TC-FTEB01 51309512-125

Fault-Tolerant Ethernet Bridge
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Honeywell TC-FTEB01 51309512-125 is the TC-FTEB01 Fault Tolerant Ethernet Bridge used for bridging a C200 controller or FIM-only chassis to the Fault Tolerant Ethernet supervisory network in a documented Honeywell Experion C200 / Series A installation. Confirm the complete identity and installed system configuration before replacement.

Ask our team:

Get a quick price for: TC-FTEB01 51309512-125
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for TC-FTEB01 51309512-125

Technical specifications for TC-FTEB01 51309512-125

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    51309512-125
  • Estimated shipping dimensions:
    3.4x14x14.5cm
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    Fault Tolerant Ethernet Bridge module
  • Model:
    TC-FTEB01
  • Manufacturer item number:
    51309512-125
  • Execution:
    Uncoated TC version
  • Network:
    Honeywell Fault Tolerant Ethernet
  • Supported chassis role:
    C200 controller or FIM-only chassis
  • Quantity per chassis:
    One FTE Bridge
  • Service requirement:
    Device Index, cable-shield ground jumper, MAC addresses and firmware verification

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell TC-FTEB01 51309512-125 is the TC-FTEB01 Fault Tolerant Ethernet Bridge used for bridging a C200 controller or FIM-only chassis to the Fault Tolerant Ethernet supervisory network in a documented Honeywell Experion C200 / Series A installation.
  • Execution: Uncoated TC version
  • Network: Honeywell Fault Tolerant Ethernet
  • Supported chassis role: C200 controller or FIM-only chassis
  • Quantity per chassis: One FTE Bridge

The component remains matched to its installed host, interface hardware and engineering configuration. Commissioning restores that architecture and verifies the intended function under controlled conditions.

Important Notice: Confirm TC-FTEB01 51309512-125, its exact host, installed position, interfaces, configuration, diagnostics and controlled acceptance evidence before release.

TC-FTEB01 51309512-125 Manuals & Downloads

These documents are different: the first consolidates exact product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

TC-FTEB01 Fault Tolerant Ethernet Bridge
Honeywell TC-FTEB01 51309512-125 is the TC-FTEB01 Fault Tolerant Ethernet Bridge used for bridging a C200 controller or FIM-only chassis to the Fault Tolerant Ethernet supervisory network in a documented Honeywell Experion C200 / Series A installation.
Installed-system maintenance
Preserves the documented slot, termination, wiring and configuration during replacement.
Controlled commissioning
Restores power and signals in the approved sequence and reviews diagnostics.
Acceptance verification
Confirms the intended channel, network or safety function before release.
Read the applicable Honeywell installation instructions before work. Verify TC-FTEB01 51309512-125, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete TC-FTEB01 51309512-125 identity on the hardware and maintenance record.
2
Place the affected process in the approved maintenance state.
3
Record the installed position, connectors, terminals, wiring and configuration before removal.
4
Isolate all documented power and field energy and apply ESD controls where required.
5
Inspect the replacement identity, revision, interfaces and mating hardware before installation.
6
Restore every conductor, cable, power path and configuration value to the approved record.
7
Review host, module, channel or network diagnostics after controlled energization.
8
Perform a controlled functional test before release.

Alternative Names

Alternative Names

51309512-125

Technical notes

Technical notes

Install TC-FTEB01 51309512-125 only in its documented Honeywell Experion C200 / Series A position. Preserve the exact interfaces, wiring and configuration, then verify diagnostics and bridging a C200 controller or FIM-only chassis to the Fault Tolerant Ethernet supervisory network under controlled conditions.

FAQS

  • Which network is provided by TC-FTEB01 51309512-125?
    It connects the chassis to Honeywell Fault Tolerant Ethernet.
  • What is bridged through TC-FTEB01 51309512-125?
    It carries communication between the server side and a C200 controller or FIM-only chassis.
  • How many TC-FTEB01 51309512-125 bridge modules are allowed in one applicable chassis?
    One bridge module is allowed per C200 controller or FIM-only chassis.
  • Is TC-FTEB01 51309512-125 the coated version?
    No. The TC prefix identifies the uncoated execution; TK-FTEB01 is the coated model.
  • Which setup value must be unique for TC-FTEB01 51309512-125?
    The Device Index must be set correctly for the installed node.
  • Why should TC-FTEB01 51309512-125 firmware be recorded before service?
    A replacement must run the approved revision for the configured chassis.
  • Which physical network items require inspection around TC-FTEB01 51309512-125?
    Check both FTE cables, cable-shield ground jumper, MAC-address records and chassis grounding.
  • How is TC-FTEB01 51309512-125 released after replacement?
    Verify IP assignment, both FTE paths, diagnostics, firmware and communication with the configured chassis.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.