6SL3352-1AE37-5BA1

SINAMICS 745 A Replacement Power Block for V and W Phases
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

Siemens 6SL3352-1AE37-5BA1 is a SINAMICS 745 A replacement power block for the V and W phases of a 380-480 V AC Drive/Power Module. It restores the two inverter phase sections within the matching drive power assembly.

Ask our team:

Get a quick price for: 6SL3352-1AE37-5BA1
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 6SL3352-1AE37-5BA1

Technical specifications for 6SL3352-1AE37-5BA1

  • Manufacturer:
    Siemens
  • Product Category:
    Server Driver
  • Spare Part Number:
    6SL3352-1AE37-5BA1
  • Estimated shipping dimensions:
    37.4x27x9.5cm
  • Weight:
    3.1 kg
  • Tariff Code:
    85049090
  • Counliy of origin:
    Germany
  • Product type:
    Replacement power block
  • Supply system:
    3 AC
  • Voltage range:
    380-480 V
  • Line frequency:
    50/60 Hz
  • Rated current:
    745 A
  • Power section:
    V and W phases
  • Module finish:
    Painted
  • Busbar finish:
    Nickel-plated
  • Export classification:
    AL:N / ECCN:EAR99H
  • Quantity unit:
    1 piece

Information

Information

Overview Manuals Common Applications Product Precautions
Siemens 6SL3352-1AE37-5BA1 is a SINAMICS 745 A replacement power block for the V and W phases of a 380-480 V AC Drive/Power Module. It restores the two inverter phase sections within the matching drive power assembly.
  • Provides the V- and W-phase semiconductor power section of the specified AC Drive/Power Module
  • Carries the documented 745 A power path for the 380-480 V three-phase drive execution
  • Uses painted power assemblies for the identified replacement configuration
  • Uses nickel-plated busbars at the documented high-current interconnections

6SL3352-1AE37-5BA1 is installed with matching SINAMICS AC Drive/Power Module chassis, documented V- and W-phase busbar positions, approved gate-drive and control connections, installed cooling and protective-conductor arrangement in the approved SINAMICS AC Drive/Power Module arrangement.

Isolate and discharge the complete drive DC link before removing the 6SL3352-1AE37-5BA1 power block. Match the V/W phase position, busbar interfaces, control connectors and cooling path before controlled energization.

Important Notice: Verify the complete 6SL3352-1AE37-5BA1 marking and the V/W phase assignment before dismantling the drive. Preserve the documented connections and complete the controlled commissioning checks before service.

6SL3352-1AE37-5BA1 Engineering Documents
Apter Power 6SL3352-1AE37-5BA1 V/W Power-Stage Engineering PDFApter Power 6SL3352-1AE37-5BA1 Phase-Block Changeout Workbook PDF
The first document consolidates the exact article record and engineering data. The second provides a separate installation, safety or commissioning reference for the identified hardware function.
V/W phase-section restorationRestores the two named inverter phases without transferring identity from another power-block execution.
Large motor-drive power maintenanceReturns a documented 745 A drive power path to service after controlled isolation and inspection.
High-current drive cabinet refurbishmentSupports cabinet maintenance where the painted assembly and nickel-plated busbar execution must be preserved.
Controlled power-module recommissioningProvides a defined sequence for insulation, connection and phase-output verification before motor operation.
Before work, verify 6SL3352-1AE37-5BA1 against the installed SINAMICS AC Drive/Power Module power hardware and follow the applicable Siemens isolation and commissioning procedure.
1Verify the complete 6SL3352-1AE37-5BA1 marking and the V/W phase assignment before dismantling the drive.
2Isolate incoming three-phase power and prove the DC link discharged with the approved procedure.
3Record every busbar, gate-drive, sensor, cooling and protective-conductor connection before removal.
4Protect semiconductor assemblies from ESD and avoid mechanical loading of the control connectors.
5Inspect nickel-plated busbar contact faces and retain the manufacturer-specified hardware arrangement.
6Confirm the painted module execution and the 745 A, 380-480 V drive identity before installation.
7Energize through the approved commissioning sequence and observe drive diagnostics before enabling the motor.
8Verify V/W phase output behavior under controlled conditions before returning the machine to automatic service.

Alternative Names

Alternative Names

6SL33521AE375BA1

Technical notes

Technical notes

Isolate and discharge the complete drive DC link before removing the 6SL3352-1AE37-5BA1 power block. Match the V/W phase position, busbar interfaces, control connectors and cooling path before controlled energization.

FAQS

  • Which phase positions does 6SL3352-1AE37-5BA1 replace?
    It is the Siemens replacement power block for the V and W phases of the specified AC Drive/Power Module.
  • Which drive electrical execution must match 6SL3352-1AE37-5BA1?
    Match the installed 380-480 V three-phase, 50/60 Hz, 745 A AC Drive/Power Module execution.
  • What must be discharged before removing 6SL3352-1AE37-5BA1?
    Isolate the incoming supply and complete the approved DC-link discharge and absence-of-voltage verification before opening the power section.
  • Which connections should be documented before exchanging 6SL3352-1AE37-5BA1?
    Record V/W busbars, gate-drive plugs, sensor leads, cooling interfaces and protective bonding before disassembly.
  • How should the busbar interfaces of 6SL3352-1AE37-5BA1 be inspected?
    Check the nickel-plated contact surfaces, insulators and fastening hardware for contamination, damage and correct position.
  • Can 6SL3352-1AE37-5BA1 be installed in a different current-class drive?
    The complete 745 A, 380-480 V execution and the V/W phase function must match the installed power module.
  • Which start-up checks are required after fitting 6SL3352-1AE37-5BA1?
    Use the approved drive start-up sequence, review diagnostics and verify the V/W phase behavior under controlled conditions.
  • What service record should be retained for 6SL3352-1AE37-5BA1?
    Retain the exact identity, as-found connections, installed phase position, fastening inspection and final functional-test result.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.