Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for EMPII 3006
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for EMPII 3006

  • Manufacturer:
    Invensys
  • Product Category:
    DCS Systems
  • Spare Part Number:
    3006
  • Estimated shipping dimensions:
    49x45.3x6.8cm
  • Weight:
    2.6 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product number:
    3006
  • Processor generation:
    Enhanced Main Processor II
  • Tricon version:
    9
  • Memory:
    2 MB
  • Controller architecture:
    Three main processors per Tricon system

Information

Overview Manuals Common Applications Product Precautions
Triconex EMPII 3006 is an Enhanced Main Processor II module for Tricon version 9 systems. It operates as one of three processors executing and coordinating the safety-control application.
  • Executes one channel of the triplicated Tricon version 9 control program
  • Participates in input-table voting and output-data coordination across the controller
  • Communicates with the assigned I/O subsystem and controller communication buses
  • Reports processor and system health through Tricon diagnostics

EMPII 3006 installs with Tricon version 9 main chassis, two matching 3006 processor modules, approved Tricon application, triplicated I/O and communication buses in an engineered Tricon version 9 controller configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this enhanced main processor ii module.

Important Notice: Confirm the complete EMPII 3006 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power EMPII 3006 Manuals and Guides
Apter Power EMPII 3006 Product Technical Reference PDFApter Power EMPII 3006 Installation and Verification PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Legacy Tricon version 9 safety controlSupports legacy Tricon version 9 safety control through the installed enhanced main processor ii module in a configured Tricon system.
Triplicated main-processor replacementUses EMPII 3006 for triplicated main-processor replacement after the assigned host module, field interface and channel mapping are confirmed.
Emergency shutdown application retentionApplies the EMPII 3006 hardware arrangement to emergency shutdown application retention with controlled wiring and signal verification.
Installed-base controller lifecycle maintenanceProvides a defined engineering path for installed-base controller lifecycle maintenance, including installation checks and final functional proof.
Read the applicable Triconex installation instructions before work. Verify EMPII 3006 and the installed Tricon version 9 controller configuration.
1Verify EMPII 3006 and the installed Tricon version 9 chassis before work.
2Place the safety controller and process in the approved maintenance state.
3Record the three processor identities, positions, revisions, and active diagnostics.
4Back up the approved control application and configuration before module removal.
5Use ESD controls and inspect the keyed main-chassis connector.
6Do not transfer 3008 or other-generation processor specifications to EMPII 3006.
7Confirm all three processors synchronize and communicate with the I/O subsystem.
8Validate control execution, fault reporting, and the intended safety response before service.

Technical notes

Confirm the complete EMPII 3006 identity, matching processor set, installed Tricon version, and approved application backup before exchanging a module; validate synchronization and diagnostics afterward.

FAQ View All FAQ

  • Which installation error is most important to prevent on EMPII 3006?
    Do not interchange EMPII 3006 with an adjacent execution or alter its matched Tricon version 9 main chassis; the exact electrical, channel, and connector arrangement must be retained.
  • How is 2 MB generation identity handled during a EMPII 3006 replacement?
    Record the installed state first, isolate the associated process function, reproduce only the approved model-specific arrangement, and verify it before energization.
  • Which diagnostics should be reviewed after installing EMPII 3006?
    Review the applicable point, module, power, communication, or load indicators for EMPII 3006, then confirm the intended role: executes one channel of the triplicated tricon version 9 control program.
  • Can EMPII 3006 be substituted for a similar Triconex model without a configuration review?
    No. Confirm the exact model, companion hardware, signal execution, system version, and approved configuration before any substitution.
  • What evidence should be retained after legacy application backup and synchronization testing on EMPII 3006?
    Retain the full EMPII 3006 identity, as-left connections or settings, final diagnostics, measured functional-test result, and authorization to return the affected process function to service.
  • Which installed hardware must be matched before fitting EMPII 3006?
    Match EMPII 3006 to Tricon version 9 main chassis and two matching 3006 processor modules, then confirm the complete physical marking and assigned Tricon version 9 controller position.
  • How should an engineer verify Tricon version 9 compatibility for EMPII 3006?
    Use the approved connection drawing and the model-specific values in Triconex Lifecycle Phase Report; preserve the as-found terminal, connector, polarity, shield, and channel identity.
  • What check is required for three matched main processors when commissioning EMPII 3006?
    Apply a controlled signal or command within the documented range and compare the field result, controller indication, and product diagnostics before normal operation.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.