The 330101-00-16-10-02-05 is a Bently Nevada 3300 XL 8 mm non-contacting eddy-current probe with a 3/8-24 UNF threaded case, no armor, 0.0 in unthreaded length, 1.6 in overall case length, 1.0 m (3.3 ft) standard cable, a miniature ClickLoc connector without a protector, and the CSA, ATEX, and IECEx approvals option.
- 3300 XL 8 mm unarmored proximity probe
- 3/8-24 UNF
- None
- 0.0 in
With a correctly matched 330130 extension cable and 3300 XL Proximitor Sensor, it converts probe-to-target distance into a proportional voltage for shaft vibration, shaft position, Keyphasor, and speed measurement on fluid-film-bearing machinery. For dependable measurement, follow official system-matching, target, mounting, wiring, environmental, and approval instructions.
Important Notice: The probe length plus extension-cable length must equal the selected Proximitor Sensor system length. Verify the nameplate and current approval documents before use.
Apter Power 330101-00-16-10-02-05 Product Manual
Important Notice: This Apter Power manual is prepared from the manufacturer source identified on the product page. Confirm the physical nameplate, current original-manufacturer documents, and applicable certification before installation or replacement.
Fluid-Film-Bearing MachineryProvides shaft vibration and position measurements at 3/8-24 UNF locations on rotating machinery.
Radial Shaft VibrationMeasures dynamic shaft motion relative to the probe mounting point.
Static Shaft PositionMeasures the static distance between the probe tip and a conductive shaft or target.
Axial or Thrust PositionSupports axial displacement measurement when the target and mounting geometry meet official requirements.
Keyphasor ReferenceSupports phase-reference measurement with the correct target geometry and monitoring input.
Speed MeasurementSupports rotational-speed measurement when the matched system and monitoring channel meet manufacturer requirements.
Read and follow Bently Nevada 3300 XL 8 mm Proximity Transducer System Datasheet 141194 Rev. AM and the applicable installation instructions before use. Verify the exact ordering code from the physical nameplate.
1Use a compatible 4.0 m extension cable for a 5.0 m system or 8.0 m extension cable for a 9.0 m system.
2Maintain the published 25.4 mm minimum cable bend radius and protect the unarmored lead.
3Verify case insertion depth, side-view clearance, target size, and shaft diameter before mounting.
4Set the final gap using the complete matched system and the actual target material.
5Confirm the 05 approval marking and applicable installation drawing before hazardous-area use.