    0.6 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Trip Solenoids:
    3
  • Solenoid Rate Voltage/Current:
    125 V dc
  • Flame Detectors:
    8
  • Number of output relay channels:
    12
  • Maximum Load Current:
    24 V dc
  • Temperature:
    -30 to 65C
  • Manual:
    GEH-6721G
  • Relays and Channels:
    Equipped with 3 main relays
  • Connection interface:
    includes 2 terminal blocks for wiring
  • Electrical parameters:
    Rated voltage is 24V DC or 125V DC

Information

Information

Overview Manuals Core functions and applications Maintenance and handling suggestions
The IS200TRPGH2B is a Gas Turbine Primary Trip Terminal Board manufactured and desiqned by General Electric as part of the Mark Vle Series used in GE Distributed turbine controI systems.
    • Mark VIe
    • Simplex, Redundant or TMR
    • TURBINE PRIMARY TRIP TERMINAL BOARD
The TRPG in the Mark Vle system is managed by the primary turbine protection controller (VTUR or PTUR) and includes nine magnetic relays organized into three voting circuits interfacing with three trip solenoids (ETDs).
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
GE Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Primary trip control: IS200TRPGH2B works in conjunction with TREG (emergency trip board), with TRPG providing negative DC power and TREG providing positive DC power to drive the trip solenoid. Flame detection interface: This board integrates 8 input interfaces for Geiger Mueller flame detectors, which is crucial for the safe operation of gas turbines. Simplex configuration: According to GE's naming convention, H2A and H2B versions are specifically designed for Simplex applications, with each trip solenoid equipped with a relay; In contrast, H1A/H1B is used for Triple Modular Redundancy (TMR) applications.
This board belongs to electrostatic sensitive devices (ESD Sensitive), and an anti-static wristband must be worn during operation to avoid direct contact with the conductive area of the circuit as much as possible.

FAQS

  • What is the function of the Gas Turbine Primary Trip Terminal Board (TRPG)?
    The TRPG is a critical component that manages the primary trip function by controlling relays connected to turbine protection solenoids, ensuring the safe operation of gas turbines.
  • How does the TRPG work in a TMR configuration?
    In TMR (Triple Modular Redundant) setups, the TRPG uses a two-out-of-three voting circuit to process inputs from three separate modules enhancing system reliability and fault tolerance.
  • What types of inputs does the TRPG handle?
    The TRPG processes inputs from eight Geiger-Mueller flame detectors and monitors relay control lines and contact statuses for diagnostic purposes.
  • What is the IS200TRPGH2B role of voltage pulses in the TRPG system?
    Voltage pulses generated by flame detectors are processed by the TRPG to measure flame intensity, with pulse rates analyzed to ensure proper turbine operation.
  • What does this IS200TRPGH2B Primary Trip Terminal Board PCB's conformal PCB coating entail?
    This IS200TRPGH2B Primary Trip Terminal Board PCB's conformal PCB coating is a thin layer of chemically-applied PCB coating made available to this IS200TRPGH2B Primary Trip Terminal Board device's entire base PCB.
  • Would this IS200TRPGH2B Primary Trip Terminal Board device be protected by any warranty upon my purchase here?
    Yes. This IS200TRPGH2B Primary Trip Terminal Board device would be protected by a guaranteed three-year PCB warranty upon any original purchase through AX.
Why Choose Apter Power?
1.Full one year warranty on all components
2.Professional after selling team
3.Same-day dispatch payment come
4.All units are fully tested well with certificate
5.Speak With an Expert Sales Representative
6.More than 20 years experience in automation
7.Stable employees more than 10+ years working experience
Common Applications
  • Electricity
  • Energy management
  • Petroleum
  • Natural gas
  • Chemical industry
  • Refinery
Delivery and payment
Delivery
Logistic partners UPS, FedEx and DHL
International delivery available
Same day dispatch from warehouse inventory
Warranty
All parts new original are covered by Apterpower 12 month warranty

Returns
No hassle returns policy

Dedicated customer support team

Payment options
We accept Bank transfers and the following methods of payment:
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.