PR6422-013-041 operates with PR6422-compatible signal converter, Fine-thread miniature bracket, Small conductive shaft or target, Open-end field termination.
Engineered applications include Small-shaft radial vibration, Tight-clearance position sensing, High-sensitivity eccentricity channels, Remote miniature probe installations.
Important Notice: Protect the fine M6 x 0.5 thread, confirm the ten-metre open-end wiring and PR6422 converter range, then set the narrow air gap with controlled mechanical clearance.
The first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.
Measures relative motion on small-diameter shafts.
Fits restricted probe mounting locations.
Provides high sensitivity for limited displacement spans.
Reaches distant cabinet terminals through its ten-metre lead.
Verify the complete PR6422-013-041 order code, M6 x 0.5 mounting interface and assigned PR6422 5 mm eddy-current system measuring point before work.
Place the monitored machine and its protection channel in the approved maintenance state before disturbing PR6422-013-041.
Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
Route the 10 m sensor lead without sharp bends, crushing, tensile load or contact with hot and moving surfaces.
Keep the LEMO or open-end connection clean, dry and fully identified before reconnecting the measurement loop.
Confirm the paired signal converter or monitor input, cable length and target material match the documented measuring chain.
Set the static gap within the documented linear region while preserving shaft and probe mechanical clearance.
Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.