Product Describe:

General Electric DS200SHVMG1ACC is identified as a scr high voltage m-frame interface board for the GE DC2000 M-frame drive-control system. Match the complete marking, board group and installed interface arrangement before replacement.
  • Manufacturer part number
    DS200SHVMG1ACC
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    23.8cm × 17.7cm × 3.8cm
  • Country of Origin
    USA
Get a quick price for DS200SHVMG1ACC
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete DS200SHVMG1ACC marking, required quantity and installed drive context.

  • 1

    Confirm the offer

    Review the offered identity, condition, included items and delivery details.

  • 2

    Arrange dispatch

    Confirm the accepted quantity and destination in the quotation.

  • Match the complete marking

    Compare DS200SHVMG1ACC with the installed board and applicable GE documentation.

  • Check the offered item before ordering

    Request photos of DS200SHVMG1ACC; compare board marking, plugs, jumpers and included items with the installed unit.

Technical specifications for DS200SHVMG1ACC

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    DS200SHVMG1ACC
  • Weight:
    0.34 kg
  • Tariff Code:
    8537101190
  • Board group:
    G1
  • Input shunt-signal span:
    -500 mV to +500 mV
  • Differential-frequency output span:
    0–500 kHz
  • Selectable CT attenuation:
    10:1
  • CT attenuation threshold:
    Insert above 144 mA secondary current
  • CT bypass threshold:
    Bypass at or below 144 mA
  • CT jumper bank:
    JP1–JP8; 8 positions
  • Voltage attenuation bank:
    JP9–JP17; 9 positions
  • Total hardware jumper positions:
    17
  • Low ac-voltage range:
    240–600 V ac
  • High ac-voltage range:
    601–1000 V ac
  • Measured voltage paths:
    3: ac line, motor armature and SCR bridge
  • Revision string:
    ACC

Information

Overview Downloads Applications / Compatibility Product Precautions
  • DS200SHVMG1ACC has a defined scr high voltage m-frame interface board role in the GE DC2000 M-frame drive-control system; selection depends on the complete board marking and installed execution.
Signal conversion: -500 mV to +500 mV shunt input becomes 0–500 kHz differential frequency.
CT boundary: Use 10:1 attenuation only when secondary current exceeds 144 mA.
Voltage boundary: JP9–JP17 distinguish 240–600 V ac from 601–1000 V ac.
The complete DS200SHVMG1ACC marking identifies the offered scr high voltage m-frame interface board. Record the removed board, host position and connected hardware so the comparison uses the actual installed boundary rather than a shortened family name.

Within the GE DC2000 M-frame drive-control system, evaluate this board together with its plugs, jumpers, connected power and feedback paths. Preserve the as-found interface map and revision evidence; a mechanically similar board is not automatically equivalent.

Commissioning should progress from identity and connection checks to controlled power-up, diagnostics and functional proof. Keep measured results, final status and open exceptions in the handover record.
Controller platform reference: GE DC2000 M-frame drive-control system. Use the applicable GE instruction and approved drive drawings for installation and commissioning.
The first document provides the applicable GE technical reference for DS200SHVMG1ACC. The separate Apter Power field guide covers installation checks, commissioning, diagnostics and handover.
Use the applicable General Electric documentation and site-approved installation procedure for DS200SHVMG1ACC.
Prepare General Electric DS200SHVMG1ACC using the applicable installation instructions and site isolation procedure.
Verify the complete identity

Check every token in DS200SHVMG1ACC against the offered board and approved record.

Isolate all connected energy

Follow the site procedure for dc bus, field supply, control power, stored energy and electrostatic handling.

Record plugs and jumpers

Photograph and label every connector, wire jumper and hardware jumper before removal.

Preserve drive configuration

Archive the applicable GE DC2000 M-frame drive-control system settings and drawings before replacement.

Inspect mating hardware

Check connectors, ribbon cables, terminal boards and cable condition before attributing a fault to the board.

Prove the intended function

Use an approved controlled test and retain measured values, diagnostics and acceptance evidence.

Alternative Names

GE DS200 SHVM G1 ACC General Electric SCR High Voltage M Frame Board ACC

Technical notes

Pre-purchase checks: Match the offered DS200SHVMG1ACC nameplate, board group, revision string, connector execution and jumper arrangement with the installed board and approved drawings.

Installed-system compatibility: Verify the exact GE DC2000 M-frame drive-control system position, mating boards, power or signal paths and configuration settings. A family reference or similar appearance does not establish interchangeability.

Quotation confirmation: Confirm available quantity, estimated dispatch date, lead-time starting event, included items and documents in writing.

FAQ View All FAQ

  • How should DS200SHVMG1ACC be identified before a replacement is approved?
    Use the complete DS200SHVMG1ACC marking, board group and revision string. Compare the installed position and documented scr high voltage m-frame interface board role before approval.
  • What evidence should be retained before removing DS200SHVMG1ACC?
    Photograph the complete marking, connector positions, jumper settings and status indications. Record the position in the GE DC2000 M-frame drive-control system.
  • How should the connectors for DS200SHVMG1ACC be checked during installation?
    Label each plug before removal, then restore every connection from the as-found record and the applicable GE manual. Never force a keyed connector.
  • What configuration boundary matters when commissioning DS200SHVMG1ACC?
    Use the exact board group, hardware execution and approved drive record. A similar board family or physical fit does not establish interchangeability.
  • How can a suspected DS200SHVMG1ACC fault be separated from wiring or carrier faults?
    Verify the documented supplies and reference signals first, inspect mating connectors and external wiring, then use a controlled substitution only after both signal paths are recorded.
  • What should be verified after fitting DS200SHVMG1ACC?
    Check normal host indications and the intended scr high voltage m-frame interface board function under an approved controlled test. Retain measured values and diagnostics with the handover record.
  • Can DS200SHVMG1ACC be replaced by a similar-looking assembly?
    No direct equivalence is established by appearance. Compare the complete code, group, revision, connector execution and installed configuration.
  • What handover record is appropriate after work on DS200SHVMG1ACC?
    Retain offered and removed markings, connection photographs, jumper or configuration evidence, measured checks, functional-test results and unresolved exceptions.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.