Technical specifications for DS200FCRRG1AKD
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:DS200FCRRG1AKD
-
Estimated shipping dimensions:29.3x27x3.3cm
-
Weight:0.84 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Board family:DS200
-
Board designation:FCRR
-
Functional group:Firing-circuit regulation
-
Group code:G1
-
Primary revision:A
-
Secondary revision:K
-
Artwork revision:D
Information
- Maintains the FCRR firing-regulator board function
- Retains the G1 board-group execution
- Uses the complete AKD hardware revision identity
- Supports pulse-path and converter-response verification
DS200FCRRG1AKD is installed with compatible GE excitation or drive controller, firing-signal harness, power-converter bridge, approved regulator configuration.
Engineered applications include Generator excitation cabinet service, Converter firing-path restoration, Regulator board replacement, Controlled bridge recommissioning.
Important Notice: Secure the generator or driven equipment, isolate all converter energy and preserve every firing-harness position before replacing DS200FCRRG1AKD; verify pulse inhibit first, then prove regulated bridge response with the approved commissioning procedure.
Apter Power DS200FCRRG1AKD Manuals and Guides
Apter Power DS200FCRRG1AKD System Technical Reference PDFApter Power DS200FCRRG1AKD Field Installation and Acceptance Workbook PDFThe first document consolidates model-specific technical identity and system context. The second provides a separate field workflow for installation, connection checks and commissioning records.
Generator excitation cabinet service
Restores the firing-regulator interface within its documented converter cabinet.
Converter firing-path restoration
Coordinates acceptance checks from controller command through the installed pulse path.
Regulator board replacement
Supports service work where board revision and firing-harness identity must remain unchanged.
Controlled bridge recommissioning
Provides a controlled sequence for checking inhibit, pulse presence and regulated response.
Verify the complete DS200FCRRG1AKD marking and the assigned GE generator excitation and drive-control hardware position before work.
Place the connected machine or process in the approved maintenance state before disturbing DS200FCRRG1AKD.
Isolate the applicable power and field energy, then confirm a safe state before disconnecting DS200FCRRG1AKD.
Record connector, conductor, slot and configuration identities before removal of DS200FCRRG1AKD.
Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies during handling.
Confirm that the installed companion hardware and approved project match the DS200FCRRG1AKD arrangement.
Restore power in a controlled sequence and review device, rack and host diagnostics.
Prove the intended function and retain the final test result before returning DS200FCRRG1AKD to service.
Technical notes
FAQ View All FAQ
-
How should energy be isolated before handling DS200FCRRG1AKD?Use the host-equipment isolation procedure, remove applicable control and field energy, discharge stored energy and prove the required safe state.
-
What compatibility checks apply to DS200FCRRG1AKD?Match DS200FCRRG1AKD to the exact host platform, assigned position, interfaces, hardware revision and approved project record.
-
How should engineers configure DS200FCRRG1AKD after installation?Restore only the approved installed-system settings and assignments; do not transfer parameters from a visually similar catalog number.
-
Which diagnostics should be reviewed when commissioning DS200FCRRG1AKD?Check local indications, host diagnostics, interlocks and the complete commanded or measured signal path before automatic operation.
-
How is the functional path of DS200FCRRG1AKD tested?Apply a controlled test from the originating command or field condition through the connected hardware and record the final response.
-
What maintenance evidence should be retained for DS200FCRRG1AKD?Retain the as-found record, installed position, revision identity, configuration reference, diagnostic state and signed acceptance result.
-
What installed system position is assigned to DS200FCRRG1AKD?Confirm the documented GE generator excitation and drive-control hardware position, complete catalog identity and mating hardware before removing DS200FCRRG1AKD.
-
Which connection records are needed before replacing DS200FCRRG1AKD?Record each connector, conductor, shield, polarity, jumper and position identifier in the as-found state.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.