Match the complete marking
Include 3601E and its visible revision or assembly identity in your enquiry. Keep the complete reference on the quotation. -
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 3601E with the installed equipment and applicable Triconex documents.
Technical specifications for 3601E
-
Manufacturer:Invensys
-
Product Category:DCS Systems
-
Spare Part Number:3601E
-
Weight:2.84 kg
-
Tariff Code:8537101190
-
Product role:TMR 115 V AC digital-output module
-
Output points:16, non-commoned
-
Nominal field voltage:115 V AC
-
Operating field range:80–155 V AC
-
Frequency range:47–63 Hz
-
Maximum point current:2 A per output
-
Surge rating:12 A per cycle
-
Maximum load leakage:2 mA at 60 Hz
-
Maximum chassis leakage:4 mA at 60 Hz
-
Field fuse:3 A fast-acting per output, on termination
-
Point isolation:1500 V DC for 3601E
-
Module indicators:PASS, FAULT, ACTIVE
-
Field alarm:LOAD/FUSE
-
Termination:Separate external termination panel
Information
- Triconex 3601E. This Tricon output module votes three processor-channel commands into field switching for 16 separate 115 V AC loads.
Output points: 16, non-commoned
Nominal field voltage: 115 V AC
Operating field range: 80–155 V AC
For 3601E, the product guide specifies 115 V AC nominal, an 80–155 V AC operating range and 47–63 Hz. Each point is rated at a maximum 2 A, with 12 A surge per cycle. A 3 A fast-acting fuse belongs at each field termination. The 3601E point-isolation figure is 1500 V DC; the higher 2500 V DC figure in the shared table is explicitly marked for 3601T.
A voltage-loopback circuit checks output-switch behavior against the command, and the LOAD/FUSE indication reports a field-voltage mismatch. PASS, FAULT and ACTIVE show module status; an indicated channel fault calls for diagnosis and does not alone prove complete module failure. Assess the 2 mA maximum load leakage and 4 mA chassis leakage at 60 Hz when selecting sensitive field devices.
-
Triconex 3601E technical reference
Original manufacturer excerpt - PDF, 1 pages. Exact-model technical data and source boundaries. -
Triconex 3601E installation guide
Prepared by Apter Power - PDF, 5 pages. Identity, installed-system checks, commissioning and handover.
Compatibility boundary: Match the exact 3601E execution, field fuse, terminal panel and load characteristics; the 3601T isolation note is separate.
-
Discrete AC actuation
Switch an approved 115 V AC field device on one of the 16 separately wired points. -
Fault-tolerant control
Use the voted TMR output path in a configured Tricon safety or process-control application. -
Hot-spare service
Apply the documented hot-spare arrangement with the correct configured slot and termination cable. -
Field diagnostics
Use point state and LOAD/FUSE indications to locate a load, fuse or field-voltage discrepancy.
Treat each 115 V AC output point as a separately powered circuit before handling the panel.
Confirm 3601E and its configured chassis key; do not use 3601T isolation limits.
Verify the external termination panel and backplane cable before commissioning.
Confirm one 3 A fast-acting fuse for each output on the field termination.
Keep steady and surge demand within 2 A per point and 12 A per cycle.
Test commanded ON/OFF state, point indication and LOAD/FUSE alarms at the field device.
Alternative Names
Technical notes
Output relationship: 3601E votes TMR commands for 16 non-commoned 115 V AC field points through an external termination panel.
Variant boundary: Use the 3601E 1500 V DC isolation value; the 2500 V DC footnote applies only to 3601T.
Technical reference: Triconex Technical Product Guide for Tricon Systems, 9791007-013.
FAQ View All FAQ
-
How many output points does Triconex 3601E provide?It has 16 non-commoned TMR digital-output points.
-
What field-voltage range applies to Triconex 3601E?The guide specifies 115 V AC nominal and an 80–155 V AC operating range at 47–63 Hz.
-
What current can each Triconex 3601E output carry?The maximum is 2 A per point, with a 12 A surge per cycle.
-
Where are the output fuses for Triconex 3601E?The field termination uses one 3 A fast-acting fuse per output.
-
What external termination does Triconex 3601E require?A separate external termination panel connects to the Tricon backplane through its cable interface.
-
What does the LOAD/FUSE indication mean on Triconex 3601E?It signals a mismatch between detected field voltage and the commanded output state.
-
What point-isolation value belongs to Triconex 3601E?The shared model table gives 1500 V DC for 3601E; the 2500 V DC footnote applies to 3601T.
-
How should a Triconex 3601E channel fault be interpreted?A FAULT indication calls for channel diagnosis; the guide distinguishes a channel fault from proof of a complete module failure.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.