Technical specifications for DS200ADGIH1AAA
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:DS200ADGIH1AAA
-
Estimated shipping dimensions:2.5x13x5.5cm
-
Weight:0.06 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Board family:DS200
-
Board designation:ADGI
-
Functional group:Auxiliary drive interface
-
Group code:G1
-
Primary revision:A
-
Secondary revision:A
-
Artwork revision:A
Information
- Uses the complete DS200ADGIH1AAA hardware identity
- Occupies the assigned auxiliary-interface board position
- Preserves the G1 board group and AAA revision execution
- Supports interface-path diagnosis before drive operation
DS200ADGIH1AAA is installed with compatible GE drive controller, assigned DS200 board position, documented interface harness, approved drive configuration record.
Engineered applications include DC drive interface restoration, Auxiliary signal-path verification, Drive cabinet board replacement, Controlled controller recommissioning.
Important Notice: Record every DS200ADGIH1AAA connector, jumper and board position before removal; isolate drive and field energy, retain the G1/AAA execution, and prove the auxiliary interface under controlled conditions before enabling the drive.
Apter Power DS200ADGIH1AAA Manuals and Guides
Apter Power DS200ADGIH1AAA System Technical Reference PDFApter Power DS200ADGIH1AAA Field Installation and Acceptance Workbook PDFThe first document consolidates model-specific technical identity and system context. The second provides a separate field workflow for installation, connection checks and commissioning records.
DC drive interface restoration
Restores the documented auxiliary interface in an installed DC drive cabinet.
Auxiliary signal-path verification
Verifies that each field or communication lead returns to its recorded connector position.
Drive cabinet board replacement
Supports diagnosis of the interface path without transferring settings from another board revision.
Controlled controller recommissioning
Provides a controlled acceptance sequence for board status and connected-device response.
Verify the complete DS200ADGIH1AAA marking and the assigned GE DS200/DC2000 drive-control hardware position before work.
Place the connected machine or process in the approved maintenance state before disturbing DS200ADGIH1AAA.
Isolate the applicable power and field energy, then confirm a safe state before disconnecting DS200ADGIH1AAA.
Record connector, conductor, slot and configuration identities before removal of DS200ADGIH1AAA.
Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies during handling.
Confirm that the installed companion hardware and approved project match the DS200ADGIH1AAA arrangement.
Restore power in a controlled sequence and review device, rack and host diagnostics.
Prove the intended function and retain the final test result before returning DS200ADGIH1AAA to service.
Technical notes
FAQ View All FAQ
-
Which connection records are needed before replacing DS200ADGIH1AAA?Record each connector, conductor, shield, polarity, jumper and position identifier in the as-found state.
-
How should energy be isolated before handling DS200ADGIH1AAA?Use the host-equipment isolation procedure, remove applicable control and field energy, discharge stored energy and prove the required safe state.
-
What compatibility checks apply to DS200ADGIH1AAA?Match DS200ADGIH1AAA to the exact host platform, assigned position, interfaces, hardware revision and approved project record.
-
How should engineers configure DS200ADGIH1AAA after installation?Restore only the approved installed-system settings and assignments; do not transfer parameters from a visually similar catalog number.
-
Which diagnostics should be reviewed when commissioning DS200ADGIH1AAA?Check local indications, host diagnostics, interlocks and the complete commanded or measured signal path before automatic operation.
-
How is the functional path of DS200ADGIH1AAA tested?Apply a controlled test from the originating command or field condition through the connected hardware and record the final response.
-
What maintenance evidence should be retained for DS200ADGIH1AAA?Retain the as-found record, installed position, revision identity, configuration reference, diagnostic state and signed acceptance result.
-
What installed system position is assigned to DS200ADGIH1AAA?Confirm the documented GE DS200/DC2000 drive-control hardware position, complete catalog identity and mating hardware before removing DS200ADGIH1AAA.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.