Speak to a sourcing specialist
sales13@apterpower.com

IOP301

Isolated Analog Input Module
Ships by Thursday, November 19
Metso IOP301 (1)
Metso IOP301 (2)
Metso IOP301 (3)
Metso IOP301 (1)
Metso IOP301 (2)
Metso IOP301 (3)
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Metso IOP301 is a 16-channel isolated analog-input module for the maxPAC Model IOP system. Each channel can be configured for current or voltage input, with field or system loop supply as applicable.
  • Manufacturer part number
    IOP301
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    4.3cm × 31.5cm × 25.6cm
  • Country of Origin
    Finland
Get a quick price for IOP301
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete IOP301 marking, installed maxPAC Model IOP / DPU4 configuration and relevant photos with your enquiry.
  • 1

    Confirm the offer

    Check that the quotation names IOP301 and states the supplied module or terminal, revision and separately required accessories.
  • 2

    Arrange dispatch

    Confirm delivery details and receive tracking information when the shipment is arranged.
  • Match the complete marking

    Include IOP301 and its visible revision or assembly identity in your enquiry. Keep the complete reference on the quotation.
  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered IOP301 with the installed equipment and applicable Metso documents.

Technical specifications for IOP301

  • Manufacturer:
    Metso Auttomation
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IOP301
  • Weight:
    0.6 kg
  • Tariff Code:
    8537101190
  • Product role:
    Isolated analog-input module
  • Input channels:
    16, with DPU4E mode
  • DPU4A/B mode:
    15 channels, 16 addresses
  • DPU4E mode:
    16 channels, two addresses
  • Input forms:
    4–20 mA or 0–2.4 V
  • Current-loop supply:
    Field or 24 V backplane supply
  • Resolution:
    15 bits plus sign
  • Scan rate:
    100 ms
  • Accuracy:
    ±0.1% of reading at 25 °C
  • Conversion:
    Sigma-delta oversampling
  • Field-to-logic isolation:
    1500 V AC
  • Channel-to-channel isolation:
    500 V AC
  • Active indicator:
    Steady on in normal scan; diagnostic blink codes
  • Self-calibration:
    At power-up and periodically online

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Metso IOP301. This maxPAC analog-input module receives isolated transmitter measurements and presents converted values to the configured DPU.
Product role: Isolated analog-input module
Input channels: 16, with DPU4E mode
DPU4A/B mode: 15 channels, 16 addresses
DPU4E mode: 16 channels, two addresses
IOP301 has 16 isolated input circuits and supports any mix of current and voltage inputs. A 4–20 mA loop may use field supply or 24 V system loop power from the backplane; voltage channels use the 0–2.4 V input span. Each channel has input-type jumpers, so its wiring and scaling must match the transmitter and saved DPU configuration.

The module has two operating modes. With DPU4E it uses two bus addresses and provides all 16 channels; with DPU4A/B it requires 16 addresses and provides 15 channels. It uses sigma-delta conversion, 15-bit-plus-sign resolution, a 100 ms scan rate and self-calibration at start-up and online. The manual gives ±0.1% of reading accuracy at 25 °C, with 1500 V AC field-to-logic and 500 V AC channel-to-channel isolation.

The Active LED reports communication and diagnostic status: steady operation indicates normal communication, while grouped blink codes identify faults such as A/D communication or self-calibration failure. For redundant modules sharing a transmitter, Metso specifies voltage-input configuration with external 100-ohm shunts and separately fused 24 V connections. Use the documented wiring and IOP306 components for that arrangement.
Installed-system reference: maxPAC Model IOP / DPU4. Check DPU mode and per-channel jumper settings.
Technical downloads for Metso IOP301: original manufacturer excerpt and an Apter Power installation and commissioning guide.
The technical excerpt reproduces selected Metso source pages. The installation guide is prepared by Apter Power; verify the complete IOP301 marking and apply the full manufacturer and site procedures.
Installation and commissioning checks for Metso IOP301.
Check DPU mode

Set W6 for DPU4E or DPU4A/B and confirm the corresponding address use.

Check mains filter

Set W1 for the applicable 50 or 60 Hz environment.

Set channel jumpers

Apply A–E input-type jumper positions for each selected signal form.

Protect loop supply

Check the system or field supply and independently fuse redundant transmitter feeds.

Inspect shunts

Use the documented external 100-ohm shunts for redundant common-transmitter wiring.

Review diagnostics

After power-up, confirm Active indication and resolve any coded A/D or calibration fault.

Alternative Names

Metso IOP301

Technical notes

Operating mode: DPU4E uses two addresses and 16 channels; DPU4A/B uses 16 addresses and 15 channels.

Signal setup: Configure each channel’s A–E jumpers for its current or voltage input and supply path.

Technical reference: Metso Automation MAX Controls maxPAC Hardware Reference Guide, 277596.

FAQ View All FAQ

  • How many analog inputs does Metso IOP301 provide with DPU4E?
    The DPU4E mode provides 16 channels while using two bus addresses.
  • How does Metso IOP301 operate with DPU4A/B?
    In DPU4A/B mode it uses 16 addresses and provides 15 channels.
  • Which signal forms can Metso IOP301 accept?
    Channels may be configured for 4–20 mA current or 0–2.4 V voltage input.
  • Can Metso IOP301 power a current loop from the system?
    Yes. The module can use a 24 V loop supply provided through the backplane for the documented wiring arrangement.
  • What resolution and scan rate are specified for Metso IOP301?
    The guide specifies 15 bits plus sign and a 100 ms scan rate.
  • How is Metso IOP301 isolated?
    The guide lists 1500 V AC field-to-logic isolation and 500 V AC between channels.
  • What does a blinking Active LED indicate on Metso IOP301?
    Blink patterns encode detected faults, including A/D communication and self-calibration errors; compare the pattern with the guide.
  • How are redundant Metso IOP301 inputs wired to one transmitter?
    Configure the inputs for voltage with external 100-ohm shunts and separately fuse the 24 V feed as specified for the shared-transmitter circuit.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.