Speak to a sourcing specialist
sales13@apterpower.com

9200-03-02-10-00

Seismoprobe Velocity Transducer
Ships by Friday, November 6
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 9200-03-02-10-00 is a two-wire moving-coil Seismoprobe velocity transducer with 90-degree mounting orientation and a side-mount connector.
  • Manufacturer part number
    9200-03-02-10-00
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    10cm x 4cm x 4cm
  • Country of Origin
    USA
Get a quick price for 9200-03-02-10-00
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 9200-03-02-10-00 marking and the installed 9200 Seismoprobe two-wire velocity measurement configuration with your enquiry.
  • 1

    Confirm the offer

    Check that the quotation identifies 9200-03-02-10-00 and specifies the supplied assembly, fittings and accessories.
  • 2

    Arrange dispatch

    Confirm the delivery details and receive a tracking reference when shipment is arranged.
  • Match the complete marking

    Include 9200-03-02-10-00 and the visible revision or assembly identity in your enquiry. Keep the full reference on the quotation.
  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 9200-03-02-10-00 with the installed equipment and applicable Bently Nevada documentation.

Technical specifications for 9200-03-02-10-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    9200-03-02-10-00
  • Weight:
    0.44 kg
  • Tariff Code:
    8537101190
  • Measurement:
    absolute casing or bearing-housing velocity
  • Sensing mechanism:
    two-wire moving coil
  • Mounting angle:
    90 degrees +/-2.5 degrees
  • Minimum operating frequency:
    4.5 Hz
  • Connector position:
    side mount, no cable
  • Mounting base:
    circular M10 x 1 stud
  • Approval selection:
    no approvals
  • External power:
    not required by moving-coil element

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Bently Nevada 9200-03-02-10-00. The 9200 Seismoprobe measures absolute vibration of a bearing housing, machine casing or structure by moving-coil action.
Operating temperature: -29 to +121 °C
Case material: Anodized A204 aluminum
Gasket material: Neoprene
M10 x 1 mounting torque: 5.6 N·m (50 in·lb)
The moving-coil element generates a voltage proportional to casing velocity without an excitation supply. At the manufacturer's reference condition of about 22 °C, 25 mm/s vibration at 100 Hz and a 10 kΩ load, sensitivity is 20 mV per mm/s (500 mV per in/s), ±5% when terminated and oriented at its calibration angle.

This 03 configuration has a 4.5 Hz minimum operating frequency. The typical response from that minimum to 1 kHz is +0/-3 dB; the published 1.25 kΩ ±5% coil resistance and 125 mH typical locked-coil inductance describe the two-wire element.

The 02 side connection has no integral cable, so the mating interconnect must be selected separately for the 10 circular M10 x 1 stud-base installation. Mount the sensitive axis in the required direction on a bearing housing or casing that actually transmits the vibration of interest.
Installed-system reference: 9200 Seismoprobe two-wire velocity measurement. Orient the sensing axis and select the separate side-connector cable.
Technical downloads for Bently Nevada 9200-03-02-10-00: selected original manufacturer pages and a model-specific Apter Power installation guide.
The technical reference preserves selected original manufacturer pages. The installation guide is prepared by Apter Power for this exact model; apply site procedures and the original equipment documentation during work.
Installation and commissioning checks for Bently Nevada 9200-03-02-10-00. Prepare a rigid measurement point, preserve the calibrated axis and verify the complete two-wire signal path.
Mounting face

Prepare a clean, flat and rigid bearing-housing or casing surface. A loose or flexible mount can distort amplitude and frequency response.

Calibrated orientation

Align the 90-degree calibrated axis with the required vibration direction. Record the orientation so future periodic measurements use the same axis.

Stud and seating

Use the circular M10 x 1 base and the specified mounting arrangement; the datasheet gives a 5.6 N·m mounting torque. Confirm full seating without substituting another thread.

Side-connector protection

Check clearance for the side connector and selected interconnect cable. Route the cable away from abrasion, tension and moving machine parts.

Signal termination

Use a suitable two-wire velocity input and the documented termination or input load when checking sensitivity. Avoid treating a changed load as a change in machine vibration.

Acceptance test

Check continuity and compare the output with a known operating condition or approved vibration test. Verify that the selected casing point gives a useful machine-condition signal.

Alternative Names

920003021000 Bently Nevada 9200-03-02-10-00

Technical notes

Signal principle: The two-wire moving-coil element produces a voltage proportional to vibration velocity.

Installation relationship: The selected 90-degree axis, side connector and M10 x 1 stud define the mechanical installation.

Technical reference: Bently Nevada 9200 and 74712 Seismoprobe Velocity Transducers, 141626 Rev. V.

FAQ View All FAQ

  • What does 9200-03-02-10-00 measure?
    It senses absolute vibration velocity of a bearing housing, casing or suitable structure.
  • What does option 03 specify on 9200-03-02-10-00?
    It selects nominal 90-degree mounting with a 4.5 Hz minimum operating frequency.
  • Where is the connector on 9200-03-02-10-00?
    Option 02 is a side-mount connector arrangement with no integral cable.
  • Which base does 9200-03-02-10-00 use?
    Option 10 selects a circular M10 x 1 stud base.
  • Does 9200-03-02-10-00 need an external power supply?
    The moving-coil two-wire sensing element generates its own velocity-proportional voltage.
  • What approval is selected on 9200-03-02-10-00?
    Option 00 selects no agency approval.
  • Can 9200-03-02-10-00 be mounted in any orientation without review?
    No. Its calibrated 90-degree orientation must match the measurement axis.
  • What determines the correct cable for 9200-03-02-10-00?
    The side connector and receiving instrument determine the separately selected interconnect cable.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.