200150-09-CN

General-Purpose Accelerometer
In Stock
Ships by Sunday, September 20
Fast Shipping Available

Product Describe:

Bently Nevada 200150-09-CN is a general-purpose accelerometer for Trendmaster monitoring systems. It converts machine-case acceleration into the signal used for vibration trending and condition assessment.

Ask our team:

Get a quick price for: 200150-09-CN
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 200150-09-CN

Technical specifications for 200150-09-CN

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    200150-09-CN
  • Estimated shipping dimensions:
    30x30x8.0cm
  • Weight:
    1.35 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Sensitivity:
    10.2 mV/(m/s2) (100 mV/g), +/-12%
  • Acceleration range:
    +/-245 m/s2 (+/-25 g)
  • Resonant frequency:
    >20 kHz
  • Amplitude linearity:
    +/-2%
  • Transverse sensitivity:
    7% maximum
  • Settling time:
    300 ms maximum
  • Mounting thread:
    3/8-24 female
  • Mounting torque:
    2.7 to 6.8 N m
  • Sensing design:
    Ceramic shear
  • Case material:
    316L stainless steel
  • Connector:
    5-pin, 1/2-20
  • Mounting adaptor option:
    3/8-24 to 3/4 NPT, 1-1/4 in hex

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 200150-09-CN is a general-purpose accelerometer for Trendmaster monitoring systems. It converts machine-case acceleration into the signal used for vibration trending and condition assessment.
  • Converts casing acceleration into an IEPE-compatible electrical signal
  • Supports general-purpose Trendmaster vibration measurements
  • Uses a ceramic-shear sensing element in a stainless-steel case
  • Accepts the configured threaded mounting adaptor

200150-09-CN installs with Trendmaster 2000 or Trendmaster Pro channel, compatible accelerometer interface cable, threaded machine mounting point, approved signal-conditioning input in an engineered Trendmaster 2000 and Trendmaster Pro configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this general-purpose accelerometer.

Important Notice: Confirm the complete 200150-09-CN marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power 200150-09-CN Manuals and Guides
Apter Power 200150-09-CN Product Technical Reference PDFBently Nevada 200150-09-CN Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Machine-case vibration trendingConverts casing acceleration into an IEPE-compatible electrical signal
Motor bearing-housing monitoringSupports general-purpose Trendmaster vibration measurements
Pump condition monitoringUses a ceramic-shear sensing element in a stainless-steel case
Fan and gearbox acceleration measurementAccepts the configured threaded mounting adaptor
Read the applicable Bently Nevada installation instructions before work. Verify 200150-09-CN and the installed Trendmaster 2000 and Trendmaster Pro configuration.
1Confirm the full 200150-09-CN marking and mounting adaptor before installation.
2Isolate the connected monitoring input before cable work.
3Prepare a flat, clean mounting surface and avoid paint or debris beneath the adaptor.
4Apply the published mounting torque without twisting the sensor cable.
5Protect the five-pin connector from moisture and conductive contamination.
6Route the interface cable away from high-current conductors and sharp bends.
7Verify settled bias and a stable noise floor before accepting measurements.
8Record the new vibration baseline after installation.

Technical notes

Technical notes

Mount 200150-09-CN on a clean, rigid surface using the configured adaptor and published torque, then verify connector seating, bias condition and signal polarity before collecting baseline vibration data.

FAQS

  • What must be matched before replacing 200150-09-CN?
    Match the complete 200150-09-CN marking, general-purpose accelerometer, installed mounting or connector execution and the approved equipment record before removal.
  • Which system components should be checked with 200150-09-CN?
    Confirm the installed Trendmaster 2000 or Trendmaster Pro channel, compatible accelerometer interface cable and the assigned monitoring or connection point are the documented combination for 200150-09-CN.
  • How should wiring or cabling for 200150-09-CN be recorded?
    Record conductor identity, shield termination, connector orientation, cable route and the as-found diagnostic state before disconnecting 200150-09-CN.
  • What installation control is important for 200150-09-CN?
    Use the model-specific mounting arrangement, protect mating surfaces and maintain the documented cable support and mechanical clearance for 200150-09-CN.
  • How is 200150-09-CN checked during commissioning?
    Apply the approved controlled test for machine-case vibration trending, verify polarity or direction where applicable, and compare the measured response with the configured channel.
  • Can parameters from a similar model be used for 200150-09-CN?
    No. Retain only values and configuration details that apply directly to the complete 200150-09-CN ordering code and installed system.
  • What maintenance evidence should be retained for 200150-09-CN?
    Retain the full 200150-09-CN identity, as-left mounting and connections, continuity or bias checks, diagnostics and the final functional-test result.
  • What should be verified before returning 200150-09-CN to service?
    Confirm secure mounting, connector integrity, restored configuration, stable signal behavior and the intended response of the associated monitoring channel.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.