Match the complete marking
Include 106765-04 and every suffix or approval code visible on the item. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request clear photos of the both cable ends for 106765-04. Have your maintenance team compare the offered reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 106765-04
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:106765-04
-
Weight:0.34 kg
-
Tariff Code:8537101190
-
Cable family:106765 Velomitor XA interconnect
-
Ordered length:4 m (04)
-
Ordering span:1–25 m; 3 m increments from 1 m
-
Cable lead size:0.382 mm² (22 AWG), per 106765 cable drawing
-
Identified leads:A white; B black; SHLD green
-
Protective construction:Stainless-steel armor over cable
-
Matching sensor family:330525 Velomitor XA
Information
- 106765-04 is part of the field signal route, so connector, length and shield treatment must be considered as one installation.
Associated equipment: 330525 Velomitor XA sensor
Ordered reach: 4 m
For installation, verify both connector ends and the required route before fitting the armored assembly. Protect the cable at entry points, maintain bend clearance and follow the installed control drawing for shield handling and hazardous-area boundaries.
If a signal becomes intermittent, isolate the loop and test continuity section by section before exchanging the sensor or transmitter. Retain the complete cable marking, route and termination record to make future fault isolation reproducible.
-
106765-04 technical reference
Original Bently Nevada technical data sheet excerpt, 10 pages. Ordering identity, interface and verified technical data. -
106765-04 engineering technical guide
Apter Power engineering field workflow, 2 pages. Verified interface data, installation checks, commissioning sequence and engineering questions.
Route planning: Confirm the ordered reach, connector orientation and field-wiring path against the machine drawing.
-
Sensor-to-monitor path
Carry the documented field signal along the installed route without changing connector assignments. -
Protected cable run
Route the armored construction where physical protection is needed, while controlling strain at both ends. -
Replacement planning
Compare complete part marking, length and end connections with the removed cable. -
Fault isolation
Inspect connectors and test conductor continuity with the channel isolated before replacing adjacent equipment.
Check the complete part number and length against the site drawing.
Verify connector fit, pin identity and visible damage before energizing.
Maintain clearance and strain relief along the selected route.
Follow the approved field wiring drawing; do not use armor as an assumed signal return.
Isolate the circuit and check each signal path before reconnecting.
Record cable length, path and channel result for future maintenance.
Alternative Names
Technical notes
Installation relationship: Confirm cable routing, connector engagement and installed channel wiring before return to service.
System boundary: Ratings for a complete sensing chain apply only when the selected components, target and monitoring channel match the manufacturer arrangement.
Technical reference: Bently Nevada 330525 Velomitor XA Piezo-velocity Sensor Datasheet, 141633 Rev. M.
FAQ View All FAQ
-
How should 106765-04 be matched to an installed Velomitor XA channel?Compare the installed 330525 sensor connector, cable length and terminal arrangement with the complete drawing. The 106765 family is documented for the XA sensor; verify both ends before energizing the monitor.
-
What checks help isolate an open conductor in 106765-04?With the channel isolated, check the identified A, B and shield paths end to end and inspect both connector ends. Compare the result with the installed wiring record before condemning the cable or sensor.
-
How should the armor and shield of 106765-04 be handled during routing?Protect the armored cable from abrasion and mechanical strain. Terminate the shield according to the installed sensor and monitor wiring drawing; do not assume the armor is a signal return.
-
What should be checked after replacing 106765-04 with a different ordered length?Reconfirm the installed cable route, connector fit and monitoring-channel setup. The 106765 family is ordered in 3 m increments from 1 m; verify the complete supplied code and fit before commissioning.
-
How is the weather-resistant connection around 106765-04 maintained?The 330525 XA sensor assembly is rated IP65/NEMA 4X only when properly installed with its mating extension cable. Verify connector engagement and any specified splash-resistant boot and clamps on the actual installation; confirm those accessories are included before relying on the enclosure rating.
-
Can 106765-04 be routed through a 106769 terminal housing?Bently Nevada lists the 106769 housing for terminating Velomitor XA sensor cabling to bulk field cable, with capacity for up to two sensor cables. Check the housing fitting option, terminal allocation and approved wiring drawing; the housing is a separate ordered item.
-
How does 106765-04 differ from 02173007 bulk cable in a replacement plan?106765-04 is an ordered armored interconnect assembly. The separate 02173007 bulk field cable is supplied without connectors or lugs. Confirm the required connector and termination arrangement before considering a bulk-cable route as a replacement.
-
What should be checked if the channel remains abnormal after fitting 106765-04?Measure the connected 330525 sensor supply and bias, then isolate the 106765-04 lead and shield paths for continuity. If the cable path is intact, review sensor mounting and monitor configuration against the baseline rather than assigning the fault to the cable alone.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.