Speak to a sourcing specialist
sales13@apterpower.com

II5910

Inductive Proximity Sensor
IFM Electronic II5910
IFM Electronic II5910
IFM Electronic II5910
IFM Electronic II5910
IFM Electronic II5910
IFM Electronic II5910
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

ifm II5910 is an inductive proximity sensor with a normally open PNP output. Its flush-mountable construction detects metal targets without mechanical contact in factory-automation equipment.
  • Manufacturer part number
    II5910
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    7.5cm x 3.0cm x 3.0cm
  • Country of Origin
    Germany
Get a quick price for II5910
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete II5910 reference, label photographs and required quantity. Include the installed interface and hardware revision.

  • 1

    Confirm the offer

    Review the offered II5910 execution, New, original product condition and itemized accessories against the retained application.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.

  • Match the complete marking

    Compare the full ifm II5910 marking, hardware execution and mating interfaces with the installed position before approving a replacement.

  • Check the offered item before ordering

    Request clear photographs of the offered II5910 marking and connections. Ask the maintenance team to compare them with the applicable ifm instructions and the installed circuit or system design.

Technical specifications for II5910

  • Manufacturer:
    IFM Electronic
  • Product Category:
    General Automation
  • Spare Part Number:
    II5910
  • Weight:
    0.13 kg
  • Tariff Code:
    8537101190
  • Output:
    PNP, normally open
  • Supply voltage:
    10–32 V DC
  • Sensing range:
    15 mm nominal
  • Assured operating distance:
    0–12.15 mm
  • Switching frequency:
    100 Hz
  • Output current:
    200 mA continuous maximum
  • Output voltage drop:
    2.5 V maximum
  • Operating temperature:
    −40 to +70 °C
  • Protection:
    IP67
  • Connection:
    M12 A-coded, 3 contacts

Information

Overview Downloads Applications / Compatibility Product Precautions
  • II5910 converts the arrival of a metal target into a discrete switching signal. Reliable position detection depends on the target material, approach path and receiving input, rather than nominal sensing distance alone.
Detection task: contactless presence and position feedback for moving metal parts
Installation approach: flush mounting within a verified target clearance
Integration boundary: a discrete PNP switching signal, not an analogue distance measurement
The yellow switching indication is visible through four LED windows. It provides a local indication of the sensor output state, while the controller input must be checked separately to confirm that the signal reaches the application. The housing uses white-bronze-coated brass and a PBT sensing face.

Sensing performance depends on the target metal. The correction factors are 1 for steel, 0.7 for stainless steel, 0.5 for brass, 0.4 for aluminium and 0.3 for copper. These relative factors describe material influence; they do not remove the need to check target geometry and working clearance in the machine.

The A-coded connector has three gold-plated contacts. Reverse-polarity, overload and pulsed short-circuit protection are provided. Mounting and electrical acceptance remain separate checks: secure the flush-mounted sensor, then prove both target-present and target-absent states through the connected input and control logic.
Controller platform reference: ifm inductive position detection. Check the target and PNP input circuit.
Original ifm technical pages applicable to II5910 and its stated system context. Installation topics include: evaluate the actual metal target; prepare flush mounting; verify pnp wiring.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
Prepare ifm II5910 for its configured installation using these checks.
Evaluate the actual metal target

Record its material, size and motion. Establish a working position with adequate margin below the applicable sensing limit rather than using a steel reference blindly.

Prepare flush mounting

Check the threaded attachment and surrounding metal arrangement. Secure the sensor without damaging the sensing face or exceeding the specified mechanical constraints.

Verify PNP wiring

Identify supply, common and switching connection using the actual connector diagram. Confirm the receiving input provides the correct PNP-compatible circuit.

Test motion and load

Exercise the real approach and withdrawal path and measure switching behavior. Check the output under its intended load and investigate any protection cycling.

Confirm sealing and repeatability

Inspect the completed connector seal and cable support. Repeat the target test over the required travel and retain the accepted switching positions.

Control the return to service

Keep the affected process in its approved maintenance state until field indications and the intended control or monitoring response have both been checked.

Alternative Names

ifm II5910

Technical notes

Electrical observation: Measure supply and switched output against the intended common with the actual input connected. An unloaded output measurement cannot establish the receiving input margin.

Mechanical acceptance: Check the target-absent state with surrounding metal in place, then test the complete travel. Retain separate approach and withdrawal positions after final mounting.

FAQ View All FAQ

  • How can a yellow II5910 LED be on while the PLC still reads OFF?
    Compare the switched output voltage at the sensor with the voltage at the input terminal, both relative to the correct common. A local LED does not prove cable continuity, the input return path or the configured PLC address. Check those stages separately before replacing the sensor.
  • How should II5910 distinguish a passing target from a permanently nearby metal bracket?
    Check the target-absent state after final mounting, with the bracket and surrounding machine metal in their normal positions. Then move the intended target through its full path. A continuously active output before the target arrives requires a mounting or target-clearance review, not an input inversion to conceal the condition.
  • What changes when II5910 detects a stainless-steel replacement target?
    The stainless-steel correction factor is 0.7 relative to steel. Re-establish the working clearance using the actual replacement target and repeat approach and withdrawal tests; do not retain a clearance qualified only with mild steel.
  • Why can II5910 detect slow movement but miss the same target at operating speed?
    The input filter, bus update and program sampling can reject a short pulse even when the sensor switches. Measure pulse duration at the receiving input and compare it with the complete acquisition path. Test at maximum intended speed and minimum target spacing, rather than accepting a static LED check.
  • How can load-related II5910 protection cycling be separated from unstable target detection?
    Hold a suitable target stationary inside a reliable sensing margin. Check supply stability and the connected load. Pulsing that disappears when a verified compatible test load replaces the field circuit points to wiring or load conditions; pulsing tied to physical movement calls for a sensing-margin investigation.
  • What should be measured before sharing the II5910 supply with the receiving input?
    Verify that both devices permit the chosen supply and common arrangement. Measure voltage at the sensor under load, then confirm that the ON voltage at the receiver exceeds its specified input threshold after sensor and cable drops. A nominal 24 V supply marking alone does not establish this margin.
  • How should II5910 repeatability be checked after the mounting nuts are secured?
    Use the actual target and repeat its approach and withdrawal over several cycles. Record ON and OFF positions independently so hysteresis is not mistaken for erratic operation. Repeat after final cable support and mounting adjustment to reveal movement introduced during installation.
  • Does the II5910 MTTF value establish a permitted service interval or safety function?
    No. An MTTF figure is a reliability statistic, not a scheduled replacement interval or evidence of a safety-rated protective function. Maintenance intervals and any safety-related architecture must be established from the application requirements and applicable approvals.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.