Speak to a sourcing specialist
sales13@apterpower.com

KJ3002X1-BE1 12P0682X052

DeltaV Analog Output Card
In Stock
Ships by Friday, November 6
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Emerson KJ3002X1-BE1 12P0682X052 is retained as the complete item marking for an eight-channel DeltaV analog-output position. Manufacturer documentation supports the KJ3002X1-BE1 base model as a 4-20 mA HART output card.
Get a quick price for KJ3002X1-BE1 12P0682X052
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for KJ3002X1-BE1 12P0682X052

  • Manufacturer:
    Emerson
  • Product Category:
    DCS Systems
  • Spare Part Number:
    KJ3002X1-BE1 12P0682X052
  • Estimated shipping dimensions:
    4.1x12.5x10.5cm
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Documented base model:
    KJ3002X1-BE1
  • Output channels:
    8
  • Signal range:
    4 to 20 mA
  • Digital protocol:
    HART pass-through
  • LocalBus power:
    12 V DC at 150 mA maximum
  • Field power:
    24 V DC at 300 mA maximum
  • Field circuit:
    24 V DC at 23 mA per channel
  • Conversion resolution:
    12 bit
  • Reference accuracy:
    0.25% of span
  • Operating temperature:
    -40 to 70°C
  • Storage temperature:
    -40 to 85°C
  • Relative humidity:
    5 to 95%, non-condensing
  • Airborne contaminants:
    ISA-S71.04-1985 G3

Information

Overview Manuals Common Applications Product Precautions
At the final-control boundary, KJ3002X1-BE1 converts eight DeltaV output values into individual 4-20 mA loops while passing supported HART communication. Loop loading, field supply, channel mapping and fail-state behavior must be verified in the installed system.
  • KJ3002X1-BE1 12P0682X052
  • KJ3002X1-BE1
  • 8
  • 4 to 20 mA

Retain the exact host position, connections and configuration record. Complete controlled diagnostics and a functional test before service release.

Important Notice: Confirm KJ3002X1-BE1 12P0682X052, every companion marking and the recorded acceptance result before replacement.

Emerson KJ3002X1-BE1 12P0682X052 Manuals & Downloads
Emerson KJ3002X1-BE1 12P0682X052 Technical Reference (PDF)Emerson KJ3002X1-BE1 12P0682X052 Installation & Commissioning Guide (PDF)

The technical reference consolidates product identity and interface data; the installation guide provides separate readiness, configuration, verification and handover checks.

Final-control output
Drives eight documented 4-20 mA field loops from the DeltaV I/O subsystem.
HART device communication
Passes supported HART data through each configured analog-output path.
Loop-load validation
Confirms field supply, load and terminal arrangement before enabling outputs.
Controlled stroke testing
Checks each connected final element under the approved maintenance procedure.
Read the applicable product and site instructions before work. Verify KJ3002X1-BE1 12P0682X052, the installed host and every connected interface before isolation or replacement.
1
Confirm the complete Emerson KJ3002X1-BE1 12P0682X052 marking against the receiving record before work.
2
Place the connected process, rack, machinery and control functions in the approved maintenance state.
3
Record the installed position, wiring, terminal hardware, settings and companion components before removal.
4
Isolate every affected electrical and process-energy source and verify the safe state.
5
Protect keyed connectors, terminals and electronics from contamination, strain and electrostatic damage.
6
Restore only the recorded wiring, grounding, shielding, settings and matched companion hardware.
7
Energize in the controlled sequence and review every available module, rack and system diagnostic.
8
Function-test eight-channel HART analog output and retain the signed acceptance result before service release.

Technical notes

Evidence boundary: Official base-model evidence; complete item marking retained exactly. Use Emerson KJ3002X1-BE1 12P0682X052 only after the physical marking, installed position, terminal hardware and companion equipment have been reconciled.

FAQ View All FAQ

  • What is the documented purpose of Emerson KJ3002X1-BE1 12P0682X052?
    Emerson KJ3002X1-BE1 12P0682X052 is retained as the complete item marking for an eight-channel DeltaV analog-output position. Manufacturer documentation supports the KJ3002X1-BE1 base model as a 4-20 mA HART output card.
  • Which product family contains Emerson KJ3002X1-BE1 12P0682X052?
    The documented base model belongs to the DeltaV M-series product family.
  • Which function is documented for Emerson KJ3002X1-BE1 12P0682X052?
    For the documented base model, output channels is 8.
  • What channel or interface detail applies to Emerson KJ3002X1-BE1 12P0682X052?
    For the documented base model, signal range is 4 to 20 mA.
  • Which power boundary applies to Emerson KJ3002X1-BE1 12P0682X052?
    For the documented base model, digital protocol is HART pass-through.
  • Which environmental limit applies to Emerson KJ3002X1-BE1 12P0682X052?
    For the documented base model, localbus power is 12 V DC at 150 mA maximum.
  • What diagnostic or maintenance point applies to Emerson KJ3002X1-BE1 12P0682X052?
    For the documented base model, field power is 24 V DC at 300 mA maximum.
  • What should be verified after installing Emerson KJ3002X1-BE1 12P0682X052?
    Verify the complete marking, installed interfaces, retained settings, diagnostics and controlled operation of eight-channel HART analog output before release.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.