Emerson KJ3002X1-BA1 12P06801X122 is preserved exactly as supplied for a DeltaV analog-input position. Official documentation supports the KJ3002X1-BA1 base model as an eight-channel, two-wire 4-20 mA HART input card; the unusual 12P06801X122 string is not silently corrected.
Get a quick price for KJ3002X1-BA1 12P06801X122
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for KJ3002X1-BA1 12P06801X122

  • Manufacturer:
    Emerson
  • Product Category:
    DCS Systems
  • Spare Part Number:
    KJ3002X1-BA1 12P06801X122
  • Estimated shipping dimensions:
    4.1x12.4x10.3cm
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Documented base model:
    KJ3002X1-BA1
  • Input channels:
    8
  • Input topology:
    2-wire transmitter
  • Signal range:
    4 to 20 mA
  • Digital protocol:
    HART pass-through
  • LocalBus power:
    12 V DC at 150 mA maximum
  • Field power:
    24 V DC at 300 mA maximum
  • Field circuit:
    24 V DC at 32 mA per channel
  • Operating temperature:
    -40 to 70°C
  • Storage temperature:
    -40 to 85°C
  • Relative humidity:
    5 to 95%, non-condensing
  • Airborne contaminants:
    ISA-S71.04-1985 G3

Information

Overview Manuals Common Applications Product Precautions
In the two-wire transmitter path, KJ3002X1-BA1 receives eight loop-current signals and passes supported HART data into the DeltaV system. The complete marking must be checked against the physical label before the page is used for procurement or replacement.
  • KJ3002X1-BA1 12P06801X122
  • KJ3002X1-BA1
  • 8
  • 2-wire transmitter

Retain the exact host position, connections and configuration record. Complete controlled diagnostics and a functional test before service release.

Important Notice: Confirm KJ3002X1-BA1 12P06801X122, every companion marking and the recorded acceptance result before replacement.

Emerson KJ3002X1-BA1 12P06801X122 Manuals & Downloads
Emerson KJ3002X1-BA1 12P06801X122 Technical Reference (PDF)Emerson KJ3002X1-BA1 12P06801X122 Installation & Commissioning Guide (PDF)

The technical reference consolidates product identity and interface data; the installation guide provides separate readiness, configuration, verification and handover checks.

Two-wire transmitter input
Supplies and reads eight compatible 4-20 mA field loops.
HART maintenance access
Passes supported digital communication through the analog-input path.
Loop-power verification
Checks field supply, polarity and terminal mapping before connection.
Identity exception control
Preserves the extra digit in 12P06801X122 until the physical label is verified.
Read the applicable product and site instructions before work. Verify KJ3002X1-BA1 12P06801X122, the installed host and every connected interface before isolation or replacement.
1
Confirm the complete Emerson KJ3002X1-BA1 12P06801X122 marking against the receiving record before work.
2
Place the connected process, rack, machinery and control functions in the approved maintenance state.
3
Record the installed position, wiring, terminal hardware, settings and companion components before removal.
4
Isolate every affected electrical and process-energy source and verify the safe state.
5
Protect keyed connectors, terminals and electronics from contamination, strain and electrostatic damage.
6
Restore only the recorded wiring, grounding, shielding, settings and matched companion hardware.
7
Energize in the controlled sequence and review every available module, rack and system diagnostic.
8
Function-test eight-channel two-wire HART analog input and retain the signed acceptance result before service release.

Technical notes

Evidence boundary: Official base-model evidence; complete item marking retained exactly. Use Emerson KJ3002X1-BA1 12P06801X122 only after the physical marking, installed position, terminal hardware and companion equipment have been reconciled.

FAQ View All FAQ

  • What is the documented purpose of Emerson KJ3002X1-BA1 12P06801X122?
    Emerson KJ3002X1-BA1 12P06801X122 is preserved exactly as supplied for a DeltaV analog-input position. Official documentation supports the KJ3002X1-BA1 base model as an eight-channel, two-wire 4-20 mA HART input card; the unusual 12P06801X122 string is not silently corrected.
  • Which product family contains Emerson KJ3002X1-BA1 12P06801X122?
    The documented base model belongs to the DeltaV M-series product family.
  • Which function is documented for Emerson KJ3002X1-BA1 12P06801X122?
    For the documented base model, input channels is 8.
  • What channel or interface detail applies to Emerson KJ3002X1-BA1 12P06801X122?
    For the documented base model, input topology is 2-wire transmitter.
  • Which power boundary applies to Emerson KJ3002X1-BA1 12P06801X122?
    For the documented base model, signal range is 4 to 20 mA.
  • Which environmental limit applies to Emerson KJ3002X1-BA1 12P06801X122?
    For the documented base model, digital protocol is HART pass-through.
  • What diagnostic or maintenance point applies to Emerson KJ3002X1-BA1 12P06801X122?
    For the documented base model, localbus power is 12 V DC at 150 mA maximum.
  • What should be verified after installing Emerson KJ3002X1-BA1 12P06801X122?
    Verify the complete marking, installed interfaces, retained settings, diagnostics and controlled operation of eight-channel two-wire HART analog input before release.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.