Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for FS-TSFIRE-1624
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for FS-TSFIRE-1624

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    FS-TSFIRE-1624
  • Estimated shipping dimensions:
    17x7x5.8cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input channels:
    16
  • External supply:
    24 VDC, +25% / -15%
  • Maximum supply current:
    570 mA at 24 VDC
  • Typical current with EOL resistors:
    70 mA at 24 VDC
  • Typical no-load current:
    11 mA at 24 VDC
  • Input voltage with 4.7 kOhm EOL:
    20.5 VDC typical
  • No-load input voltage:
    23.5 VDC typical
  • Channel resistance:
    680 Ohm +/-5%
  • Shorted current:
    35 mA at 24 VDC
  • Dimensions:
    170 x 70 x 64 mm

Information

Overview Manuals Common Applications Product Precautions
Honeywell FS-TSFIRE-1624 converts 24 V fire-detector and manual-call-point signals for a Safety Manager SAI-1620m module. DIN-rail mounting and forty-eight screw terminals support cabinet field wiring.
  • 16 monitored detector inputs
  • External 24 VDC supply
  • Global detector reset relay
  • TS32 or TS35 DIN-rail mounting

Commission each detector loop independently so wiring faults, end-of-line supervision, alarm response and the common reset circuit are demonstrated without masking channel-specific conditions.

Important Notice: Match the full FS-TSFIRE-1624 identity, 24 VDC detector supply, channel allocation and SAI-1620m interface before field work.

Honeywell FS-TSFIRE-1624 Manuals & Downloads
Honeywell FS-TSFIRE-1624 Official Technical Reference Excerpt (PDF)Honeywell FS-TSFIRE-1624 Installation & Commissioning Guide (PDF)

The Official Technical Reference Excerpt contains the exact module description, connection data, technical limits and application drawing. The Installation & Commissioning Guide organizes supply isolation, loop checks, detector reset testing and final Safety Manager acceptance.

Fire and gas panels
Terminates monitored 24 V fire-detector loops for Safety Manager processing.
Manual call-point circuits
Accepts digital alarm inputs with end-of-line supervision.
Redundant safety input
Transfers the sixteen signals to a redundant SAI-1620m pair through the system cable.
Detector reset groups
Removes field supply through the common relay to reset connected detectors.
Apply these controls specifically to Honeywell FS-TSFIRE-1624 before isolation, replacement, reconnection and final release.
1
Verify the complete FS-TSFIRE-1624 label and sixteen-channel assignment before field work.
2
Isolate the external 24 VDC supply and prove de-energization at terminals A and B.
3
Preserve the detector polarity, channel numbering and end-of-line resistor location for every loop.
4
Keep total field-wire resistance below the stated 100 Ohm limit.
5
Use the specified conductor size, seven-millimeter strip length and 0.5 Nm terminal torque.
6
Check the global-reset relay wiring separately because that function is not safety related.
7
Test open, normal, alarm and short-circuit conditions without exceeding the detector rating.
8
Verify Safety Manager diagnostics, reset behavior and all sixteen channel states before handover.

Alternative Names

FS TSFIRE 1624, TSFIRE-1624

Technical notes

Record all sixteen detector-loop assignments, polarities and end-of-line locations before isolation. Prove normal, alarm, open-circuit, short-circuit and global-reset behavior against the corresponding SAI-1620m indications.

FAQ View All FAQ

  • How many inputs does Honeywell FS-TSFIRE-1624 provide?
    The field termination assembly provides sixteen fire-detector input channels.
  • Which Safety Manager input module works with Honeywell FS-TSFIRE-1624?
    A SICC-0001/Lx cable transfers the channels to one SAI-1620m module or a redundant pair.
  • What supply range applies to Honeywell FS-TSFIRE-1624?
    The external supply is 24 VDC with +25 percent and -15 percent tolerance.
  • What line-monitoring resistor is used with Honeywell FS-TSFIRE-1624?
    A typical end-of-line value is 4.7 kOhm with +/-5 percent tolerance and 0.25 W rating.
  • What current does Honeywell FS-TSFIRE-1624 draw with end-of-line resistors?
    Typical current is 70 mA at a 24 VDC external supply.
  • How is the global reset performed by Honeywell FS-TSFIRE-1624?
    Energizing the common relay removes detector supply; the relay operates from 17 to 39 VDC.
  • Which DIN rails accept Honeywell FS-TSFIRE-1624?
    The module mounts on TS32 or TS35 x 7.5 DIN EN rails and uses 171 mm of rail length.
  • What loop conditions should be proven after installing Honeywell FS-TSFIRE-1624?
    Check normal supervision, fire alarm, open circuit, short circuit, global reset and the corresponding SAI-1620m indications for every assigned channel.