Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 6ES5931-8MD11
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 6ES5931-8MD11

  • Manufacturer:
    Siemens
  • Product Category:
    General Automation
  • Spare Part Number:
    6ES5931-8MD11
  • Estimated shipping dimensions:
    4x20.5x25.5cm
  • Weight:
    0.9 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Romania
  • Supply designation:
    PS931
  • System family:
    SIMATIC S5
  • Supported installations:
    S5-95U / S5-100U / ET100U / ET200U
  • Rated AC input selections:
    115 V / 230 V AC
  • 115 V input operating range:
    92-132 V AC
  • 230 V input operating range:
    187-264 V AC
  • Rated input frequency:
    50/60 Hz
  • Input frequency range:
    47-63 Hz
  • Rated input current at 115 V:
    0.9 A
  • Rated input current at 230 V:
    0.6 A
  • Approximate efficiency:
    85%
  • Approximate power consumption:
    60 W
  • Rated DC output:
    24 V DC
  • DC output range:
    22.8-25.2 V DC
  • Rated output current:
    2 A
  • Horizontal arrangement ambient:
    0-60 C
  • Vertical arrangement ambient:
    0-40 C
  • Line-dip buffering duration:
    20 ms at 187 V input / 2 A output
  • Line-dip repetition interval:
    1 s
  • Output short-circuit response:
    Power limiting; electronic cutoff; non-latching
  • Fault LED:
    None
  • Protection class:
    Class I
  • Galvanic isolation:
    Yes
  • Stranded conductor capacity:
    2 x 0.5-1.5 mm2, with core-end sleeves
  • Solid conductor capacity:
    2 x 0.5-2.5 mm2
  • Insulation rating:
    VDE 0160; transformer VDE 0805
  • Rated insulation voltage, +24 V to L1:
    250 V AC
  • Insulation test voltage:
    2830 V AC
  • Typical module power loss:
    8.5 W
  • AC connection terminals:
    L1, N and protective earth
  • DC connection terminals:
    L+ and M
  • Mains selection:
    115 V / 230 V voltage selector
  • Mounting:
    Standard DIN mounting rail

Information

Overview Manuals Common Applications Product Precautions
Siemens 6ES5931-8MD11 is a PS931 power supply that converts a selected 115 V or 230 V AC input to 24 V DC at 2 A. The module supplies SIMATIC S5-95U/-100U and ET100U/ET200U installations.
  • Converts the selected AC line to the S5 DC supply
  • Separates line input from the L+ / M output circuit
  • Limits output short-circuit current electronically
  • Uses a rail-mounted enclosure with a protective terminal cover

Connect L+ and M to the corresponding S5-100U CPU terminals and retain the CPU grounding connection to the mounting rail. Keep the control, sensor and actuator supply circuits distinct in the installed wiring arrangement.

Important Notice: Check the voltage-selector position before energizing. External cable protection and the non-user-replaceable internal fuse serve different purposes; do not use the lack of a fault LED as proof of a healthy output.

Siemens 6ES5931-8MD11 Manuals & Downloads
Siemens 6ES5931-8MD11 Technical Reference (PDF)Siemens 6ES5931-8MD11 Manufacturer Manual Excerpt (PDF)

The first document organizes PS931 technical data and power-connection decisions. The second retains unchanged selected pages from the Siemens S5-100U system manual; it is a manufacturer manual excerpt, not the full manual.

S5-100U control power
Feeds the CPU supply terminals through the matched L+ and M connections.
S5-95U supply service
Provides the PS931 AC-to-DC supply role identified for the S5-95U installation.
ET100U / ET200U power
Supports the listed peripheral-system supply installations while retaining their existing wiring design.
Cabinet power distribution
Separates mains input and 24 V control distribution with coordinated line protection and grounding.
Read the applicable S5-100U instructions before work. Verify Siemens 6ES5931-8MD11, the mains-selector position, line protection and the installed 24 V supply circuit.
1
Isolate the AC supply before opening the protective terminal cover.
2
Set the voltage selector for the connected 115 V or 230 V supply.
3
Connect L1, N and protective earth to the supply-side terminals.
4
Retain L+ and M identities when reconnecting the CPU supply.
5
Select external line protection for the starting current and conductor.
6
Close the protective terminal cover before restoring mains power.
7
Retain the lower ambient limit when the PLC arrangement is vertical.
8
Verify the DC output after restoration; no dedicated fault LED is fitted.

Technical notes

Set the mains selector before connecting L1, N and protective earth; connect the 24 V output through L+ and M. Size external line protection for the selected mains supply, starting current and conductor; the internal fuse is not user-replaceable.

FAQ View All FAQ

  • Is PS931 automatically universal-input across both mains ranges?
    The unit has a voltage selector. Select the connected 115 V or 230 V supply before energizing; their operating ranges are 92-132 V and 187-264 V respectively. The two selections are not one continuous universal-input range.
  • What do the external line fuse and internal fuse protect?
    External protection is coordinated with the incoming cable so a short circuit does not overheat that cable. The internal fuse protects against a fault inside the module. One function does not replace the other.
  • Why should line protection not be chosen from the 0.9 A or 0.6 A steady input alone?
    Starting current is different from rated input current. The PS931 protection note gives 10 A at 115 V and 5 A at 230 V for the starting-current consideration; cable cross-section also limits the allowed protection. Do not treat those values as output-current ratings.
  • Can maintenance personnel simply exchange the internal PS931 fuse?
    The internal fuse is not designated as user-changeable. An internal short-circuit failure needs an appropriate service assessment; fitting a new fuse or bypassing it is not the prescribed user maintenance procedure.
  • Does the 20 ms buffering value make this an uninterrupted DC source?
    No. The stated line-dip buffering is 20 ms at 187 V input and 2 A output, with a 1 s repetition interval. It is a specified short-dip condition, not a promise of continuous output during an extended mains outage.
  • Can a vertical S5 arrangement use the horizontal ambient rating?
    The permitted ambient range is 0-60 C for the horizontal PLC arrangement but 0-40 C for the vertical arrangement. Preserve the installation-specific limit rather than applying the higher horizontal value to a vertical cabinet layout.
  • Which PS931 terminals belong to the CPU's 24 V supply rather than the AC line?
    L+ and M carry the DC output and connect to the corresponding CPU supply terminals. L1, N and protective earth belong to the incoming AC connection. Keep the two terminal groups distinct when restoring wiring.
  • Is a dark front panel enough to rule out a supply fault?
    No dedicated fault LED is fitted. Verify the selected AC input and the DC output through the appropriate qualified electrical checks; absence of a fault light is not an output-voltage indication.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.