Product Describe:
ABB PHARPSPEP11013 is a Harmony HR Series MPS 3 power entry panel for one chassis, with 120/240 VAC main input and 120/240 VAC auxiliary input documented by ABB.
ABB PHARPSPEP11013 is a Harmony HR Series MPS 3 power entry panel for one chassis, with 120/240 VAC main input and 120/240 VAC auxiliary input documented by ABB.
Dual AC entry: Accepts the documented main and auxiliary 120/240 VAC inputs.
Single-chassis support: Feeds the documented one-chassis Harmony modular power arrangement.
Power-system integration: Interfaces the incoming AC circuits with the HR Series MPS 3 assembly.
Category III duty: Matches the documented installation-category requirement for the panel.
Treat PHARPSPEP11013 as the complete panel identity. Confirm the single-chassis architecture, both AC input circuits and the associated Harmony power-system components before energization.
Important Notice: Confirm the complete ABB PHARPSPEP11013 identity and controlled configuration before commissioning.
The first document presents model-specific technical and system data. The second provides a separate installation, connection, commissioning and acceptance workflow.
Harmony chassis power
Provides the documented AC entry for a single Harmony chassis.
Main and auxiliary feeds
Separates and identifies the two approved 120/240 VAC input paths.
MPS 3 maintenance
Supports controlled replacement within an HR Series MPS 3 power assembly.
Power restoration
Requires verification of both input circuits before the chassis returns to service.
Read the applicable ABB instructions before work. Verify ABB PHARPSPEP11013 and the installed system configuration before commissioning.
1
Verify the complete ABB PHARPSPEP11013 marking before work.
2
De-energize and verify both main and auxiliary AC sources.
3
Confirm the installation is the documented single-chassis arrangement.
4
Record every input conductor, protective device and terminal position.
5
Maintain the documented Category III installation boundary.
6
Inspect the associated Harmony power-system components before connection.
7
Verify main and auxiliary inputs independently before full energization.
8
Record final voltage checks and chassis status before release.
Technical notes