Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
Emerson IC695CPE330
Emerson IC695CPE330
Emerson IC695CPE330
Emerson IC695CPE330
Emerson IC695CPE330
Emerson IC695CPE330
Product image is representative; revision or series may vary. Contact us to request a specific version.

IC695CPE330

PACSystems RX3i CPE330 Controller
In Stock
Ships by Tuesday, October 6
Fast Shipping Available

Product Describe:

Emerson IC695CPE330 is a PACSystems RX3i backplane controller with 64 MB user memory and embedded Gigabit Ethernet/PROFINET connectivity. It supports a broad set of industrial Ethernet protocols for machine and process control.

Ask our team:

Get a quick price for: IC695CPE330
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for IC695CPE330

Technical specifications for IC695CPE330

  • Manufacturer:
    Emerson
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC695CPE330
  • Estimated shipping dimensions:
    16.5x16.5x10cm
  • Weight:
    1.25 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Form factor:
    Backplane
  • User memory:
    64 MB
  • Discrete I/O capacity:
    32K bits
  • Analog I/O capacity:
    32K words
  • Ethernet ports:
    3 Gigabit ports
  • Ethernet protocols:
    SRTP, Modbus TCP/IP, OPC UA, EGD, PROFINET, DNP3, IEC 61850 and IEC 104
  • USB interface:
    USB-A 2.0
  • Operating temperature:
    0 to 60 °C
  • Backplane power:
    24 VDC, 750 mA / 18 W
  • Reference Tables:
    32k bits

Information

Information

Overview Manuals Common Applications Product Precautions
IC695CPE330 provides high-performance controller execution and industrial Ethernet communications for a matched PACSystems RX3i installation.
  • Exact catalog identity IC695CPE330
  • PACSystems RX3i CPE330 Controller
  • Documented role: high-performance controller execution and industrial Ethernet communications
  • Controlled installation, diagnostics and functional verification

The component remains matched to the documented RX3i slot or carrier, terminal assembly, field power and engineering configuration. Commissioning preserves the installed architecture and verifies controlled response.

Important Notice: Confirm IC695CPE330, the complete RX3i host, hardware revision, slot, terminal block, field power, wiring, grounding, shielding, configuration, diagnostics and controlled acceptance evidence before release.

Emerson IC695CPE330 Manuals & Downloads

These documents are different: the first consolidates verified product and system data; the second provides installation checks, commissioning steps and acceptance records.

PACSystems RX3i planned maintenance
Restores high-performance controller execution and industrial Ethernet communications in the documented control architecture.
PACSystems RX3i CPE330 Controller replacement
Uses exact IC695CPE330 identity instead of an adjacent I/O or CPU execution.
Control-system refurbishment
Preserves the installed slot, terminal block, point map, power and engineering configuration.
Controlled recommissioning
Confirms diagnostics and the affected signal or control function before automatic operation.
Read the applicable Emerson installation instructions before work. Verify IC695CPE330, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete IC695CPE330 marking, module designation and documented RX3i installation position.
2
Place the controller, machine and connected process in the approved maintenance state.
3
Isolate controller and field power, prove the safe state and apply ESD controls before handling.
4
Record the slot, terminal block, every point assignment, common, shield and connected circuit before removal.
5
Verify the official electrical and configuration values documented for IC695CPE330; do not infer adjacent catalog executions.
6
Restore the approved backplane or carrier, terminal block, field power and engineering configuration.
7
Energize in the manufacturer sequence and review CPU, bus, module and channel diagnostics.
8
Complete a controlled signal, output or controller-response test before service release.

Alternative Names

Alternative Names

GE IC695CPE330 GE Fanuc IC695CPE330 1C695CPE330 IC695CPE33O

Technical notes

Technical notes

Install IC695CPE330 only in the documented PACSystems RX3i position. Preserve the as-found terminal, point and configuration records; then verify diagnostics and high-performance controller execution and industrial Ethernet communications under controlled conditions.

FAQS

  • How is IC695CPE330 distinguished from adjacent RX3i catalog numbers?
    Match the complete IC695CPE330 marking, the PACSystems RX3i CPE330 Controller designation and its recorded slot or carrier position.
  • What function is assigned to IC695CPE330 in the documented system?
    The module provides high-performance controller execution and industrial Ethernet communications in the matched PACSystems RX3i installation.
  • What is the official form factor for IC695CPE330?
    Emerson documents form factor as Backplane; verify that value against the installed execution before work.
  • Which user memory applies to IC695CPE330?
    The official value is 64 MB. Preserve the corresponding power, signal or controller configuration.
  • How should the documented discrete i/o capacity be checked on IC695CPE330?
    Confirm discrete i/o capacity is 32K bits and compare the as-found wiring or configuration with the approved record.
  • What evidence is needed for the analog i/o capacity of IC695CPE330?
    Record the installed condition and verify the official value 32K words during controlled commissioning.
  • What must be preserved before replacing IC695CPE330?
    Record the slot or carrier, terminal assembly, point assignments, wiring, commons, shields, firmware or configuration state and active diagnostics.
  • How is IC695CPE330 accepted after installation?
    Restore the documented hardware and point map, review module and controller diagnostics, and perform a controlled test of high-performance controller execution and industrial Ethernet communications.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.