Match the complete marking
Include IC698CHS117 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered IC698CHS117 reference with the installed equipment and applicable GE documentation.
Technical specifications for IC698CHS117
-
Manufacturer:General Electric
-
Product Category:PLC Systems
-
Spare Part Number:IC698CHS117
-
Weight:6.16 kg
-
Tariff Code:8537101190
-
Universal module slots:17
-
Module-slot pitch:20.3 mm
-
Power-supply slot width:61.0 mm
-
Mounting execution:Front mount
-
Cabinet rail format:19-inch rack
-
Backplane architecture:VME64
-
100 W supply +5 V capacity:20 A
-
100 W supply +12 V capacity:2 A
-
100 W supply -12 V capacity:1 A
-
350 W supply +5 V capacity:60 A
-
350 W supply +12 V capacity:12 A
-
350 W supply -12 V capacity:4 A
-
Minimum protective enclosure:IP54
-
Ground stud:#8-32
Information
- GE IC698CHS117 is a pacsystems rx7i 17-slot front-mount rack documented for GE PACSystems RX7i controller platform.
Mixed RX7i/VME backplane: The VME64 rack supports approved RX7i and documented legacy VME or Series 90-70 modules.
Power-supply-dependent current budget: Available +5 V and ±12 V capacity changes with the selected 100 W or 350 W supply.
The VME64 backplane supports RX7i CPUs and I/O plus approved Series 90-70 and VME modules. Module selection must include backplane current demand, cooling and the installed CPU/power-supply combination.
Installation requires an IP54-or-better protective enclosure, the documented mounting orientation and earth connection through the rack ground stud. Commissioning checks supply rails, CPU recognition, slot inventory and representative I/O communication.
IC698CHS117 Technical Reference
Apter Power technical reference based on GE Fanuc PACSystems RX7i Racks datasheet GFK-2236A and RX7i Installation Manual GFK-2223; facts remain within the verified product and system evidence.IC698CHS117 Installation & Verification Guide
Product-specific field guide for identity capture, controlled exchange, commissioning evidence and handover.
Application scope: Apply IC698CHS117 only where the verified hardware execution, companion equipment and approved system record agree.
RX7i controller rack
Host the approved CPU, power supply and I/O arrangement.VME64 integration
Support documented compatible VME and legacy Series 90-70 modules.Front-mount cabinet service
Provide service access in a standard 19-inch rack.Installed-base expansion
Retain current budget, cooling and slot-assignment controls.
Do not substitute the rear-mount rack by catalog similarity.
Compare every module load with the selected supply capacities.
Keep the open rack inside the required protective cabinet.
Connect the #8-32 stud using the approved grounding method.
Capture CPU, I/O, VME and filler positions before exchange.
Verify rails, CPU start and slot recognition before field enable.
Alternative Names
Technical notes
Installed relationship: RX7i controller rack: Host the approved CPU, power supply and I/O arrangement.
Verified function: Front-service architecture: The rack mounts at the front of a standard 19-inch cabinet for module access from the service side.
Evidence boundary: GE Fanuc PACSystems RX7i Racks datasheet GFK-2236A and RX7i Installation Manual GFK-2223; Universal module slots is recorded as 17
Configuration control: Keep the open rack inside the required protective cabinet.
Acceptance basis: Confirm rail voltages, CPU startup, complete slot inventory, diagnostics and representative I/O communication.
FAQ View All FAQ
-
How is IC698CHS117 distinguished from IC698CHS017?IC698CHS117 is the 17-slot front-mount execution; IC698CHS017 is rear mounted.
-
Which slot in IC698CHS117 is reserved for the power supply?Slot 0 is the 61.0 mm power-supply position; module slots 1 through 17 are 20.3 mm wide.
-
How should the current budget for IC698CHS117 be calculated?Sum each installed module’s +5 V and ±12 V demand and compare it with the selected 100 W or 350 W supply limits.
-
Which enclosure requirement applies to IC698CHS117?The rack is open equipment and must be installed in an IP54-or-better protective enclosure.
-
How is protective earth connected to IC698CHS117?Use the rack #8-32 ground stud and the approved safety/reference-ground procedure.
-
Can every VME module be fitted in IC698CHS117?Only modules documented as compatible with the RX7i VME64 backplane and the installed system configuration should be used.
-
When is a fan assembly needed with IC698CHS117?Cooling depends on CPU, power supply and cabinet loading; use the RX7i installation rules for the exact installed combination.
-
What proves successful replacement of IC698CHS117?Confirm rail voltages, CPU startup, complete slot inventory, diagnostics and representative I/O communication.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-