Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 6AG1195-7HD10-2XA0
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 6AG1195-7HD10-2XA0

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6AG1195-7HD10-2XA0
  • Estimated shipping dimensions:
    9.7x9.2x3cm
  • Weight:
    0.13 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    GERMANY
  • Input Voltage Type:
    24 V DC routed via the active backplane bus connection
  • Ambient Operating Temperature:
    -40°C to +70°C
  • Storage and Transport Temperature:
    -40°C to +70°C
  • Relative Humidity:
    5% to 95% relative humidity
  • Chemical Resistance:
    ISA-S71.04 severity level G1, G2, G3 compliant for aggressive environment durability

Information

Overview Manuals Common Applications Product Precautions
The 6AG1195-7HD10-2XA0 is a Siemens SIPLUS ET 200M extended active bus module. It is an industrial-grade ruggedized product primarily used to support hot-swapping and redundant configuration of PROFIBUS-DP systems.
    • Conformal coated for anti-corrosion resilience
    • Wide range from -40°C to +70°C (-40°F to 158°F)
    • Supports system startup at -25°C (-13°F)
It features conformal coating for extreme environments (Class 3C4/3B2), operating in temperatures from -40°C to +70°C, and supports altitudes up to 5,000 meters. Engineered for zero-downtime, this module is ideal for critical infrastructure and severe industrial conditions. As a high-availability foundational component within the SIMATIC S7-300 and ET 200M distributed I/O framework, this active bus module provides a ruggedized physical and electrical backbone for dual redundant IM 153-2 interface modules. By utilizing its integrated active backplane routing, the hardware allows the secondary communication link to take over the PROFIBUS DP network throughput seamlessly if the primary channel experiences a sudden interruption. This advanced electrical continuity enables hot-swapping or the removal and insertion of peripheral modules under run mode, guaranteeing that critical processing operations proceed without a single second of unexpected plant shutdown.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 Siemens 6AG1195-7HD10-2XA0 Active Bus Module Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Oil & Gas
Applied in distributed I/O systems for offshore drilling rigs and arctic oilfields. It ensures continuous data acquisition for production control systems under extreme low temperatures and high salt spray environments.

Refining & Petrochemicals
Installed in refinery control cabinets exposed to high concentrations of corrosive gases. Its conformal coating (Class 3C4) prevents chemical corrosion on circuit boards, ensuring intrinsic safety and process control.

Wind Power Generation
Installed within the towers and nacelles of offshore or high-altitude wind turbines. It copes with severe temperature fluctuations and condensation inside the nacelle, ensuring stable communication for wind turbine yaw and pitch control systems.

Rail Transit
Used in outdoor wayside signaling cabinets, station Building Automation Systems (BAS), or locomotive controls. It resists strong mechanical vibrations and the risk of electrical short circuits caused by humid, condensing underground environments.

Chemical Pharmaceuticals
Provides robust PLC control in complex batching areas surrounding cleanrooms or special control environments requiring frequent chemical disinfection with volatile chemical substances.

 When utilizing the 6AG1195-7HD10-2XA0 module, ensure the operating environment rigorously strictly strictly stays within its Class 3C4 chemical resistance specifications and wide-temperature limits. For active hot-swapping during RUN mode, it must be paired explicitly with compatible ET 200M interface modules (e.g., IM 153-2) and active bus rails, ensuring the mechanical latches are securely locked. All wiring must comply with Siemens EMC standards, utilizing large-surface grounding and shielded cables to suppress high-frequency EMI, alongside routine inspections for dust accumulation to sustain long-term high reliability.

FAQ View All FAQ

  • What exactly is the product 6AG1195-7HD10-2XA0?
    It is an industrial-grade active distributed backplane bus extension module manufactured by Siemens.
  • What is the official core Siemens product line that this module belongs to?
    It belongs to the SIPLUS extreme ruggedized product family by Siemens, which is a deeply hardened upgrade based on the standard SIMATIC S7-300 and ET 200M system hardware.
  • How do you use an active bus module product like 6AG1195-7HD10-2XA0?
    It must first be snapped horizontally onto a dedicated active rail so that adjacent bus modules snap together physically, then two redundant IM 153-2 communication interface modules are inserted vertically on its front face.
  • What is the core purpose of 6AG1195-7HD10-2XA0 in a distributed network?
    It is primarily used to provide active backplane bus bridging and slotting supports for dual interface modules, thereby assisting remote distributed slave racks in achieving high-reliability hardware redundancy over PROFIBUS DP.
  • Why is it necessary to extra use the 6AG1195-7HD10-2XA0 active module in Siemens automation racks?
    It must be installed when the distributed rack requires the replacement of faulty signal modules without system shutdown, or when a primary-backup redundant communication link is required to prevent unexpected downtime.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.