With more than 30.000 high-quality spare parts, they can be sold immediately. Our large inventory allows us to quickly meet customer needs, thereby reducing downtime and protecting production schedules. Our timely delivery time provides you with security and save money.
The 6ES7193-6AR00-0AA0 is a dedicated BA 2xRJ45 BusAdapter engineered for the SIMATIC ET 200SP system and S7-1500 compact CPUs. Packing two standard 100 Mbps RJ45 industrial Ethernet ports into a compact 20mm form factor, it plugs directly into the interface module (IM) body to serve as a physical medium conversion hub.
Network ports separate from the IM body; independent replacement prevents dismantling host electronics
Links multiple remote stations via copper cables (Cu), supports line and MRP ring topologies up to 100 m
Runs at -30°C to 60°C (horizontal) or -30°C to 50°C (vertical) inside enclosures
It is a hardware component used for physical medium conversion in industrial automation networks. Within distributed control systems and industrial Ethernet network architectures, this hardware converts underlying proprietary communication contacts into industry-standard dual-port physical links. At the configuration layer of network topologies and physical interfaces, this adapter integrates one PROFINET interface and extends out two standard RJ45 ports with a built-in switch function at the hardware level.
This multi-port configuration allows multiple distributed remote stations to be organized into a daisy-chain linear topology via standard copper twisted-pair cables (Cu conductors) without introducing external industrial switches, with a maximum physical data transmission distance of up to 100 meters between any two nodes. Fully supporting the PROFINET IO communication protocol, this BusAdapter ensures deterministic data exchange and provides a transparent data transmission pathway for plant-wide distributed control systems.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Siemens 6ES7193-6AR00-0AA0 Bus Adapter Manuals, Datasheets, Drivers, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Lithium Battery Manufacturing
Deployed in cell filling, high-temperature aging rooms, and dry process workshops, leveraging its extreme dryness resistance (dew point -60°C) to safely and stably connect distributed I/O stations to the main control network.
Semiconductor Manufacturing
Used inside cleanroom automated material handling systems (OHT/AMR) and ultra-pure water control enclosures, leveraging its ultra-compact 20 mm form factor to implement daisy-chain network interconnection without taking up extra DIN rail space.
Automotive Manufacturing
Applied in body welding, stamping, and final assembly assembly lines. If a field RJ45 port is damaged by frequent maintenance or heavy mechanical vibration, it allows for low-cost, independent replacement without dismantling the entire interface module.
Rail Transit
Used in high-voltage cable utility tunnels and ventilation BAS control boxes along subways, utilizing its industrial wide-temperature range of -30°C to 60°C and passive backplane powering to stably transmit PROFINET IO signals over long distances.
Wind Power Generation
Installed inside tower and nacelle control cabinets of wind turbines located in high-altitude mountainous or plateau regions, its hardware design supports an installation altitude of up to 5,000 meters to ensure high-frequency distributed data acquisition.
The Siemens 6ES7193-6AR00-0AA0 is a dedicated BA 2xRJ45 BusAdapter for the SIMATIC ET 200SP system. It converts underlying proprietary communication contacts into two standard 100 Mbps RJ45 ports with a built-in switch function, achieving mechanical separation between the network ports and the host electronics module to allow independent, low-cost replacement if a port is damaged.
Fully supporting the PROFINET IO protocol, it enables daisy-chain linear topologies and MRP ring redundancy with a maximum transmission distance of up to 100 meters per segment. This passive backplane-powered unit provides 707V DC electrical isolation, operates across a wide temperature range of -30°C to 60°C, and runs at altitudes up to 5,000 meters with an absolute humidity resistance down to a dew point of -60°C for dry rooms, backed by an official EPD verification featuring 0 kg operational carbon emissions.
During operation, live hot-swapping is strictly prohibited, and pairing it with IE FC RJ45 Plug 180 fast-connect plugs is highly recommended to ensure secure shield grounding. Moreover, strict derating specifications must be followed for high-altitude or vertical installations (max 50°C), and correct ring roles must be configured in TIA Portal when organizing an MRP ring to prevent network storms.
This adapter achieves mechanical decoupling between the communication interfaces and the electronics module, allowing for low-cost, independent replacement of a damaged network port without dismantling the entire distributed station. Featuring built-in dual-port physical layer chips, it enables "daisy-chain" linear network topologies and MRP media redundancy without requiring external switches. Furthermore, it delivers 707V DC electrical isolation and stable industrial wide-temperature operation from -30°C to +60°C, establishing it as an efficient, flexible, and maintainable uplink interconnection hardware in modern distributed PROFINET networks.
It is a dedicated BA 2xRJ45 BusAdapter for the Siemens SIMATIC ET 200SP distributed I/O system and S7-1500 compact CPUs. It plugs into the distributed interface module (IM) to provide two standard 100 Mbps RJ45 physical network ports.
What is the core purpose of the 6ES7193-6AR00-0AA0 product?
Its core purpose is to achieve mechanical separation between the communication ports and the electronics module. Serving as a physical medium conversion hub for PROFINET networks, it securely and stably connects remote I/O stations to the industrial Ethernet backbone.
How should the 6ES7193-6AR00-0AA0 be correctly used and installed?
Align its rear dedicated pins with the slot on the bottom right of the ET 200SP interface module (such as IM 155-6PN), push it horizontally until the latch locks, tighten the front retaining screw, and finally insert standard industrial RJ45 network plugs.
What is the greatest technical advantage of using the 6ES7193-6AR00-0AA0?
The greatest advantage is significantly lower maintenance costs. When field RJ45 ports are damaged by frequent swapping or vibration, maintenance personnel only need to replace this adapter individually without replacing the entire expensive interface module (IM) body.
What network topologies does the 6ES7193-6AR00-0AA0 support?
Featuring a built-in dual-port switch chip, this adapter supports chaining multiple distributed stations in a linear topology (daisy-chain), or forming an MRP (Media Redundancy Protocol) ring network with self-healing capabilities against cable breaks.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.