Match the complete marking
Include 16710-99 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 16710-99 reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 16710-99
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:16710-99
-
Weight:2.45 kg
-
Tariff Code:8537101190
-
Cable function:Accelerometer interconnection
-
Selected length:99 ft
-
Conductor count:3 conductors
-
Conductor size:22 AWG (0.5 mm2)
-
Cable construction:Shielded and armored
-
Transducer connector:3-socket plug
-
Monitor end:Terminal lugs
-
Armor material:Flexible stainless steel
-
Approximate armored diameter:7 mm shown in the wiring figure
-
Conductor A:White
-
Conductor B:Red
-
Conductor C:Black
-
Shield lead:Green
-
Orderable length range:3 to 99 ft
-
Length increment:1 ft
-
Supported sensor context:330400/330425 accelerometers and 330450 system
Information
- Bently Nevada 16710-99 is a 99 ft armored three-conductor interconnection cable for accelerometer monitoring channels.
Signal construction: 3-conductor shielded 22 AWG cable in flexible stainless-steel armor.
Termination: 3-socket plug to terminal lugs; A/B/C and shield conductors identified by color.
The three 22 AWG conductors are shielded and protected by flexible stainless-steel armor. The wiring figure identifies A white, B red, C black and a green shield lead; preserve this mapping and the installed shield termination during replacement.
Acceptance combines cable and channel evidence: inspect the three-socket plug, route and armor, prove conductor continuity with the channel isolated, then verify the returned accelerometer output and monitor response against the established baseline.
-
Bently Nevada 16710-99 official technical excerpt
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
Bently Nevada 16710-99 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below require the documented 330450 high-temperature acceleration system cabling companion components and approved machine drawing.
-
Installed signal path
Connect the documented accelerometer to its assigned high-temperature acceleration-system monitoring input. -
Condition-monitoring service
Use the cable only with the documented transducer and monitor or conditioner family assigned to the machine channel. -
Maintenance replacement
Match conductor count, connector, length, armor and routing before disturbing the installed cable. -
Channel acceptance
Prove continuity, insulation condition and returned channel response against the approved machine baseline.
Match 16710-99, cable length, connector and conductor construction with the installed record.
Place the monitor channel and machine in the approved maintenance state before disconnecting or checking continuity.
Keep contacts dry and clean; do not use the connector or terminal lugs as a pulling point.
Preserve bend clearance, armor support, abrasion protection and separation from damaging heat or sharp edges.
Label each conductor and shield before removal, then compare end-to-end continuity with the applicable wiring drawing.
After reconnection, verify the expected monitor indication and operating response before return to service.
Alternative Names
Technical notes
Signal relationship: The three-conductor shielded path connects the 330400/330425 accelerometer context to the assigned monitoring electronics.
Wiring relationship: Preserve A/B/C conductor identity, shield termination and independent armor support through the 99 ft route.
Technical reference: Bently Nevada 330450 High Temperature Acceleration System Datasheet, 169885 Rev. H.
FAQ View All FAQ
-
Which sensor system context applies to 16710-99?Use the cable only where the installed record identifies the applicable 330400/330425 accelerometer and 330450 high-temperature acceleration-system channel.
-
How should conductor identity be preserved on 16710-99?Before removal, label the A white, B red, C black and green shield paths at the terminal-lug end and compare them with the approved wiring drawing.
-
What connector inspection is required for 16710-99?Inspect the three-socket plug for moisture, contamination, looseness and contact damage; provide route support so the connector carries no cable load.
-
How should the shield and armor of 16710-99 be treated?Preserve the documented shield termination and support the flexible stainless-steel armor independently; neither armor nor shield should be reassigned without the applicable drawing.
-
What continuity test is appropriate for 16710-99?With the system isolated, test each conductor end to end and check for unintended conductor-to-shield paths using the approved site method.
-
What routing evidence is needed for 16710-99?Record bend clearances, armor support, heat exposure, abrasion protection and separation from sources that could damage or contaminate the cable.
-
How is channel polarity verified after installing 16710-99?Reconnect A/B/C and shield according to the documented drawing, then compare the accelerometer output and monitor indication with the accepted baseline.
-
What handover data should accompany 16710-99?Retain the complete marking, conductor map, connector inspection, continuity results, as-left route photographs and controlled channel-response result.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.