Match the complete marking
Include 81545-01 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 81545-01 reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 81545-01
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:81545-01
-
Weight:0.4 kg
-
Tariff Code:8537101190
-
Module class:Signal input relay module
-
Relay construction:Epoxy sealed
-
Documented host:3300/48 Case Expansion Monitor
-
Host signal channels:2 LVDT inputs
-
Associated recorder outputs:Channel A and Channel B
-
Associated alarm contacts:Alert and Danger relay contacts
-
Host input impedance:230 kohm per LVDT input
-
Host transducer power:+15 V DC and -15 V DC
Information
- 81545-01 is the epoxy-sealed signal input relay module identified in the 3300/48 Case Expansion Monitor service parts list.
Host path: Interfaces the monitor's dual LVDT signal wiring with recorder and alarm-relay circuits.
Replacement limit: Match the exact 81545-01 relay construction and installed terminal mapping.
The service manual distinguishes no-relay, epoxy-sealed and hermetically sealed module variants. Preserve the 81545-01 construction selection rather than substituting another listed relay option by appearance.
Replacement acceptance should compare board and terminal markings, capture every channel and relay wire, inspect the mating connector and then prove both LVDT channels, recorder outputs and alarm contacts through the monitor test procedure.
-
Bently Nevada 81545-01 official technical excerpt
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
Bently Nevada 81545-01 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
3300/48 service
Maintain the signal and relay interface in a documented Case Expansion Monitor installation. -
Dual LVDT channel
Preserve Channel A and Channel B field wiring and recorder-output assignments. -
Alarm relay interface
Restore alert and danger contact wiring exactly as recorded for the installed monitor. -
Legacy spare management
Keep the epoxy-sealed 81545-01 identity separate from no-relay and hermetically sealed options.
Confirm the installed 3300 monitor model and complete module marking before removal.
Label Channel A and Channel B LVDT and recorder wiring separately.
Photograph alert and danger contact wiring and the intended normal state.
Use ESD controls and inspect contacts for corrosion, contamination or bent pins.
Do not replace the epoxy-sealed module with another relay option without approved host documentation.
Test both LVDT channels, recorder outputs and alarm contacts before release.
Alternative Names
Technical notes
Construction selection: Use the epoxy-sealed 81545-01 option only where the installed parts record calls for it.
Channel relationship: Keep LVDT, recorder and alarm-contact wiring separated by channel and function.
Acceptance focus: Prove both measurement channels and every required alert/danger contact through the host monitor.
FAQ View All FAQ
-
What relay construction is identified for 81545-01?The 3300/48 service parts list identifies 81545-01 as the epoxy-sealed relay version of the signal input relay module.
-
Which monitor documents 81545-01 in the reviewed manual?The reviewed service manual lists it for the Bently Nevada 3300/48 Case Expansion Monitor.
-
How is 81545-01 distinguished from 81544-01 and 81546-01?81544-01 is the no-relay option, 81545-01 uses epoxy-sealed relays and 81546-01 uses hermetically sealed relays.
-
What wiring must be recorded before removing 81545-01?Record both LVDT inputs, Channel A/B recorder outputs and alert/danger relay-contact conductors.
-
Do the host input values make 81545-01 a standalone monitor?No. The documented channel impedance and transducer supply belong to the 3300/48 host-monitor interface.
-
What connector checks apply to 81545-01?Inspect board-edge and mating contacts for contamination, corrosion, heat damage and bent or recessed contacts under ESD control.
-
When should 81545-01 be withheld from service?Withhold it if relay construction, host identity, terminal mapping or channel-test results differ from the installed record.
-
How should 81545-01 be accepted after replacement?Prove both LVDT readings, both recorder outputs and every required alert and danger contact using the host monitor test procedure.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.