Speak to a sourcing specialist
sales13@apterpower.com

6ES5470-4UC12

Analog Output Module
Ships by Friday, November 6
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Siemens 6ES5470-4UC12 is an eight-channel SIMATIC S5 analog output module with 1–5 V and 4–20 mA outputs.
  • Manufacturer part number
    6ES5470-4UC12
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    1.9cm ×19.2cm ×25.4cm
  • Country of Origin
    Germany
Get a quick price for 6ES5470-4UC12
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full 6ES5470-4UC12 marking and installed SIMATIC S5 configuration.
  • 1

    Confirm the offer

    Review the exact assembly, condition, included items and quoted dispatch date.
  • 2

    Arrange dispatch

    Confirm delivery details for 6ES5470-4UC12; tracking follows when shipment is arranged.
  • Match the complete marking

    Include 6ES5470-4UC12 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 6ES5470-4UC12 with the installed equipment and applicable Siemens documentation.

Technical specifications for 6ES5470-4UC12

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6ES5470-4UC12
  • Weight:
    0.48 kg
  • Tariff Code:
    8537101190
  • System family:
    SIMATIC S5
  • Module function:
    Analog output
  • Output channels:
    8
  • Voltage output range:
    1–5 V
  • Current output range:
    4–20 mA, parallel with voltage output
  • Value representation:
    12-bit two's complement
  • Nominal command scale:
    0–1024 units for 4UC variant
  • Output delay:
    ≤1 ms after data transfer
  • Voltage-mode load:
    ≥3.3 kΩ; maximum output current 3 mA
  • Current-mode load:
    ≤300 Ω
  • Operating error:
    ±0.6% over 0–60 °C
  • Capacitive load:
    <100 nF including line capacitance

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Siemens 6ES5470-4UC12 converts controller output values into continuous process signals. Its voltage and current connections require the corresponding load and reference-potential arrangement.
Product type: Analog output module
Output channels: 8
Signal ranges: 1–5 V and 4–20 mA
The 6ES5470-4UC12 belongs to the SIMATIC S5 470 analog output family. Its eight channels provide 1–5 V and 4–20 mA in parallel, with a nominal command representation of 0 to 1024 units. This range differs from the 470-4UA and 470-4UB variants, so the complete order code matters when preserving an existing process scale.

The output-value representation is 12-bit two's complement. The common 470 specification gives a delay of no more than 1 ms from data transfer to the analog output, and an operating error limit of ±0.6% over 0–60 °C. The eight outputs share the external reference Mext; isolation does not mean separate isolation between individual channels.

For voltage operation, the load resistance must be at least 3.3 kΩ and output current must not exceed 3 mA. Current-output loads must not exceed 300 Ω; the maximum no-load voltage is 18 V. Keep total capacitive loading below 100 nF and check the front-connector assignment, module enable and installed address before reconnecting process wiring.
Controller platform reference: SIMATIC S5. Match the installed configuration before replacement.
Technical downloads for 6ES5470-4UC12: an original Siemens reference excerpt and an Apter Power installation planning guide.
The 470-4UC12 output ranges apply to this order code; shared 470 module specifications retain their stated load and operating conditions. The planning guide is prepared by Apter Power; apply the complete manufacturer instructions and the stated applicability boundaries.
System and supply context: The 470-4UC12 output ranges apply to this order code; shared 470 module specifications retain their stated load and operating conditions. Accessories are included only when itemized in the quotation.

Platform applications: The following applications describe SIMATIC S5 functions. Match the complete 6ES5470-4UC12 identity to the installed system before selecting a replacement.
Prepare 6ES5470-4UC12 against the installed configuration and applicable Siemens instructions. Plan isolation and the resulting interruption of system operation before replacement.
Isolate the process

Place the machine in a safe state and isolate power before handling the module or front connector.

Preserve the variant

Use the complete 6ES5470-4UC12 reference; other 470 suffixes have different output ranges.

Check the load

Keep voltage loads at or above 3.3 kΩ and current loads at or below 300 Ω.

Respect the common reference

Check Mext and the front-connector wiring. The eight outputs are not individually isolated channels.

Retain configuration

Record the address and output scaling before removal; verify them against the installed S5 application.

Test under control

Apply controlled output commands and confirm the receiving equipment response before restoring normal operation.

Alternative Names

6ES5470-4UC12 Siemens 6ES5470-4UC12

Technical notes

Installation relationship: The output-value representation is 12-bit two's complement. The common 470 specification gives a delay of no more than 1 ms from data transfer to the analog output, and an operating error limit of ±0.6% over 0–60 °C. The eight outputs share the external reference Mext; isolation does not mean separate isolation between individual channels.

Configuration: The 470-4UC12 output ranges apply to this order code; shared 470 module specifications retain their stated load and operating conditions.

Technical reference: Siemens SIMATIC S5 analog input/output module instructions, C79000-B8576-C300-06.

FAQ View All FAQ

  • How many output channels does 6ES5470-4UC12 provide?
    It provides eight analog output channels with voltage and current output connections.
  • Which signal ranges apply to 6ES5470-4UC12?
    The 4UC12 variant provides 1–5 V and 4–20 mA in parallel; the nominal command scale is 0–1024 units.
  • How are output values represented by 6ES5470-4UC12?
    The module uses a 12-bit two's-complement representation. Preserve the installed program scaling.
  • What voltage-mode load is required for 6ES5470-4UC12?
    Use a load of at least 3.3 kΩ and observe the maximum voltage-output current of 3 mA.
  • What current-mode load can 6ES5470-4UC12 drive?
    The specified load resistance is no more than 300 Ω; maximum no-load voltage is 18 V.
  • How quickly does 6ES5470-4UC12 update its analog output?
    The specified delay between data transfer and analog output is no more than 1 ms.
  • Are the channels of 6ES5470-4UC12 individually isolated?
    The eight outputs use the common external reference Mext. Do not interpret the module isolation specification as individual channel isolation.
  • What accuracy condition applies to 6ES5470-4UC12?
    The operating error limit is ±0.6% over 0–60 °C. Correct load, wiring and scaling remain necessary.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.