Speak to a sourcing specialist
sales13@apterpower.com

KJ3221X1-BA1 12P2531X122 VE4003S2B2

DeltaV Series 2 HART analog output card
Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2 (1)
Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2 (2)
Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2 (3)
Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2 (1)
Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2 (2)
Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2 (3)
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2 is offered as a DeltaV Series 2 HART analog output card, based on the photographed KJ3221X1-BA1 / 12P2531X122 nameplate.
  • Manufacturer part number
    KJ3221X1-BA1 12P2531X122 VE4003S2B2
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    4.1cm × 12.5cm × 10.5cm
  • Country of Origin
    Malaysia
Get a quick price for KJ3221X1-BA1 12P2531X122 VE4003S2B2
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Confirm the complete reference

    We review the complete KJ3221X1-BA1 12P2531X122 VE4003S2B2 marking and its installed Emerson system configuration against the enquiry.

  • 1

    Check availability and scope

    We confirm the offered item, condition, any included accessories and an estimated dispatch date in the quotation.

  • 2

    Support the replacement review

    On request, we provide available label and connector photos so the maintenance team can compare the offered KJ3221X1-BA1 12P2531X122 VE4003S2B2 before ordering.

  • Match the complete marking

    Include KJ3221X1-BA1 12P2531X122 VE4003S2B2 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered KJ3221X1-BA1 12P2531X122 VE4003S2B2 with the installed equipment and applicable Emerson documentation.

Technical specifications for KJ3221X1-BA1 12P2531X122 VE4003S2B2

  • Manufacturer:
    Emerson
  • Product Category:
    DCS Systems
  • Spare Part Number:
    KJ3221X1-BA1 12P2531X122 VE4003S2B2
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Physical card identity:
    KJ3221X1-BA1
  • Card part number:
    12P2531X122
  • Nameplate function:
    AOUT HART SERIES-2
  • Analog signal family:
    4–20 mA output
  • Communication:
    HART
  • Identified revision:
    R on photographed unit
  • Nameplate manufacturer:
    Fisher-Rosemount Systems
  • Additional supplied reference:
    VE4003S2B2; requires order-code reconciliation

Information

Overview Downloads Applications / Compatibility Product Precautions
  • The photographed KJ3221X1-BA1 / 12P2531X122 is a DeltaV Series 2 HART analog output card; verify the additional VE4003S2B2 reference against the physical item.
Physical card: Series 2 HART analog output
Identity boundary: KJ3221X1-BA1 / 12P2531X122 label
Ordering check: Reconcile VE4003S2B2 before purchase
The photographed card is marked AOUT HART SERIES-2, identifying its physical I/O role as analog output with HART. In a configured DeltaV system, an analog output card sends commanded 4–20 mA signals to suitable field devices while HART communication supports device-level information on the loop.

The card label shows KJ3221X1-BA1, PN 12P2531X122 and revision R. The additional supplied string VE4003S2B2 is associated with an analog-input assembly in Emerson catalog material. It is retained as an ordering reference here but is not used to assign input-card electrical characteristics to the photographed output card.

For a replacement, compare the physical card, termination block, output-channel assignment, host release and configured HART devices. Confirm the role of VE4003S2B2 in the quotation before treating the combined string as one manufacturer-approved assembly.
Controller platform reference: Emerson DeltaV. Match the installed configuration and interfaces.
Technical downloads for Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2: a product technical reference and an installation verification guide.
These Apter Power documents consolidate the verified product facts and practical checks for the complete offered marking. Confirm the installed system configuration before service.
Application context: Configured DeltaV analog-output loops use the photographed KJ3221X1-BA1 / 12P2531X122 AOUT HART Series-2 card to command compatible field instruments and support HART communication where enabled.

Compatibility scope: Match the DeltaV host, termination assembly and channel configuration to the photographed card; reconcile the separate VE4003S2B2 reference before substitution.
Installation and commissioning checks for Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2.
Check the physical label

Match KJ3221X1-BA1 and 12P2531X122 on the offered output card.

Reconcile the extra code

Clarify VE4003S2B2 with the quotation because its catalog function differs from the photographed card.

Record channel use

Preserve the existing output-channel map and HART device identities.

Review termination

Compare the output termination block and cable connections before transfer.

Protect the process

Place controlled loops in their approved safe state before work.

Commission each loop

Verify output current and field response under the site procedure.

Alternative Names

Emerson KJ3221X1-BA1 12P2531X122 VE4003S2B2, KJ3221X1-BA1-12P2531X122-VE4003S2B2

Technical notes

Technical basis: Offered-item nameplate identifies KJ3221X1-BA1, 12P2531X122, AOUT HART SERIES-2 and Made in Malaysia. Emerson DeltaV M-series Traditional I/O data sheet assigns VE4003S2B2 to an analog-input assembly; that additional reference is not treated as an output-card specification.

Applicability: The output-card identity follows the offered-item nameplate. VE4003S2B2 remains an unreconciled additional reference and is not a source for output specifications.

Integration focus: Verify the configured analog-output loop response and HART communication with the installed field device after an approved replacement.

FAQ View All FAQ

  • Why does the physical label matter for KJ3221X1-BA1 12P2531X122 VE4003S2B2?
    The photographed KJ3221X1-BA1 card is marked AOUT HART SERIES-2. It identifies the actual card function more directly than the additional VE4003S2B2 sales reference.
  • Can VE4003S2B2 be used as the output-card rating for KJ3221X1-BA1 12P2531X122 VE4003S2B2?
    No. Emerson assigns VE4003S2B2 to an analog-input assembly. Confirm its relationship to the offered output card before assigning any assembly rating.
  • How should a HART valve positioner loop be checked after fitting KJ3221X1-BA1 12P2531X122 VE4003S2B2?
    Compare the commanded analog value, measured loop current, HART communication and device response with the approved loop test procedure.
  • What termination detail is needed before replacing KJ3221X1-BA1 12P2531X122 VE4003S2B2?
    Record the installed output termination-block marking and each channel connection. The card alone does not identify every field-wiring option.
  • How can an incorrect I/O function be avoided when ordering KJ3221X1-BA1 12P2531X122 VE4003S2B2?
    Request a clear front and side nameplate photo showing KJ3221X1-BA1, 12P2531X122 and AOUT HART SERIES-2; reconcile the separate VE reference in writing.
  • Can the photographed revision R of KJ3221X1-BA1 12P2531X122 VE4003S2B2 be replaced by another revision without review?
    Revision interchangeability has not been established from the label alone. Check the host release, termination and approved Emerson project records.
  • What should be recorded before removing KJ3221X1-BA1 12P2531X122 VE4003S2B2 from a running system?
    Save the channel map, loop safe-state plan, controller diagnostics, HART device identity and current termination configuration.
  • Why might a 4–20 mA loop fail even if KJ3221X1-BA1 12P2531X122 VE4003S2B2 is recognized by the host?
    The fault may lie in the termination, field supply, open circuit, polarity, output configuration or paired device. Diagnose the complete loop.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.