METRIX 10026-02-12-05-02
METRIX 10026-02-12-05-02
METRIX 10026-02-12-05-02
METRIX 10026-02-12-05-02
METRIX 10026-02-12-05-02
METRIX 10026-02-12-05-02
Product image is representative; revision or series may vary. Contact us to request a specific version.

10026-02-12-05-02

High-Pressure Reverse-Mount Proximity Probe
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

METRIX 10026-02-12-05-02 is a high-pressure reverse-mount proximity probe from the 10026 product family. It provides an 8 mm eddy-current sensing interface for installations using the matching high-pressure probe mount and transducer system.

Ask our team:

Get a quick price for: 10026-02-12-05-02
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 10026-02-12-05-02

Technical specifications for 10026-02-12-05-02

  • Manufacturer:
    METRIX
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    10026-02-12-05-02
  • Estimated shipping dimensions:
    55.5x1.5x1.5cm
  • Weight:
    0.04 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product family:
    10026
  • Probe style:
    Reverse mount
  • Tip diameter:
    8 mm
  • Probe thread:
    3/8-24 UNF
  • Pressure rating:
    1000 psig (6.89 MPa)
  • Tip material:
    Ryton
  • Case material:
    300-series stainless steel
  • Cable impedance:
    95 ohm
  • Connector:
    Gold-plated brass
  • Minimum bend radius:
    25 mm
  • Probe and cable temperature:
    -40 to +177 deg C
  • Target material:
    4140 steel
  • Relative humidity:
    100 percent condensing; not submersible

Information

Information

Overview Manuals Common Applications Product Precautions
10026-02-12-05-02 provides a sealed reverse-mount 8 mm proximity sensing point for a documented high-pressure installation.
  • Uses a reverse-mount construction for the sealed probe assembly
  • Supports the documented high-pressure mounting arrangement
  • Carries the eddy-current probe signal through abrasion-resistant cable
  • Provides exact article identity for controlled probe replacement

The probe is fitted into the approved high-pressure sleeve and housing arrangement, with cable routing and connector protection maintained outside the pressure boundary. Commissioning checks mount identity, insertion depth, pressure seal, static gap and transducer response.

Important Notice: Confirm 10026-02-12-05-02, reverse-mount probe, 8 mm tip, 3/8-24 UNF mount, 5499 housing and sleeve, pressure rating, seal condition, cable route, connector, matching transducer electronics, static gap and controlled pressure and response tests before commissioning.

Apter Power 10026-02-12-05-02 Manuals and Guides

The first document is the model-specific technical and system reference. The second is a distinct field workbook for installation, wiring, commissioning and acceptance records.

High-pressure compressor monitoring
Measures shaft motion where the probe mount must retain a pressure boundary.
Sealed bearing-housing installations
Supports proximity measurement through the matching high-pressure sleeve.
Shaft-vibration measurement
Provides the sensing element of a documented eddy-current loop.
High-pressure probe replacement
Restores the exact probe and mount relationship without disturbing system calibration.
Read the applicable METRIX installation instructions before work. Verify 10026-02-12-05-02, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the full 10026-02-12-05-02 marking and reverse-mount execution.
2
Depressurize the probe location and place the machine in maintenance state.
3
Isolate the monitoring loop and protect the probe connector from contamination.
4
Inspect the 5499 housing, probe sleeve, O-ring and pressure-seal surfaces.
5
Maintain the documented cable bend radius and connector-tightening method.
6
Verify insertion depth and keep the probe tip clear of the target during adjustment.
7
Match the probe to the approved extension and signal conditioner arrangement.
8
Restore pressure integrity, set gap and prove polarity and response before release.

Technical notes

Technical notes

Install 10026-02-12-05-02 only in the documented reverse-mount high-pressure arrangement with the matching 5499 mounting hardware. Protect the pressure seal, maintain cable bend radius and connector torque, then set gap and verify the complete proximity loop under controlled conditions.

FAQS

  • Which complete article marking distinguishes 10026-02-12-05-02 from nearby variants?
    Confirm 10026-02-12-05-02, reverse-mount probe, 8 mm tip, 3/8-24 UNF mount, 5499 housing and sleeve, pressure rating, seal condition, cable route, connector, matching transducer electronics, static gap and controlled pressure and response tests before commissioning.
  • What system function is assigned specifically to 10026-02-12-05-02?
    Uses a reverse-mount construction for the sealed probe assembly. It provides an 8 mm eddy-current sensing interface for installations using the matching high-pressure probe mount and transducer system.
  • How should the host position and mating hardware for 10026-02-12-05-02 be verified?
    The probe is fitted into the approved high-pressure sleeve and housing arrangement, with cable routing and connector protection maintained outside the pressure boundary. Commissioning checks mount identity, insertion depth, pressure seal, static gap and transducer response.
  • Which power, signal or field circuits must be controlled before servicing 10026-02-12-05-02?
    Depressurize the probe location and place the machine in maintenance state. Isolate the monitoring loop and protect the probe connector from contamination.
  • What wiring or connector checks are required for 10026-02-12-05-02?
    Verify insertion depth and keep the probe tip clear of the target during adjustment.
  • How is the approved software or hardware setup for 10026-02-12-05-02 preserved?
    Match the probe to the approved extension and signal conditioner arrangement.
  • Which alarms or status indications should be reviewed after replacing 10026-02-12-05-02?
    Confirm the full 10026-02-12-05-02 marking and reverse-mount execution. Maintain the documented cable bend radius and connector-tightening method.
  • How is a controlled functional release completed for 10026-02-12-05-02?
    Restore pressure integrity, set gap and prove polarity and response before release.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.