Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for KJ3002X1-BC1 12P0681X092
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for KJ3002X1-BC1 12P0681X092

  • Manufacturer:
    Emerson
  • Product Category:
    DCS Systems
  • Spare Part Number:
    KJ3002X1-BC1 12P0681X092
  • Estimated shipping dimensions:
    5.1x12.7x12.7cm
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • I/O function:
    Analog input
  • Channels:
    8
  • Nominal signal:
    4 to 20 mA
  • Field-loop type:
    Two-wire current transmitters
  • Conversion:
    16-bit A/D family architecture
  • Calibration:
    Not required
  • Terminal relationship:
    Match installed key and terminal block
  • Configuration rule:
    Restore each channel from the approved project
  • Acceptance:
    Loop current, diagnostics and process scaling verified

Information

Overview Manuals Common Applications Product Precautions
KJ3002X1-BC1 12P0681X092 acquires eight current-loop measurements while keeping field wiring, supply and channel assignments under the original DeltaV engineering record.
  • KJ3002X1-BC1 12P0681X092
  • Analog input
  • 8
  • 4 to 20 mA

Retain the exact host position, connections and configuration record. Complete controlled diagnostics and a functional test before service release.

Important Notice: Confirm KJ3002X1-BC1 12P0681X092, every companion marking and the recorded acceptance result before replacement.

Emerson KJ3002X1-BC1 12P0681X092 Manuals & Downloads
Emerson KJ3002X1-BC1 12P0681X092 Technical Reference (PDF)Emerson KJ3002X1-BC1 12P0681X092 Installation & Commissioning Guide (PDF)

The technical reference consolidates product identity and interface data; the installation guide provides separate readiness, configuration, verification and handover checks.

Exact-position replacement
Matches KJ3002X1-BC1 12P0681X092 to the recorded host, position and companion hardware before changeout.
Interface restoration
Rebuilds the documented power, signal, keying and protective interfaces for KJ3002X1-BC1 12P0681X092.
Configuration-controlled service
Restores settings and assignments from the approved record rather than a neighboring module.
Acceptance and handover
Confirms diagnostics and the controlled functional response of KJ3002X1-BC1 12P0681X092 before release.
Read the applicable product and site instructions before work. Verify KJ3002X1-BC1 12P0681X092, the installed host and every connected interface before isolation or replacement.
1
Confirm the complete KJ3002X1-BC1 12P0681X092 marking and documented hardware role before work.
2
Place the connected process and controller hardware in the approved maintenance state.
3
Record the host position, companion parts, cable direction, terminal assignments and active configuration.
4
Isolate every documented power, signal and stored-energy source before disconnecting hardware.
5
Protect keyed connectors, electronic contacts and labeled field conductors during handling.
6
Restore only the recorded power, wiring, grounding, shielding and configuration arrangement.
7
Energize in a controlled sequence and review module, carrier, controller and field diagnostics.
8
Function-test acquisition of eight 4-20 mA field-current channels and retain the acceptance record before service release.

Technical notes

Use KJ3002X1-BC1 12P0681X092 only in the documented DeltaV M-series Traditional I/O execution. Preserve complete identity, interfaces and configuration, then verify diagnostics and acquisition of eight 4-20 mA field-current channels under controlled conditions.

FAQ View All FAQ

  • What is the documented role of KJ3002X1-BC1 12P0681X092?
    It is identified as a deltav 8-channel 4-20 ma analog input card used for acquisition of eight 4-20 mA field-current channels.
  • Why must the complete KJ3002X1-BC1 12P0681X092 identity be retained?
    The full model and suffix distinguish the installed execution from similar-looking revisions and related hardware.
  • Which value is documented for KJ3002X1-BC1 12P0681X092 i/o function?
    The verified product record gives i/o function as Analog input.
  • How is channels specified for KJ3002X1-BC1 12P0681X092?
    The verified product record gives channels as 8.
  • What does KJ3002X1-BC1 12P0681X092 nominal signal?
    The verified product record gives nominal signal as 4 to 20 mA.
  • Which setting applies to KJ3002X1-BC1 12P0681X092 field-loop type?
    The verified product record gives field-loop type as Two-wire current transmitters.
  • What should be verified for KJ3002X1-BC1 12P0681X092 conversion?
    The verified product record gives conversion as 16-bit A/D family architecture.
  • What closes a replacement of KJ3002X1-BC1 12P0681X092?
    Record the exact identity, restored interfaces, diagnostics and controlled functional result before release.