Speak to a sourcing specialist
sales13@apterpower.com

DS200SBCBG1ADC

GE DS200 brake control card
In Stock
Ships by Thursday, November 12
Fast Shipping Available
General Electric DS200SBCBG1ADC
General Electric DS200SBCBG1ADC
General Electric DS200SBCBG1ADC
General Electric DS200SBCBG1ADC
General Electric DS200SBCBG1ADC
General Electric DS200SBCBG1ADC
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE DS200SBCBG1ADC is a brake control card for a compatible GE drive assembly. It controls the documented braking interface between the drive controller and the installed brake or dynamic-braking hardware.
Get a quick price for DS200SBCBG1ADC
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for DS200SBCBG1ADC

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    DS200SBCBG1ADC
  • Estimated shipping dimensions:
    18.8x14.2x2cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Board family:
    DS200
  • Board designation:
    SBCB
  • Equipment class:
    Brake control card
  • Group code:
    G1
  • Primary revision:
    A
  • Secondary revision:
    D
  • Artwork revision:
    C

Information

Overview Manuals Common Applications Product Precautions
GE DS200SBCBG1ADC is ge ds200 brake control card. It manages the documented braking-control interface between the drive controller and the installed brake or dynamic-braking hardware.
  • Provides the SBCB braking-control function
  • Retains the G1 board-group execution
  • Uses the complete ADC hardware revision
  • Supports brake-command and interlock verification

DS200SBCBG1ADC is installed with compatible GE drive controller, brake contactor or braking assembly, documented command and interlock harness, approved stopping sequence.

Engineered applications include Drive brake-control restoration, Dynamic-braking interface service, Stopping-sequence verification, Controlled drive recommissioning.

Important Notice: Secure the driven equipment, isolate drive and brake energy, record every DS200SBCBG1ADC connection and interlock, then test brake command, release timing and stopping response before automatic operation.

Apter Power DS200SBCBG1ADC Manuals and Guides

Apter Power DS200SBCBG1ADC System Technical Reference PDFApter Power DS200SBCBG1ADC Field Installation and Acceptance Workbook PDF

The first document consolidates model-specific technical identity and system context. The second provides a separate field workflow for installation, connection checks and commissioning records.

Drive brake-control restoration

Restores the board-level brake command path in the documented drive assembly.

Dynamic-braking interface service

Supports verification of brake interlocks before mechanical motion is permitted.

Stopping-sequence verification

Preserves the ADC revision identity during like-for-like service.

Controlled drive recommissioning

Provides a test sequence for command, release, stopping and diagnostic behavior.

Read the applicable GE equipment instructions before work. Verify DS200SBCBG1ADC and the installed GE DS200 drive braking-control hardware configuration.
1

Verify the complete DS200SBCBG1ADC marking and the assigned GE DS200 drive braking-control hardware position before work.

2

Place the connected machine or process in the approved maintenance state before disturbing DS200SBCBG1ADC.

3

Isolate the applicable power and field energy, then confirm a safe state before disconnecting DS200SBCBG1ADC.

4

Record connector, conductor, slot and configuration identities before removal of DS200SBCBG1ADC.

5

Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies during handling.

6

Confirm that the installed companion hardware and approved project match the DS200SBCBG1ADC arrangement.

7

Restore power in a controlled sequence and review device, rack and host diagnostics.

8

Prove the intended function and retain the final test result before returning DS200SBCBG1ADC to service.

Technical notes

Secure the driven equipment, isolate drive and brake energy, record every DS200SBCBG1ADC connection and interlock, then test brake command, release timing and stopping response before automatic operation.

FAQ View All FAQ

  • Which connection records are needed before replacing DS200SBCBG1ADC?
    Record each connector, conductor, shield, polarity, jumper and position identifier in the as-found state.
  • How should energy be isolated before handling DS200SBCBG1ADC?
    Use the host-equipment isolation procedure, remove applicable control and field energy, discharge stored energy and prove the required safe state.
  • What compatibility checks apply to DS200SBCBG1ADC?
    Match DS200SBCBG1ADC to the exact host platform, assigned position, interfaces, hardware revision and approved project record.
  • How should engineers configure DS200SBCBG1ADC after installation?
    Restore only the approved installed-system settings and assignments; do not transfer parameters from a visually similar catalog number.
  • Which diagnostics should be reviewed when commissioning DS200SBCBG1ADC?
    Check local indications, host diagnostics, interlocks and the complete commanded or measured signal path before automatic operation.
  • How is the functional path of DS200SBCBG1ADC tested?
    Apply a controlled test from the originating command or field condition through the connected hardware and record the final response.
  • What maintenance evidence should be retained for DS200SBCBG1ADC?
    Retain the as-found record, installed position, revision identity, configuration reference, diagnostic state and signed acceptance result.
  • What installed system position is assigned to DS200SBCBG1ADC?
    Confirm the documented GE DS200 drive braking-control hardware position, complete catalog identity and mating hardware before removing DS200SBCBG1ADC.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.