Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 146054-011-20-02-05
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 146054-011-20-02-05

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    146054-011-20-02-05
  • Estimated shipping dimensions:
    22x18x1.8cm
  • Weight:
    0.1 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Probe construction:
    Ceramic-capped sensing tip
  • Mounting thread:
    3/8-24 UNF
  • Case length:
    1.1 in
  • Lead length:
    2 m
  • Connector:
    Standard ClickLoc
  • Approval option:
    Multiple approvals

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 146054-011-20-02-05 is a ceramic-capped 3300 proximity probe with a 3/8-24 UNF threaded case, 1.1 in case length, 2 m lead, standard ClickLoc connector and multiple approvals.
  • Probe construction: Ceramic-capped sensing tip
  • Mounting thread: 3/8-24 UNF
  • Case length: 1.1 in
  • Lead length: 2 m

Use 146054-011-20-02-05 only with the documented Bently Nevada host, interface, mounting and cable arrangement. Verify identity, configuration and measured response before returning the monitored machine to service.

Important Notice: Protect the ceramic sensing tip. Verify thread engagement, 1.1 in case length, 2 m lead, ClickLoc connection, matched system length and approvals before commissioning.

Apter Power 146054-011-20-02-05 Manuals and Guides

The first document presents model-specific technical identity and engineering data. The second is a separate installation, connection, commissioning and acceptance workbook.

Harsh-environment proximity sensing
Uses the documented ceramic-capped probe construction.
Radial vibration measurement
Monitors non-contacting shaft vibration.
Axial position measurement
Supports verified position-measurement geometry.
Matched-system replacement
Preserves the approved cable and sensor combination.
Before isolation, installation, wiring or controlled start-up, confirm the complete 146054-011-20-02-05 identity and the installed Bently Nevada system arrangement.
1
Confirm the complete 146054-011-20-02-05 marking.
2
Verify the 3/8-24 UNF thread and 1.1 in case length.
3
Place the machine and monitoring channel in the approved maintenance state.
4
Protect the ceramic tip and 2 m lead from impact and bending.
5
Confirm the standard ClickLoc connector is clean and fully seated.
6
Match the probe to the documented extension cable and Proximitor Sensor.
7
Run gap, polarity, linear-response and alarm tests.
8
Retain the probe identity and final acceptance record.

Technical notes

Protect the ceramic sensing tip. Verify thread engagement, 1.1 in case length, 2 m lead, ClickLoc connection, matched system length and approvals before commissioning.

FAQ View All FAQ

  • What is Bently Nevada 146054-011-20-02-05?
    Bently Nevada 146054-011-20-02-05 is a ceramic-capped 3300 proximity probe with a 3/8-24 UNF threaded case, 1.1 in case length, 2 m lead, standard ClickLoc connector and multiple approvals.
  • Which documented attributes identify 146054-011-20-02-05?
    Probe construction: Ceramic-capped sensing tip; Mounting thread: 3/8-24 UNF; Case length: 1.1 in; Lead length: 2 m; Connector: Standard ClickLoc; Approval option: Multiple approvals.
  • Where is 146054-011-20-02-05 commonly applied?
    Harsh-environment proximity sensing, Radial vibration measurement, Axial position measurement, Matched-system replacement.
  • What should be checked before installing 146054-011-20-02-05?
    Confirm the complete 146054-011-20-02-05 marking. Verify the 3/8-24 UNF thread and 1.1 in case length. Place the machine and monitoring channel in the approved maintenance state.
  • What connection or cable checks apply to 146054-011-20-02-05?
    Protect the ceramic tip and 2 m lead from impact and bending. Confirm the standard ClickLoc connector is clean and fully seated. Match the probe to the documented extension cable and Proximitor Sensor.
  • How should 146054-011-20-02-05 be commissioned?
    Run gap, polarity, linear-response and alarm tests.
  • What is important when replacing 146054-011-20-02-05?
    Protect the ceramic sensing tip. Verify thread engagement, 1.1 in case length, 2 m lead, ClickLoc connection, matched system length and approvals before commissioning.
  • What record should be retained for 146054-011-20-02-05?
    Retain the probe identity and final acceptance record.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.