Technical specifications for 6ES5928-3UA11

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6ES5928-3UA11
  • Estimated shipping dimensions:
    4.1x20.4x25.5cm
  • Weight:
    0.9 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Controller family:
    SIMATIC S5
  • CPU:
    CPU 928
  • Target controller:
    S5-135U programmable controller
  • Product status:
    Discontinued product

Information

Overview Manuals Common Applications Product Precautions
Siemens 6ES5928-3UA11 is a SIMATIC S5 CPU 928 for the S5-135U programmable controller. It is a discontinued legacy CPU and requires the exact program, rack and interface configuration.
  • CPU 928 processing
  • S5-135U rack use
  • Legacy program execution
  • Controlled spare replacement

Use only the complete Siemens 6ES5928-3UA11 identity and the current manufacturer documentation. Confirm installed hardware, wiring, firmware or parameter compatibility and the approved maintenance record before replacement or release.

Important Notice: Verify 6ES5928-3UA11 from the physical marking and current manufacturer documentation before installation or configuration.

Siemens 6ES5928-3UA11 Manuals & Downloads
Siemens 6ES5928-3UA11 Technical Reference (PDF)Siemens 6ES5928-3UA11 Installation & Commissioning Guide (PDF)

The first document is the model-specific technical reference. The second is a distinct installation and commissioning guide with checks and acceptance records.

Machine control
Executes an approved S5-135U program.
Process control
Runs configured sequence and interlock logic.
Legacy maintenance
Preserves the installed CPU 928 platform.
Spare replacement
Restores only an exact approved CPU configuration.
Read the applicable Siemens instructions before work. Verify 6ES5928-3UA11 and the installed system configuration.
1
Verify the complete Siemens 6ES5928-3UA11 marking before work.
2
Review the current Siemens source documentation and the installed-system record.
3
Record the slot, connector, terminal and companion-hardware arrangement before removal.
4
Place the controller, drive or machine in the approved maintenance state before handling.
5
Use ESD controls and protect keyed connectors, terminals and circuit-board components.
6
Confirm the documented electrical and interface values for 6ES5928-3UA11 before energization.
7
Restore wiring, shielding, grounding and mechanical retention exactly as documented.
8
Run model-specific diagnostics and a controlled functional test before production release.

Technical notes

Use only the complete Siemens 6ES5928-3UA11 identity and the current manufacturer documentation. Confirm installed hardware, wiring, firmware or parameter compatibility and the approved maintenance record before replacement or release.

FAQ View All FAQ

  • Which controller uses the 6ES5928-3UA11 CPU?
    This order number is the SIMATIC S5 CPU 928 used with the S5-135U programmable controller.
  • Why is the existing S5 program backup essential?
    The CPU is a discontinued legacy product, so the approved program, parameter and memory record must be preserved before replacement.
  • What rack information should be captured for a CPU 928 exchange?
    Record the S5-135U rack position, adjacent modules, interface connections, memory arrangement and current diagnostic state.
  • Can an S5 CPU with a similar name be substituted directly?
    No. CPU type, memory, interfaces, program compatibility and rack configuration require documented engineering approval.
  • What should be compared before loading the saved program?
    Confirm the full 6ES5928-3UA11 identity, installed memory and interface arrangement, then use the controlled project copy.
  • How should the first restart be controlled?
    Restore the approved configuration, monitor diagnostics and outputs, and keep the process in the authorized commissioning state.
  • Which functions should be checked after the CPU 928 starts?
    Verify program execution, communication, configured I/O response, interlocks and the intended machine or process sequence.
  • What belongs in the final CPU replacement record?
    Document the CPU identity, program revision, rack configuration, diagnostics and the accepted controlled functional test.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.