The 330101-00-49-90-12-05 is a Bently Nevada 3300 XL 8 mm unarmored proximity probe with 3/8-24 UNF threads, 0.0 in unthreaded length, 4.9 in overall case, integral 9.0 m FluidLoc cable, ClickLoc connector without protector, and CSA, ATEX, and IECEx approvals option.
- 3300 XL 8 mm long-case FluidLoc probe
- 3/8-24 UNF
- None
- 0.0 in
The longer 4.9 in threaded case provides added mounting reach while the integral 9.0 m FluidLoc lead connects directly to a 9.0 m Proximitor Sensor for non-contacting shaft vibration, position, phase-reference, and speed measurements. For dependable measurement, follow the official system-matching, target, mounting, cabling, environmental, and approval instructions.
Important Notice: This 4.9 in case is fully threaded because the unthreaded option is 00. Confirm installed reach and internal clearance before use.
Apter Power 330101-00-49-90-12-05 Original Product Manual
Important Notice: This Apter Power original manual summarizes manufacturer-published technical data for the exact ordering code. Verify the physical nameplate and current manufacturer installation documents before use.
Fluid-Film-Bearing MachineryProvides non-contacting shaft vibration and position measurements on rotating machinery equipped with fluid-film bearings.
Radial Shaft VibrationMeasures dynamic shaft motion relative to the 4.9 in threaded probe case mounting location.
Static Shaft PositionMeasures the static gap between the probe tip and a conductive shaft or target through the complete transducer system output.
Deep Threaded MountingThe 4.9 in case provides more mounting reach than the 2.0 in configuration while retaining a fully threaded exterior.
Speed MeasurementSupports rotational-speed measurement when system length, target geometry, and monitoring-channel requirements are satisfied.
Machinery ProtectionSupplies a conditioned vibration or position signal to a compatible Bently Nevada monitoring system.
Read and follow Bently Nevada 3300 XL 8 mm Proximity Transducer System Datasheet 141194 Rev. AM and the applicable installation instructions before use. Verify the complete ordering code from the physical nameplate and match every component to the published system configuration.
1Confirm that the 4.9 in threaded case does not contact internal machine components and maintains required probe-tip clearances.
2Connect directly to the 9.0 m Proximitor Sensor without an extension cable.
3Protect the long unarmored FluidLoc lead and maintain the 25.4 mm bend radius.
4Gap the complete system with the intended target material and monitor the correct polarity and range.
5Verify the 05 approval markings and current installation requirements before hazardous-area use.