Bently
View products
The 5 mm probe interfaces with the documented matched transducer system and must not be mixed with unrelated probe families. Mounting clearance and target size require particular attention because of the smaller tip.
Important Notice: Match the complete 330173-00-05-10-02-00 marking before removing the installed probe. Verify proportional voltage response, polarity and channel indication before returning the machine to service.
The first document covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.