PR6422-013-041

PR6422 5 mm miniature eddy-current displacement sensor
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

Emerson PR6422-013-041 is a PR6422 5 mm miniature eddy-current displacement sensor. It senses shaft-to-probe displacement for a matched Emerson signal converter and machinery-monitoring channel.

Ask our team:

Get a quick price for: PR6422-013-041
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for PR6422-013-041

Technical specifications for PR6422-013-041

  • Manufacturer:
    Emerson
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    PR6422-013-041
  • Estimated shipping dimensions:
    16x15x4cm
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Sensor family:
    PR6422
  • Sleeve thread:
    M6 x 0.5
  • Armor:
    Yes
  • Probe length Cx:
    50 mm
  • Overall sensor length C:
    55.3 mm
  • Adapter plug:
    Included
  • Total cable length:
    10 m
  • Cable end:
    Open ends
  • Static nominal range:
    +/-0.5 mm
  • Recommended dynamic range:
    25 to 250 um p-p
  • Sensitivity:
    16 V/mm
  • Nominal distance center:
    Approximately 0.8 mm
  • Basic air gap:
    0.15 to 0.35 mm
  • Operating temperature:
    -35 to +180 degC; +200 degC short term
  • Pressure at sensor head:
    10,000 hPa
  • Vibration endurance:
    5 g at 60 Hz

Information

Information

Overview Manuals Common Applications Product Precautions
Emerson PR6422-013-041 is pr6422 5 mm miniature eddy-current displacement sensor. It senses shaft-to-probe displacement for a matched Emerson signal converter and machinery-monitoring channel.
  • Uses a miniature M6 x 0.5 probe sleeve
  • Provides a ten-metre armored open-ended cable
  • Offers 16 V/mm nominal sensitivity
  • Supports narrow-clearance shaft measurements

PR6422-013-041 operates with PR6422-compatible signal converter, Fine-thread miniature bracket, Small conductive shaft or target, Open-end field termination.

Engineered applications include Small-shaft radial vibration, Tight-clearance position sensing, High-sensitivity eccentricity channels, Remote miniature probe installations.

Important Notice: Protect the fine M6 x 0.5 thread, confirm the ten-metre open-end wiring and PR6422 converter range, then set the narrow air gap with controlled mechanical clearance.

Apter Power PR6422-013-041 Manuals and Guides

Apter Power PR6422-013-041 Measurement-System Technical Reference PDFApter Power PR6422-013-041 Installation, Loop Check and Acceptance Workbook PDF

The first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.

Small-shaft radial vibration

Measures relative motion on small-diameter shafts.

Tight-clearance position sensing

Fits restricted probe mounting locations.

High-sensitivity eccentricity channels

Provides high sensitivity for limited displacement spans.

Remote miniature probe installations

Reaches distant cabinet terminals through its ten-metre lead.

Read the applicable Emerson machinery-monitoring instructions before work. Verify PR6422-013-041 and the installed Emerson PR6422 5 mm eddy-current measurement system configuration.
1

Verify the complete PR6422-013-041 order code, M6 x 0.5 mounting interface and assigned PR6422 5 mm eddy-current system measuring point before work.

2

Place the monitored machine and its protection channel in the approved maintenance state before disturbing PR6422-013-041.

3

Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.

4

Route the 10 m sensor lead without sharp bends, crushing, tensile load or contact with hot and moving surfaces.

5

Keep the LEMO or open-end connection clean, dry and fully identified before reconnecting the measurement loop.

6

Confirm the paired signal converter or monitor input, cable length and target material match the documented measuring chain.

7

Set the static gap within the documented linear region while preserving shaft and probe mechanical clearance.

8

Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.

Technical notes

Technical notes

Protect the fine M6 x 0.5 thread, confirm the ten-metre open-end wiring and PR6422 converter range, then set the narrow air gap with controlled mechanical clearance.

FAQS

  • What measurement or system function does PR6422-013-041 perform?
    PR6422-013-041 is a pr6422 5 mm miniature eddy-current displacement sensor. It senses shaft-to-probe displacement for a matched Emerson signal converter and machinery-monitoring channel.
  • Which installed hardware must be paired with PR6422-013-041?
    Use PR6422-013-041 with the documented Emerson PR6422 5 mm eddy-current measurement system components: PR6422-compatible signal converter, Fine-thread miniature bracket, Small conductive shaft or target.
  • How should the Sensor family value for PR6422-013-041 be verified?
    Confirm the complete nameplate and order code before work; the documented sensor family is PR6422.
  • What connection detail is critical when installing PR6422-013-041?
    Preserve every conductor, connector and shield identity, then follow the model-specific connection arrangement described in the controlling Emerson document.
  • How is PR6422-013-041 mechanically installed without changing measurement behavior?
    Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
  • What commissioning test should be completed for PR6422-013-041?
    Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.
  • What configuration record should be retained when replacing PR6422-013-041?
    Retain the as-found position, sleeve thread, cable or channel identity, gap or scaling value, diagnostics and final functional-test result.
  • Can PR6422-013-041 replace a similar Emerson model without engineering review?
    No direct substitution should be assumed; verify the full order code, measuring function, interface, cable or channel arrangement and the approved Emerson PR6422 5 mm eddy-current measurement system configuration.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.