Product Describe:

FSP FSP400-60PFI is a 400 W industrial computer power supply. Its exact marking, installed interfaces and companion equipment must be verified before replacement or commissioning.
  • Manufacturer part number
    FSP400-60PFI
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    8.5cm x 15cm x 15cm
  • Country of Origin
    China
Get a quick price for FSP400-60PFI
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.

  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.

  • Match the complete marking

    Include FSP400-60PFI and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered FSP400-60PFI reference with the installed equipment and applicable FSP documentation.

Technical specifications for FSP400-60PFI

  • Manufacturer:
    FSP
  • Product Category:
    General Automation
  • Spare Part Number:
    FSP400-60PFI
  • Weight:
    2.02 kg
  • Tariff Code:
    8537101190
  • Rated output power:
    400 W
  • AC input range:
    100 to 240 V AC
  • Input frequency:
    50/60 Hz
  • Maximum marked input current:
    6.3 A
  • DC rail set:
    +3.3 V, +5 V, +12 V, -12 V and +5 V standby
  • 12 V architecture:
    Separate +12 V1 and +12 V2 rails are identified in cross-checked records
  • Power-good signal:
    P.G. signal lead identified in cross-checked wiring records
  • Protective conductor:
    Ground return conductors form part of the installed harness
  • Replacement rule:
    Match every connector position and rail assignment to the removed supply
  • Evidence boundary:
    Individual rail-current values are not published here because available records conflict

Information

Overview Downloads Applications / Compatibility Product Precautions
  • The complete FSP400-60PFI identity establishes the offered hardware. Confirm the installed system, revision and field interfaces before approving the replacement.
Engineering role: Multi-rail AC/DC supply for an industrial-computer chassis.
Replacement boundary: Rated wattage alone does not prove connector or rail compatibility.
Installation focus: Preserve harness position, chassis airflow and protective-earth continuity.
FSP400-60PFI converts a universal-range AC input into the multiple DC rails used by its installed industrial-computer platform. The complete supply label and harness layout are the primary replacement references.

A correct changeover requires connector-by-connector comparison, not only a 400 W match. Record the original plug positions, wire colours, standby rail, power-good lead and protective-earth path before removal.

Commissioning should verify standby behaviour, controlled start-up, each populated rail under load, fan direction and chassis temperature. If the delivered label differs from the recorded unit, hold the replacement for review.
Controller platform reference: Industrial computer power chassis. Verify the installed harness.
Technical downloads for FSP FSP400-60PFI: model-specific technical reference and installation review.
Use the manufacturer source identified in each document to confirm applicability to the installed configuration.
System and supply context: The offered item is FSP FSP400-60PFI, condition New, original product. Companion cables, terminal units, adapters and accessories are separate unless itemized in the quotation.

Platform applications: The uses below depend on the installed controller configuration and approved system design.
Prepare FSP FSP400-60PFI using the approved machine documentation and site procedure.
Record every connector

Photograph and label the full harness before removing any plug.

Discharge before handling

Isolate AC power and follow the approved wait and voltage-verification procedure.

Protect the earth path

Confirm protective-earth continuity between supply and chassis before energizing.

Check airflow

Keep the fan path, inlet and exhaust clear and confirm the installed orientation.

Prove standby first

Verify the standby rail and control signal before permitting full system start-up.

Test under representative load

Record populated-rail voltage and system stability under the approved operating load.

Alternative Names

FSP FSP400-60PFI FSP400 60PFI

Technical notes

Installation relationship: Use the exact model marking and manufacturer wiring or installation information for the delivered hardware.

System boundary: Verify host equipment, companion interfaces, field wiring and configuration before energizing.

Technical reference: cross-checked FSP400-60PFI nameplate data from multiple established industrial-parts records.

FAQ View All FAQ

  • How should the connector map of FSP400-60PFI be captured before removal?
    Photograph every plug from two angles, label its chassis destination, and record keying, latch direction, wire colours and unused positions before disconnecting the harness.
  • Which live checks are most useful when diagnosing FSP400-60PFI?
    Use the approved electrical-safety method to verify AC input, standby output, start command, populated DC rails and power-good state under the installed load.
  • How can an intermittent shutdown involving FSP400-60PFI be separated from a downstream fault?
    Correlate each rail with load current and temperature, then isolate approved loads systematically. Do not condemn the supply from an unloaded voltage check alone.
  • What must be verified before fitting a substitute for FSP400-60PFI?
    Compare the complete label, mechanical envelope, fan direction, connector count, keying, pin assignments, standby rail and power-good behaviour.
  • How should protective-earth integrity be proved for FSP400-60PFI?
    With power isolated, inspect the earth conductor and mounting points, then measure continuity using the site-approved method and record the result before energizing.
  • What thermal evidence should be recorded after installing FSP400-60PFI?
    Record inlet and exhaust condition, fan operation and stabilized chassis temperature while the computer runs its representative workload.
  • Why are individual rail-current values not assigned to FSP400-60PFI on this page?
    Available independent records disagree on several rail currents. Use the supplied nameplate and installed-system documentation as the controlling source.
  • What constitutes an acceptable as-left record for FSP400-60PFI?
    Retain label photographs, connector map, earth-continuity result, standby and loaded rail measurements, power-good behaviour and final operating observation.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.