Match the complete marking
Include 330704-00-050-10-01-05 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 330704-00-050-10-01-05 reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 330704-00-050-10-01-05
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330704-00-050-10-01-05
-
Weight:0.55 kg
-
Tariff Code:8537101190
-
Probe family:3300 XL 11 mm
-
Mounting thread:M14 x 1.5
-
Cable armor:Stainless-steel armor
-
Unthreaded length:0 mm
-
Overall case length:50 mm
-
Total probe length:1.0 m
-
Connector:Miniature coaxial ClickLoc with connector protector, standard cable
-
Approval selection:Multiple approvals
-
Nominal probe DC resistance:5.9 +/- 0.5 ohm
-
Matched-system linear range:4.0 mm (160 mil); approximately 0.5 to 4.5 mm gap
-
Matched-system scale factor:3.94 V/mm (100 mV/mil)
-
Recommended gap:2.5 mm (100 mil)
-
Proximitor supply:-17.5 to -26 V DC; 12 mA maximum without barriers
-
Output resistance:50 ohm
-
Supported system lengths:5 m or 9 m
-
Probe temperature:-52 to +177 deg C, operating and storage
-
Reference target:AISI 4140 steel
Information
- Bently Nevada 330704-00-050-10-01-05 is an 11 mm eddy-current proximity probe for the 3300 XL family, used where a longer linear measurement range is required than the standard 8 mm system can provide.
Lead and connector: 1.0 m; Miniature coaxial ClickLoc with connector protector, standard cable.
Matched-system span: 4.0 mm linear range with a 2.5 mm recommended gap.
The 1.0 m lead uses miniature coaxial clickloc with connector protector, standard cable. Preserve the 5 m or 9 m electrical-length relationship, keep the ClickLoc interface clean and dry, and support the armor independently of the joint.
The 4.0 mm range and 3.94 V/mm scale factor apply only to the complete matched 11 mm system on the stated reference target. Final acceptance must restore the approved gap and prove the monitor response against the machine baseline.
-
Bently Nevada 330704-00-050-10-01-05 official technical excerpt
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
Bently Nevada 330704-00-050-10-01-05 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
Radial shaft vibration
Use a documented bearing location and matched transducer chain to measure shaft motion relative to the probe mounting. -
Axial position
Aim the probe at an approved conductive thrust target and keep the full expected travel inside the characterized working region. -
Phase or speed reference
Use only with an approved once-per-turn target feature and a monitoring channel configured for phase or speed reference. -
Installed-channel maintenance
Preserve the exact probe, cable, Proximitor, mounting geometry and machine baseline recorded for the existing channel.
Match every field of 330704-00-050-10-01-05 with the installed spare-parts record before removal or installation.
Keep the probe tip, connector and cable free from impact, moisture, metal chips and unsupported loading.
Record reach, thread engagement, lock position and target relationship before disturbing the installed component.
Maintain the approved bend radius, separation and strain relief; do not twist, kink or crush the coaxial path.
Use the approved stopped-machine procedure to restore gap or bias and verify expected target travel.
Verify the as-left electrical reading, monitor indication and operating response before return to service.
Alternative Names
Technical notes
Installation relationship: The M14 x 1.5 mounting, 0 mm reach and 50 mm case establish the probe position; the armor needs independent support.
Electrical boundary: Use the 1.0 m probe and miniature coaxial clickloc with connector protector, standard cable only inside the documented 3300 XL 11 mm chain.
Technical reference: Bently Nevada 3300 XL 11 mm Proximity Transducer System Datasheet, 146256 Rev. T.
FAQ View All FAQ
-
Which Proximitor and extension cable belong with 330704-00-050-10-01-05?Use only 3300 XL 11 mm companion components whose probe lead plus extension cable equals the selected 5 m or 9 m system length.
-
How should the 50 mm case of 330704-00-050-10-01-05 be checked mechanically?Compare the M14 x 1.5 port, 0 mm unthreaded section, 50 mm case, armor clearance and target travel with the approved machine drawing.
-
Why does 330704-00-050-10-01-05 need a larger target review than an 8 mm probe?The 11 mm system has a 4.0 mm linear span and different target-size and cross-talk requirements. Verify the actual target geometry and tip separation before applying the published scale factor.
-
How should the connector protector selected on 330704-00-050-10-01-05 be installed?Inspect and fully seat the ClickLoc joint finger-tight, then fit the protector without twisting the coaxial lead or transferring armor load into the connector.
-
What evidence should be captured before removing 330704-00-050-10-01-05?Photograph the complete 330704-00-050-10-01-05 marking, installed datum, connector, cable route and companion electronics. Record the stopped-machine baseline for the 3300 XL 11 mm proximity probe.
-
How should connector integrity be checked on 330704-00-050-10-01-05?Isolate the channel, inspect the coaxial contacts for moisture and damage, verify continuity only with an approved method, and provide strain relief so the connector carries no cable load.
-
What commissioning record is required for 330704-00-050-10-01-05?Retain the exact markings, mechanical datum, companion-component identities, as-left gap or bias, monitor indication and the accepted operating response.
-
When should 330704-00-050-10-01-05 be withheld from service?Do not release the channel if the complete identity, mechanical fit, cable construction, connector, approval marking or measured response differs from the approved installed record.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
330704-00-050-10-01-05Product Details -
330908-00-36-05-02-05Product Details -
330104-12-20-10-02-00Product Details -
330104-00-16-10-02-05Product Details -
330103-00-02-10-02-00Product Details -
330103-00-10-05-02-05Product Details -
330101-00-14-10-02-05Product Details -
330103-00-22-10-12-05Product Details -
330101-00-20-05-02-05Product Details -
330103-06-15-10-12-05Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.