GE IC695ACC400 is a PACSystems RX3i energy pack for CPE302, CPE305 and CPE310 controllers. During loss of system power, it supports the controller long enough to copy user memory to nonvolatile storage.
GE IC695ACC400 is a PACSystems RX3i energy pack for CPE302, CPE305 and CPE310 controllers. During loss of system power, it supports the controller long enough to copy user memory to nonvolatile storage.
Supports controlled user-memory retention during power loss
Designed for the documented RX3i CPE302, CPE305 and CPE310 controllers
Reports charging, charged, fault and low-capacitance status
Requires the exact controller and Energy Pack compatibility match
Apply GE IC695ACC400 only in the documented system position after checking its interfaces, companion hardware and configured values.
Important Notice: Confirm the full IC695ACC400 marking, installed revision, compatible hardware and approved commissioning record before release.
The first document presents model-specific technical and system data. The second provides a separate installation, connection, commissioning and acceptance workflow.
RX3i memory retention
Keeps the supported controller powered while user memory is written to nonvolatile storage.
Controller replacement
Preserves the approved Energy Pack arrangement when a compatible CPU is serviced.
Power-loss recovery
Supports the documented shutdown sequence for the compatible RX3i CPU.
Preventive maintenance
Uses status indications to identify charging, fault and capacitor-life conditions.
Read the applicable GE instructions before work. Verify GE IC695ACC400 and the installed system configuration before commissioning.
1
Verify the complete IC695ACC400 marking before installation.
2
Use IC695ACC400 only with the documented CPE302, CPE305 or CPE310 controller revision.
3
Remove system power and follow the current RX3i service procedure before handling the Energy Pack.
4
Inspect the Energy Pack cable and connectors before reconnection.
5
Do not substitute ACC402 or ACC403 for IC695ACC400 without checking controller compatibility.
6
Allow the Energy Pack to reach the documented charged state before relying on memory retention.
7
Check charging, fault, low-capacitance and charged status indications after startup.
8
Confirm a controlled power-loss memory-retention test before production release.
Technical notes
Use only the complete GE IC695ACC400 identity and the current manufacturer documentation. Verify the installed revision, companion hardware, wiring and saved configuration before replacement or release.