Match the complete marking
Compare the complete Bently Nevada 330851-02-000-030-10-00-00 marking, hardware configuration and connections with the installed item before approving a replacement.
-
Check the offered item before ordering
Request clear label and connector photographs of Bently Nevada 330851-02-000-030-10-00-00. Ask your maintenance team to compare the offered item with the installed equipment and the applicable Bently Nevada 3300 XL 25 mm Proximity Transducer System, 163236 Rev. M before ordering.
Technical specifications for 330851-02-000-030-10-00-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330851-02-000-030-10-00-00
-
Weight:0.26 kg
-
Tariff Code:8537101190
-
Transducer family:3300 XL 25 mm
-
Mounting thread:M30×2
-
Overall case length:30 mm
-
Unthreaded-length selection:0 mm
-
Total probe lead:1.0 m
-
Lead armor:None
-
Probe resistance, center to outer:6.2 ± 0.5 Ω
-
Probe tip / case material:PEEK / AISI 304 stainless steel
-
Cable construction:75 Ω triaxial, PFA-insulated FluidLoc
-
Matched-system scale factor:0.787 V/mm nominal
-
Matched-system linear range:12.7 mm under specified calibration conditions
-
Probe continuous temperature:-35 to +200 °C
Information
- Bently Nevada 330851-02-000-030-10-00-00 supports non-contact observation of rotor growth relative to the turbine casing. The compact threaded case places the sensing face close to a turbine differential-expansion target, while its short lead connects into a separately matched extension-cable chain.
Integral lead: 1.0 m unarmored FluidLoc cable
Matched-system output: 0.787 V/mm nominal
The 1 m probe lead combines with the appropriate 4 m or 8 m extension cable to form a 5 m or 9 m system using the matching 3300 XL 25 mm Proximitor Sensor. Disconnected probe resistance from center to outer conductor is 6.2 ± 0.5 Ω. Cable and conditioner selection must preserve the complete electrical length.
For the complete matched system, nominal sensitivity is 0.787 V/mm and the linear range is 12.7 mm. The reference conditions include a -24 Vdc supply, a 10 kΩ load, a Bently Nevada AISI 4140 steel target at least 61 mm in diameter, a 7 mm gap and component temperatures from 0 to +45 °C. Probe survivability to +200 °C does not make these reference accuracy conditions universal.
330851-02-000-030-10-00-00 Original Technical Excerpt
Original Bently Nevada pages explain the 25 mm sensing system, calibrated response, materials and applicable cable options. PDF · 6 pages.330851-02-000-030-10-00-00 Installation & Verification Guide
Apter Power field guide covering short-lead system assembly, connector protection and displacement verification. PDF · 5 pages.
Application scope: Differential-expansion performance depends on the collar or ramp geometry, target material and configured channel arrangement. Mechanical fit alone does not establish electrical or calibration compatibility.
Short-lead system assembly
Verify the 1 m probe and the selected 4 m or 8 m extension as one 5 m or 9 m electrical-length chain.Turbine collar observation
Measure differential rotor-to-casing growth with a correctly aligned and gapped matched transducer chain.Complementary DE channels
Use opposing collar faces only with the intended two-channel arrangement and corresponding monitor configuration.Controlled displacement verification
Move the probe mounting relative to the target and compare the electrical indication with a mechanical movement reference.
The 1 m probe lead combines with the appropriate 4 m or 8 m extension cable to form a 5 m or 9 m system using the matching 3300 XL 25 mm Proximitor Sensor.
Keep the high-temperature ClickLoc connector clean, finger tight and inside its connector protector.
Use the intended collar or ramp surface and verify the target material against the calibration.
Do not apply probe-body tightening torque to the electrical connector; connector maximum is 0.565 N·m.
Apply probe, cable and Proximitor Sensor temperature limits separately; avoid treating short-term exposure as continuous service.
Test the complete channel through controlled relative movement before restoring the machine protection function.
Alternative Names
Technical notes
Electrical relationship: The 1 m probe lead combines with the appropriate 4 m or 8 m extension cable to form a 5 m or 9 m system using the matching 3300 XL 25 mm Proximitor Sensor. Disconnected probe resistance from center to outer conductor is 6.2 ± 0.5 Ω. Cable and conditioner selection must preserve the complete electrical length.
Measurement boundary: For the complete matched system, nominal sensitivity is 0.787 V/mm and the linear range is 12.7 mm. The reference conditions include a -24 Vdc supply, a 10 kΩ load, a Bently Nevada AISI 4140 steel target at least 61 mm in diameter, a 7 mm gap and component temperatures from 0 to +45 °C. Probe survivability to +200 °C does not make these reference accuracy conditions universal.
Technical reference: Bently Nevada 3300 XL 25 mm Proximity Transducer System, 163236 Rev. M.
FAQ View All FAQ
-
Which electrical-length combinations work with 330851-02-000-030-10-00-00?The integral lead is 1.0 m. Use the appropriate 4.0 m or 8.0 m extension cable to complete a 5 m or 9 m calibrated system with the corresponding 3300 XL 25 mm Proximitor Sensor.
-
Why is 330851-02-000-030-10-00-00 suited to differential-expansion measurements?In a matched 25 mm system, the nominal scale factor is 0.787 V/mm and the linear range is 12.7 mm. That range supports observation of turbine rotor growth relative to the casing; the target and mounting arrangement still determine the usable measurement geometry.
-
What resistance check is appropriate for the lead of 330851-02-000-030-10-00-00?For the 1.0 m probe, resistance from the center conductor to the outer conductor is 6.2 ± 0.5 Ω. Measure the disconnected probe path under the maintenance procedure and keep it separate from extension-cable resistance.
-
Does the short case of 330851-02-000-030-10-00-00 remove the need to check mounting clearance?No. The M30×2 case has a 30 mm overall case length and a zero unthreaded-length selection. Check the thread engagement, target clearance and connector route against the actual machine installation.
-
Can 330851-02-000-030-10-00-00 be mixed with an older 7200 extension cable during an upgrade?No. An upgrade from the older 7200 or 25 mm DE Integral system requires the probe, extension cable and Proximitor Sensor to be changed together to 3300 XL 25 mm components.
-
How should the ClickLoc connection on 330851-02-000-030-10-00-00 be protected from moisture?Use the supplied connector protectors and keep the connector clean during assembly. The front and rear probe seals and FluidLoc lead help block moisture migration, but the connected system is non-submersible.
-
What is the nominal linear gap interval for a system using 330851-02-000-030-10-00-00?Under the specified calibration conditions, the interval is approximately 0.63–13.33 mm, corresponding to about -1.5 to -11.5 Vdc. These values describe the matched system rather than an unconditioned probe output.
-
How can the measurement chain containing 330851-02-000-030-10-00-00 be checked mechanically?Move the installed transducer arrangement relative to the shaft collar to simulate displacement and compare the indicated change with a mechanical reference. An appropriate sliding bracket keeps the probe aligned during this verification.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.