Match the complete marking
Include 6ES7407-0KA01-0AA0 and the visible revision or assembly identity in your enquiry. Keep the complete reference on the quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 6ES7407-0KA01-0AA0 with the installed equipment and applicable Siemens documentation.
Technical specifications for 6ES7407-0KA01-0AA0
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6ES7407-0KA01-0AA0
-
Weight:2.5353 lbs (1.15 kg)
-
Tariff Code:8537101190
-
Product type:PS 407 10A
-
System:SIMATIC S7-400
-
Rated AC input:120/230 V AC
-
Permitted AC input:85-264 V AC
-
Rated DC input:110/230 V DC
-
Permitted DC input:88-300 V DC
-
Frequency:50/60 Hz rated; 47-63 Hz permitted
-
Output voltages:5.1 V DC and 24 V DC
-
Output currents:10 A on the 5 V circuit; 1 A on the 24 V circuit
-
Protection class:Class I; protective conductor required
-
Overvoltage category:II
-
Pollution degree:2
Information
- Siemens 6ES7407-0KA01-0AA0. A PS 407 replacement affects both rack power and backup supervision; record the existing power and battery arrangement before removal.
System: SIMATIC S7-400
Rated AC input: 120/230 V AC
Permitted AC input: 85-264 V AC
Secondary circuits provide nominal 5.1 V DC and 24 V DC, rated at 10 A for the 5 V circuit and 1 A for the 24 V circuit. Budget the two circuits separately. The standard PS 407 10A must remain distinct from the PS 407 10A R redundant execution.
The module is protection class I and requires the protective conductor. The standby switch does not disconnect the incoming supply; safe replacement requires upstream isolation. Retain the backup-battery and battery-monitoring configuration, then verify supply indications and rack startup against the approved system record.
-
Siemens 6ES7407-0KA01-0AA0 technical reference
Original manufacturer excerpt - PDF, 3 pages. PS 407 10A function, supply limits, output ratings and operator controls. -
Siemens 6ES7407-0KA01-0AA0 installation guide
Prepared by Apter Power - PDF, 5 pages. Installed-system review, configuration checks, commissioning and handover.
Configuration scope: Technical values apply to the complete 6ES7407-0KA01-0AA0 execution. Retain the actual installed configuration and applicable Siemens instructions.
-
S7-400 rack replacement
Use the PS 407 10A as the documented rack-power execution. Match the complete order number and keep the standard unit distinct from the redundant execution. -
AC supply cabinets
Plan AC input wiring, protective conductors and upstream isolation around the installed cabinet supply. Verify the specified voltage and frequency limits before energizing. -
DC distribution systems
Check the installed DC network against the PS 407 input range. Use the prescribed connector and wiring arrangement, with the approved upstream isolation procedure. -
Power and backup service
Review secondary loading and the installed battery-monitoring arrangement during service. Confirm power indications and rack startup before restoring the controller to operation.
The rated AC input is 120/230 V, with a permitted range of 85-264 V AC and a frequency range of 47-63 Hz.
Rated DC input is 110/230 V, with a permitted range of 88-300 V DC. Use the prescribed power connector and wiring procedure.
The supply provides 5.1 V DC and 24 V DC. The current ratings are 10 A for the 5 V circuit and 1 A for the 24 V circuit.
The standby switch does not disconnect the incoming supply. Use the appropriate upstream isolation before replacement.
It is protection class I with protective conductor. Preserve the approved protective-earth connection and enclosure bonding.
This order number identifies the standard PS 407 10A. The redundant PS 407 10A R is a separate execution.
Alternative Names
Technical notes
System relationship: A PS 407 replacement affects both rack power and backup supervision; record the existing power and battery arrangement before removal.
Configuration boundary: Record the incoming supply, backup batteries, battery-monitoring selection and rack startup condition. After replacement verify supply indications and the approved controller startup sequence.
Technical reference: Siemens S7-400 Automation System Module Data, A5E00850736-AK, 09/2021. Technical values apply to the complete 6ES7407-0KA01-0AA0 execution. Retain the actual installed configuration and applicable Siemens instructions.
FAQ View All FAQ
-
Which AC supply range can feed 6ES7407-0KA01-0AA0?The rated AC input is 120/230 V, with a permitted range of 85-264 V AC and a frequency range of 47-63 Hz.
-
Can 6ES7407-0KA01-0AA0 operate from DC input?Yes. Rated DC input is 110/230 V, with a permitted range of 88-300 V DC. Use the prescribed power connector and wiring procedure.
-
What secondary circuits does 6ES7407-0KA01-0AA0 supply?The supply provides 5.1 V DC and 24 V DC. The current ratings are 10 A for the 5 V circuit and 1 A for the 24 V circuit.
-
Does the standby switch isolate the input of 6ES7407-0KA01-0AA0?No. The standby switch does not disconnect the incoming supply. Use the appropriate upstream isolation before replacement.
-
Is a protective conductor required for 6ES7407-0KA01-0AA0?Yes. It is protection class I with protective conductor. Preserve the approved protective-earth connection and enclosure bonding.
-
Is 6ES7407-0KA01-0AA0 the redundant PS 407 10A R execution?No. This order number identifies the standard PS 407 10A. The redundant PS 407 10A R is a separate execution.
-
How should the two output loads of 6ES7407-0KA01-0AA0 be checked?Budget the 5 V and 24 V circuits independently. Verify the actual rack, CPU, interface and I/O loads against both current ratings.
-
What should be retained when replacing 6ES7407-0KA01-0AA0?Record the incoming supply, backup batteries, battery-monitoring selection and rack startup condition. After replacement verify supply indications and the approved controller startup sequence.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.