Speak to a sourcing specialist
sales13@apterpower.com

MC-TDOR12 51309148-175

Relay Output FTA
In Stock
Ships by Sunday, November 29
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Honeywell MC-TDOR12 51309148-175 is the MC-TDOR12 Relay Digital Output FTA used for field termination of sixteen 120 VAC relay digital outputs in a documented PM/APM/HPM Process Manager I/O installation. Confirm the complete identity and installed system configuration before replacement.
Get a quick price for MC-TDOR12 51309148-175
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for MC-TDOR12 51309148-175

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    51309148-175
  • Estimated shipping dimensions:
    12x5.2x30.7cm
  • Weight:
    0.72 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    Relay Digital Output Field Termination Assembly
  • FTA model:
    MC-TDOR12
  • Manufacturer item number:
    51309148-175
  • Channels:
    16 relay outputs
  • Field service:
    120 VAC relay output
  • Terminal type:
    Compression
  • Coating:
    Conformally coated
  • Compliance execution:
    CE-compliant part

Information

Overview Manuals Common Applications Product Precautions
Honeywell MC-TDOR12 51309148-175 is the MC-TDOR12 Relay Digital Output FTA used for field termination of sixteen 120 VAC relay digital outputs in a documented PM/APM/HPM Process Manager I/O installation.
  • Channels: 16 relay outputs
  • Field service: 120 VAC relay output
  • Terminal type: Compression
  • Coating: Conformally coated

The component remains matched to its installed host, interface hardware and engineering configuration. Commissioning restores that architecture and verifies the intended function under controlled conditions.

Important Notice: Confirm MC-TDOR12 51309148-175, its exact host, installed position, interfaces, configuration, diagnostics and controlled acceptance evidence before release.

MC-TDOR12 51309148-175 Manuals & Downloads

These documents are different: the first consolidates exact product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

MC-TDOR12 Relay Digital Output FTA
Honeywell MC-TDOR12 51309148-175 is the MC-TDOR12 Relay Digital Output FTA used for field termination of sixteen 120 VAC relay digital outputs in a documented PM/APM/HPM Process Manager I/O installation.
Installed-system maintenance
Preserves the documented slot, termination, wiring and configuration during replacement.
Controlled commissioning
Restores power and signals in the approved sequence and reviews diagnostics.
Acceptance verification
Confirms the intended channel, network or safety function before release.
Read the applicable Honeywell installation instructions before work. Verify MC-TDOR12 51309148-175, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete MC-TDOR12 51309148-175 identity on the hardware and maintenance record.
2
Place the affected process in the approved maintenance state.
3
Record the installed position, connectors, terminals, wiring and configuration before removal.
4
Isolate all documented power and field energy and apply ESD controls where required.
5
Inspect the replacement identity, revision, interfaces and mating hardware before installation.
6
Restore every conductor, cable, power path and configuration value to the approved record.
7
Review host, module, channel or network diagnostics after controlled energization.
8
Perform a controlled functional test before release.

Alternative Names

51309148-175

Technical notes

Install MC-TDOR12 51309148-175 only in its documented PM/APM/HPM Process Manager I/O position. Preserve the exact interfaces, wiring and configuration, then verify diagnostics and field termination of sixteen 120 VAC relay digital outputs under controlled conditions.

FAQ View All FAQ

  • What load interface does MC-TDOR12 51309148-175 provide?
    It provides relay-output field termination for 120 VAC service.
  • How many relay channels terminate on MC-TDOR12 51309148-175?
    Sixteen relay-output channels terminate on the assembly.
  • Are the field connections on MC-TDOR12 51309148-175 screw or compression type?
    They are compression terminals.
  • Which coating version is MC-TDOR12 51309148-175?
    It is conformally coated.
  • Is MC-TDOR12 51309148-175 the CE-compliant item?
    Yes. The -175 item is the CE execution for this model.
  • Why must field power be isolated before working on MC-TDOR12 51309148-175?
    Its terminals can carry the documented 120 VAC output circuits.
  • What should be recorded before moving wiring from MC-TDOR12 51309148-175?
    Record channel numbers, commons, load supplies and each output's normal state.
  • Which test completes MC-TDOR12 51309148-175 commissioning?
    Exercise every assigned relay output under controlled load conditions and review channel diagnostics.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.