Speak to a sourcing specialist
sales13@apterpower.com

IC698CRE030

PACSystems RX7i 600 MHz redundant CPU
In Stock
Ships by Thursday, November 12
Fast Shipping Available
General Electric IC698CRE030 redundant CPU module, top view of heatsink fins, daughter card and metal front plate
General Electric IC698CRE030 CPU faceplate, angled view with RUN/STOP enable switch, status LEDs and COM ports
General Electric IC698CRE030-BB label close-up, RX7i 600MHz CPU redundant with Ethernet 10/100 above heatsink fins
General Electric IC698CRE030 redundant CPU module, top view of heatsink fins, daughter card and metal front plate
General Electric IC698CRE030 CPU faceplate, angled view with RUN/STOP enable switch, status LEDs and COM ports
General Electric IC698CRE030-BB label close-up, RX7i 600MHz CPU redundant with Ethernet 10/100 above heatsink fins
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

General Electric IC698CRE030 is pacsystems rx7i 600 mhz redundant cpu. It executes PACSystems RX7i control logic as a redundancy CPU with embedded Ethernet and serial communications.
Get a quick price for IC698CRE030
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for IC698CRE030

  • Manufacturer:
    General Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC698CRE030
  • Estimated shipping dimensions:
    4.1x17.4x29.3cm
  • Weight:
    0.8 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Processor:
    Pentium M at 600 MHz
  • User memory:
    64 MB battery-backed RAM
  • Flash user memory:
    64 MB nonvolatile
  • Ethernet:
    Embedded 10/100 Mbit/s
  • Serial ports:
    3
  • Serial protocols:
    Modbus RTU slave; SNP; Serial I/O
  • Program blocks:
    Up to 512
  • Operating temperature:
    0 to 50 degC without fan; 0 to 60 degC with fan tray

Information

Overview Manuals Common Applications Product Precautions
General Electric IC698CRE030 is pacsystems rx7i 600 mhz redundant cpu. It executes PACSystems RX7i control logic as a redundancy CPU with embedded Ethernet and serial communications.
  • Uses a 600 MHz Pentium M processor
  • Provides 64 MB battery-backed user memory
  • Provides 64 MB nonvolatile flash memory
  • Integrates ten/one-hundred-megabit Ethernet

IC698CRE030 operates with RX7i VME64 rack, redundancy partner CPU, compatible redundancy links, Proficy Machine Edition project.

Engineered applications include Hot-standby process control, High-capacity RX7i logic, Ethernet EGD coordination, Redundant CPU replacement.

Important Notice: Back up the project, record primary/secondary roles, Ethernet and serial settings, battery state and firmware, then prove synchronization before switchover.

Apter Power GE IC698CRE030 Manuals and Guides

Apter Power GE IC698CRE030 Product and System Technical Reference PDFApter Power GE IC698CRE030 Installation and Commissioning Workbook PDF

The first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.

Hot-standby process control

Executes the redundant process application.

High-capacity RX7i logic

Synchronizes controller state with its partner.

Ethernet EGD coordination

Exchanges Ethernet Global Data and service traffic.

Redundant CPU replacement

Restores the CPU while preserving redundancy roles.

Read the applicable General Electric instructions before work. Verify IC698CRE030 and the installed GE PACSystems RX7i redundancy control configuration.
1

Verify the complete IC698CRE030 marking and its assigned GE PACSystems RX7i redundancy control position before work.

2

Place the connected hot-standby process control process in the approved maintenance state.

3

Isolate applicable power and redundant plc execution, ethernet data and serial communications field energy before disconnecting conductors.

4

Record connector, conductor, address, firmware and software identities before removal.

5

Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.

6

Confirm the installed RX7i VME64 rack and redundancy partner CPU against the approved project.

7

Restore power in a controlled sequence and review device, network and host diagnostics.

8

Prove the intended high-capacity rx7i logic function and retain the final test result.

Technical notes

Back up the project, record primary/secondary roles, Ethernet and serial settings, battery state and firmware, then prove synchronization before switchover.

FAQ View All FAQ

  • Which installed system position is intended for IC698CRE030?
    Install IC698CRE030 only in the documented GE PACSystems RX7i redundancy control position and compare the complete catalog marking with the approved hardware list.
  • What field signals or controlled function does IC698CRE030 handle?
    Its documented role is redundant plc execution, ethernet data and serial communications; preserve the assigned channel, network or controller function during service.
  • Which companion hardware must be matched to IC698CRE030?
    Match IC698CRE030 with RX7i VME64 rack and redundancy partner CPU, including the documented rack, cable and project identity.
  • Which electrical rating must be checked before wiring IC698CRE030?
    Verify user memory: 64 MB battery-backed RAM. Do not transfer limits from another catalog number.
  • What configuration should be recorded before replacing IC698CRE030?
    Record the as-found position, conductors, addressing, firmware and software revision, then restore only the approved GE PACSystems RX7i redundancy control configuration.
  • Which isolation and handling controls apply to IC698CRE030?
    Isolate all documented supply and field energy, use ESD controls and protect keyed connectors before handling IC698CRE030.
  • How should an engineer commission IC698CRE030?
    Power up in a controlled sequence, review device and host diagnostics, then prove the intended hot-standby process control function.
  • Can IC698CRE030 replace a visually similar module without an engineering review?
    No automatic substitution is assumed; compare the complete catalog number, interfaces, ratings and approved system revision.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.