Speak to a sourcing specialist
sales13@apterpower.com

6ES5451-4UA12

Digital Output Module
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Siemens 6ES5451-4UA12 switches 24 V DC field loads through 32 current-limited outputs. Four groups of eight have separate fusing and short-circuit indication.
  • Manufacturer part number
    6ES5451-4UA12
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    2cm x 19.5cm x 25.5cm
  • Country of Origin
    USA
Get a quick price for 6ES5451-4UA12
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 6ES5451-4UA12 reference, label photographs and required quantity. Check the enable-mode jumper, front connector coding and output-group fuses.

  • 1

    Confirm the offer

    Review the offered 6ES5451-4UA12 execution, condition and included items. Confirm output module, front connector and any separately quoted wiring accessories in the quotation.

  • 2

    Arrange dispatch

    Swift global dispatch. Confirm quantity, dispatch date and delivery details for 6ES5451-4UA12 in the quotation.

  • Match the complete marking

    Match the complete Siemens 6ES5451-4UA12 marking and actual installed configuration. Check the enable-mode jumper, front connector coding and output-group fuses.

  • Check the offered item before ordering

    Compare offered-unit photographs, interfaces and included items with the installed 6ES5451-4UA12 and its applicable installation requirements.

Technical specifications for 6ES5451-4UA12

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6ES5451-4UA12
  • Weight:
    0.46 kg
  • Tariff Code:
    8537101190
  • Digital outputs:
    32
  • Field supply range:
    20–30 V DC
  • Output current:
    5 mA to 0.5 A
  • Total current per eight outputs:
    4 A maximum
  • Group fuse:
    6.3 A slow, one per eight outputs
  • Off-state leakage:
    0.5 mA maximum
  • Resistive switching frequency:
    100 Hz maximum
  • Lamp load:
    5 W maximum
  • Backplane consumption:
    5 V, 120 mA typical

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Siemens 6ES5451-4UA12 connects the S5 output image to DC actuators while separating the backplane logic interface from the floating field-output group.
Fault localization: Short-circuit indication by eight-output group
Service interface: Enable input with selectable operating behavior
Load selection: Distinct resistive, inductive and lamp switching limits
The output stage is intended for DC loads such as contactors and solenoids. Although each output is current limited, the total current and fuse arrangement must also be evaluated for its eight-channel group.

The enable circuit affects how the module participates in the system. The -4UA12 version includes an enable-mode selection; preserve its actual setting and the associated field wiring when replacing an installed module.

Load type changes the permissible switching frequency. Inductive energy, lamp inrush and cabinet cooling must be evaluated against their respective limits, followed by a controlled channel-by-channel output test.
Controller platform reference: SIMATIC S5 U-series I/O. Follow the applicable installation instructions and approved design.
Technical and service documents for Siemens 6ES5451-4UA12, covering the applicable hardware arrangement and engineering verification.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
System and supply context: Siemens 6ES5451-4UA12 serves the SIMATIC S5 U-series I/O arrangement. Evaluate the full connected signal or control path when selecting companion hardware.

Application scope: The applications below describe the installed measurement or control path. Select compatible companion equipment; accessories are included only when expressly itemized.
Prepare Siemens 6ES5451-4UA12 for its configured installation using these checks.
Record group and enable allocation

Identify the four eight-output load groups, their fuses and their field-supply feeds. Record the module address and enable-mode jumper before disconnecting the front connector.

Check load duty and cabinet cooling

Review actual resistive, inductive and lamp loads separately. Add the currents in each output group and assess simultaneous loading against the available cabinet ventilation.

Restore the output interface

Place actuators in a safe maintenance state, isolate the relevant supplies and follow the S5 module replacement procedure. Reconnect the coded front connector and reinstate the recorded address and enable arrangement.

Test groups under controlled command

Command representative outputs individually before testing the required simultaneous state. Observe channel indications, group short-circuit indications and the physical release of each load.

Return the actuator sequence to service

Run the authorized sequence while observing interlocks and coil duty. Record the final fuse types, enable setting, affected output addresses and load checks for the maintenance handover.

Configuration handover

Retain the final 6ES5451-4UA12 identity, tested settings and accepted channel or system response for subsequent maintenance.

Alternative Names

Siemens 6ES5451-4UA12

Technical notes

Thermal diversity: Without forced ventilation, simultaneous-load diversity is reduced above 35 °C. Assess the cabinet conditions and aggregate output loading instead of relying solely on the individual-channel rating.

Inductive switching: The permitted inductive switching rate decreases with load current. Use the actual coil current and suppression arrangement in the switching-duty assessment.

Group fault response: A short-circuit indication identifies an output group. Isolate and investigate its field circuits before replacing the module or increasing protection ratings.

FAQ View All FAQ

  • Why can 6ES5451-4UA12 overheat even when no individual output exceeds its rated current?
    Group totals and simultaneous-load diversity still apply. Evaluate cabinet cooling and the number of energized outputs, especially without forced ventilation above 35 °C.
  • How does an inductive load affect the switching duty of 6ES5451-4UA12?
    The permitted rate is lower than for a resistive load and depends on coil current. Assess the actual coil and suppression circuit rather than using the resistive switching limit.
  • What does a group short-circuit indication on 6ES5451-4UA12 help isolate?
    It narrows the investigation to a group of eight outputs. Check the affected wiring, load and fuse before concluding that the entire module has failed.
  • Why should the enable-mode jumper on 6ES5451-4UA12 be photographed before removal?
    Its setting changes the enable-input behavior. Retaining the installed setting prevents a replacement from behaving differently despite identical output wiring.
  • Can a lamp circuit be selected for 6ES5451-4UA12 using steady-state current alone?
    No. Lamp inrush and the separate lamp-load rating must be considered in addition to the steady-state current.
  • Does current limiting on 6ES5451-4UA12 replace the specified group fusing?
    No. Current limiting and group fuses serve different functions. Preserve the specified protection arrangement and investigate the cause of a blown fuse.
  • How can an apparently inactive output on 6ES5451-4UA12 still influence a sensitive load?
    The off-state has finite leakage. Confirm that the load remains positively released at the permitted leakage level rather than treating an off command as an open circuit.
  • What should be checked when all outputs on 6ES5451-4UA12 remain inactive but the CPU is running?
    Check field supply, group protection, enable wiring and the selected address before changing the program. A running CPU alone does not establish a healthy field-output path.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.