Match the complete marking
Compare DO801 3BSE020510R1 with the installed label and applicable ABB documentation.
-
Check the offered item before ordering
Request photos of the offered DO801 3BSE020510R1 and compare markings, interfaces and included items with the installed unit.
Technical specifications for DO801 3BSE020510R1
-
Manufacturer:ABB
-
Product Category:DCS Systems
-
Spare Part Number:DO801 3BSE020510R1
-
Weight:0.2 kg
-
Tariff Code:8537101190
-
Equipment role:16-Channel Digital Output Module
-
System context:ABB S800 I/O
-
Article number:3BSE020510R1
-
Channels:16
-
Signal:24 V DC (12–32 V DC)
-
Output current:0.5 A
-
Output execution:Current sourcing and current limiting
-
Isolation:One group of 16, isolated from ground
-
Output supervision:Status indicators and OSP predetermined state
-
Protection:Short-circuit, overvoltage and overtemperature
-
Mechanics:S800L
-
Cable length:600 m maximum
-
Rated insulation:50 V
-
Dielectric test:500 V AC
-
Power dissipation:2.1 W typical
-
ModuleBus current:80 mA at 5 V
-
Output driver:Protected high-side driver per channel
-
Output load:< 0.4 ohm
-
Short-circuit limit:Protected to ground and 30 V
-
Connection:Detachable process and power connectors
-
Inductive load suppression:Integrated per output channel
-
Channel indication:Output-state LED per channel
-
Optical isolation:Optical barrier in each output channel
-
RoHS compliance:EU RoHS, UAE RoHS and China RoHS
-
WEEE compliance:Directive 2012/19/EU
Information
- DO801 3BSE020510R1 occupies a defined service position in the ABB S800 I/O; selection depends on the complete marking and installed boundary.
Fault handling: Current limiting combines with short-circuit, overvoltage and overtemperature protection.
Safe state: OSP drives the outputs to a predetermined state after a communication error.
Within the ABB S800 I/O, evaluate this item together with its carrier, terminals, cables and project or hardware settings. Preserve the as-found interface map and revision evidence; a mechanically similar item is not automatically equivalent.
Commissioning should progress from identity and connection checks to controlled power-up, diagnostics and functional proof. Keep the final status, test conditions and open exceptions in the handover record.
-
ABB S800 I/O Official Outline
Official ABB document - PDF. DO801 article number, channel, signal and S800 I/O technical data. -
DO801 3BSE020510R1 Installation & Commissioning Guide
Apter Power engineering guide - PDF, 5 pages. Replacement sequence, commissioning checks, diagnostics and acceptance evidence.
Compatibility boundary: Match the complete marking, hardware execution and installed interfaces before replacement.
-
Installed-system replacement
Compare the exact code, host position and connected interfaces with the removed item. -
Planned maintenance
Capture the as-found label, status and configuration before disturbing the installation. -
Controlled commissioning
Restore documented connections and prove the intended signal, communication or control response. -
Spare qualification
Keep revision, configuration and acceptance evidence with the spare-part record.
Check every token in DO801 3BSE020510R1 against the offered label and approved record.
Follow the site procedure for stored energy, field power and electrostatic handling.
Photograph and label carriers, terminals, cables and keying before removal.
Archive applicable ABB S800 I/O settings before replacement.
Check connectors, terminal blocks, carriers and cable condition before blaming the module.
Use an approved functional test and retain as-left diagnostic and acceptance evidence.
Alternative Names
Technical notes
Pre-purchase checks: Match the offered DO801 3BSE020510R1 nameplate, article number and hardware execution with the installed S800 I/O record and terminal arrangement.
Terminal-unit and field pairing: Verify the exact terminal unit, 24 V DC field supply, channel wiring and output grouping before energization. The module has 16 current-sourcing outputs with one isolated group; a terminal unit mentioned in technical information is not automatically included in the supply.
Quotation confirmation: Confirm available quantity, estimated dispatch date, lead-time starting event, included items and documents in writing. Country of origin: Sweden. Condition: New, original product. Supply scope: Confirmed in quotation.
FAQ View All FAQ
-
How should DO801 3BSE020510R1 be identified before a replacement is approved?Compare every token in the complete marking, installed position and documented 16-channel digital output module role. Confirm the physical label before approval.
-
What evidence should be retained before removing DO801 3BSE020510R1?Record the mounting position, connected interfaces, status indications and current ABB S800 I/O configuration. Photograph the complete label before disconnection.
-
How should the interfaces for DO801 3BSE020510R1 be checked during installation?Map each connector, terminal and cable to the as-found record and applicable manufacturer documentation. Preserve keying and shielding arrangements.
-
What configuration boundary matters when commissioning DO801 3BSE020510R1?Use the approved ABB S800 I/O record and exact hardware execution. Physical fit alone does not prove configuration or interface equivalence.
-
How can a suspected DO801 3BSE020510R1 fault be separated from wiring or carrier faults?Verify supply and reference conditions, then inspect mating hardware and external wiring. Use controlled substitution only after both signal paths are documented.
-
What should be verified after fitting DO801 3BSE020510R1?Confirm normal indications, communication or signal continuity and the intended controlled-system response under an approved test state.
-
Can DO801 3BSE020510R1 be replaced by a similar-looking assembly?No direct equivalence is established by appearance. Compare the complete code, revision, interface execution and installed configuration.
-
What handover record is appropriate after work on DO801 3BSE020510R1?Retain offered and removed markings, connection photographs, configuration evidence, diagnostics, functional-test results and unresolved exceptions.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.