Match the complete marking
Match the complete 330103-00-05-05-01-CN marking, case geometry, cable length and connector arrangement to the installed measurement position.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 330103-00-05-05-01-CN with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 330103-00-05-05-01-CN
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330103-00-05-05-01-CN
-
Weight:0.05 kg
-
Tariff Code:8537101190
-
Measurement principle:Non-contact eddy current
-
Mounting thread:M10 x 1
-
Total probe length:0.5 m
-
Cable impedance:75 ohm triaxial
-
Cable insulation:FEP, standard cable
-
Probe tip material:PPS
-
Probe case material:AISI 303 or 304 stainless steel
-
Nominal probe DC resistance:7.45 ± 0.50 ohm, center to outer conductor
-
Standard probe temperature:-52°C to +177°C
-
Matched-system nominal scale factor:7.87 V/mm
-
Matched-system linear range:2 mm under specified calibration conditions
Information
- Bently Nevada 330103-00-05-05-01-CN places a short metric probe lead between the machine measurement point and the extension connection. Its supplied connector protector supports an insulated junction in the matched transducer chain.
Electrical length: 0.5 m total probe cable
Connection: ClickLoc connector with protector
The 0.5 m total probe length must be included in the complete electrical-length calculation. A compatible extension and Proximitor Sensor must form the selected 3300 XL 8 mm system; connector fit alone does not establish calibration.
The complete matched system provides a nominal 7.87 V/mm scale factor and a 2 mm linear measurement range. Radial-vibration setup uses approximately 1.27 mm gap, corresponding to -9 VDC under the specified AISI 4140 steel calibration conditions. Target material and geometry, component temperatures and the signal-conditioning configuration remain part of the measurement specification.
330103-00-05-05-01-CN Official Datasheet Excerpt
The original technical excerpt covers 3300 XL 8 mm probe construction, electrical behavior and system limits relevant to 330103-00-05-05-01-CN. PDF · 9 pages.330103-00-05-05-01-CN Installation & Verification Guide
Apter Power installation workflow for the 0.5 m probe, selected case interface, connector protection and commissioning checks. PDF · 5 pages.
Application scope: The applications below concern the complete calibrated measurement chain. Target material, physical clearance and monitor configuration determine suitability for each machine position.
Shaft vibration
Use the 0.5 m probe path to acquire non-contact shaft motion within the calibrated system range.Static shaft position
Condition the probe gap signal with the matched Proximitor Sensor for a monitor configured for position.Machine mounting
The 50 mm case and 0 mm unthreaded section define the available reach and support interface for this selection.Measurement-chain renewal
Use the 7.45 ± 0.50 ohm probe resistance as one isolated continuity check before a full gap-response verification.
Limit M10 x 1 thread engagement to 15 mm. Case length does not increase this limit.
The 0.5 m total probe length must be included in the complete electrical-length calculation. A compatible extension and Proximitor Sensor must form the selected 3300 XL 8 mm system; connector fit alone does not establish calibration.
The ClickLoc connector is supplied with a connector protector. Prevent contact with surrounding conductive surfaces.
Apply the probe temperature limit separately from the lower Proximitor operating-temperature limit.
Verify target material and geometry. AISI 4140 steel is the reference calibration target.
Check actual DC gap and response to controlled displacement before restoring protection.
Alternative Names
Technical notes
System relationship: The 0.5 m total probe length must be included in the complete electrical-length calculation. A compatible extension and Proximitor Sensor must form the selected 3300 XL 8 mm system; connector fit alone does not establish calibration.
Connection protection: The standard ClickLoc connection is supplied with a connector protector. Keep connector insulation, mechanical support and pressure containment separate.
Calibration boundary: The complete matched system provides a nominal 7.87 V/mm scale factor and a 2 mm linear measurement range. Radial-vibration setup uses approximately 1.27 mm gap, corresponding to -9 VDC under the specified AISI 4140 steel calibration conditions.
FAQ View All FAQ
-
Which cable section completes a 5 m chain using 330103-00-05-05-01-CN?A 0.5 m probe requires a matching 4.5 m extension to form a 5 m electrical chain. Use the corresponding 3300 XL 8 mm Proximitor calibration and compatible components.
-
What is supplied around the cable connector of 330103-00-05-05-01-CN?Connector option 01 supplies the miniature coaxial ClickLoc connector with a connector protector and standard cable. The protector insulates the junction; it does not turn the cable into an armored or FluidLoc version.
-
How is the metric mounting arrangement of 330103-00-05-05-01-CN defined?The selected case has an M10 x 1 thread, 50 mm overall case length and no unthreaded section. Thread engagement is limited separately to 15 mm.
-
Can the lead on 330103-00-05-05-01-CN be shortened to move its junction?Do not shorten or splice the calibrated probe cable. Changing the cable changes the electrical measurement chain; select a correctly matched probe and extension arrangement instead.
-
What continuity value applies to the 0.5 m 330103-00-05-05-01-CN lead?Measure center-to-outer conductor resistance with the probe disconnected. The nominal value is 7.45 ± 0.50 ohm; an open or short needs resolution before system response testing.
-
Does the connector protector on 330103-00-05-05-01-CN provide a pressure seal?No. Connector insulation is separate from probe pressure sealing. Do not use a connector protector as a fluid-containment component.
-
How should 330103-00-05-05-01-CN be set up for radial-vibration measurement?With the complete matched chain energized as specified, establish approximately -9 VDC gap voltage, corresponding to about 1.27 mm under the AISI 4140 steel calibration conditions. Verify the actual response after adjustment.
-
Must the Proximitor Sensor paired with 330103-00-05-05-01-CN tolerate the probe temperature?No. The standard probe operating range is -52°C to +177°C, while the Proximitor operating limit is -52°C to +100°C. Locate each component within its own operating envelope.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313