Product Describe:

Bently Nevada 3300/65-13-01-00-00-01-00 is a 3300/65 Dual Probe Monitor configured for 0–400 µm pp with 3300/7200 Proximitor dual-probe input; its selected hardware provides Epoxy-sealed alarm relays, a standard unbarriered input interface, no agency-approval option selected, the base displayed range.
Get a quick price for 3300/65-13-01-00-00-01-00
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 3300/65-13-01-00-00-01-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    3300/65-13-01-00-00-01-00
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Measurement function:
    combined shaft-relative and casing motion
  • Selected range:
    0–400 µm pp
  • Input system:
    3300/7200 Proximitor dual-probe input
  • Signal sensitivity:
    200 mV/mil where specified by the selected input
  • Alarm relay option:
    Epoxy-sealed
  • Safety-barrier option:
    None
  • Agency approval option:
    None
  • Range multiplier:
    None
  • Channel test method:
    Controlled input change, one channel at a time
  • Configuration identity:
    Complete order code required

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 3300/65-13-01-00-00-01-00 applies dual-probe measurement combining a proximity signal with a seismic transducer signal to absolute shaft vibration on fluid-film bearing machines, using the exact 0–400 µm pp scale and the selected interface options.
  • Uses the selected 0–400 µm pp measurement range.
  • Accepts 3300/7200 Proximitor dual-probe input.
  • Uses epoxy-sealed alarm relay hardware.
  • Uses the base range without a multiplication option.

The complete channel must preserve the transducer source, displayed range, relay interface and barrier selection together. A monitor from the same family can produce a plausible indication while applying a different scale or output arrangement.

Important Notice: Match the complete 3300/65-13-01-00-00-01-00 order code, input source and rear connection assembly before installation; then verify each channel through a controlled response test.

Bently Nevada 3300/65-13-01-00-00-01-00 Manuals & Downloads
Bently Nevada 3300/65-13-01-00-00-01-00 Technical Reference (PDF)Bently Nevada 3300/65-13-01-00-00-01-00 Installation & Commissioning Guide (PDF)

The technical reference, installation guide and complete product information PDF are separate documents with different scopes. All three apply only to the exact model shown.

Absolute Shaft Vibration On Fluid-Film Bearing Machines
Apply the selected 0–400 µm pp span to the intended machine measurement.
Two-channel condition monitoring
Keep channel identity from the field transducer through indication and alarms.
Controlled maintenance testing
Inject or apply a known change and compare each response stage.
Protection-system integration
Verify the selected relay and barrier interface with the receiving circuit.
Apply these checks to the exact Bently Nevada 3300/65-13-01-00-00-01-00 configuration before isolation, replacement or return to service.
1
Confirm the full 3300/65-13-01-00-00-01-00 marking before removing the installed monitor.
2
Record both channel readings and the selected 0–400 µm pp scale before isolation.
3
Preserve the 3300/7200 Proximitor dual-probe input transducer and sensitivity selection.
4
Retain the epoxy-sealed relay arrangement and its contact logic.
5
Do not introduce a safety barrier without reviewing the complete input loop.
6
Do not infer an agency approval from another order-code variant.
7
Verify the base range is used without multiplication.
8
Test each channel, alarm state and downstream response before returning protection to service.

Technical notes

Use a controlled input condition to verify the 0–400 µm pp scale, 3300/7200 Proximitor dual-probe input conversion, channel identity and selected output behavior. Restore the recorded alarm, delay, reset, multiplier and bypass states only after the complete path responds correctly.

FAQ View All FAQ

  • Can 3300/65-13-01-00-00-01-00 use setpoints copied from a monitor with a different range?
    The selected measurement span is 0–400 µm pp. Alarm and recorder scaling must be checked against that span rather than copied from a different range option.
  • How should the 3300/7200 Proximitor dual-probe input source be checked before connecting 3300/65-13-01-00-00-01-00?
    This configuration uses 3300/7200 Proximitor dual-probe input. Preserve the transducer family, sensitivity and signal polarity as one measurement chain.
  • How should the epoxy-sealed alarm relays in 3300/65-13-01-00-00-01-00 be tested?
    The selected alarm output uses epoxy-sealed relay hardware. Contact logic, energization and downstream wiring still require a functional test.
  • Can a safety barrier be added to 3300/65-13-01-00-00-01-00 without reviewing the signal loop?
    No safety-barrier option is selected. Do not move field conductors from a barrier-equipped circuit without an engineering review.
  • Why does a similar approved monitor not establish approval for 3300/65-13-01-00-00-01-00?
    No agency-approval option is selected in this order code. Do not infer an approval from another unit in the same monitor family.
  • Why must multiplier jumpers be checked even though 3300/65-13-01-00-00-01-00 selects no multiplication?
    No range multiplier is selected, so the stated scale is the active base range. A multiplied setting from another monitor must not be transferred.
  • Which functional test should precede return of 3300/65-13-01-00-00-01-00 to service?
    Apply a controlled input change to one identified channel at a time, then compare the local indication, buffered or recorder signal, alarm state and return to normal.
  • Which technical settings should be recorded after commissioning 3300/65-13-01-00-00-01-00?
    Record the complete model, 0–400 µm pp scale, 3300/7200 Proximitor dual-probe input input, relay and barrier choices, channel assignments, setpoints, delays and the observed acceptance results.
Related reading

Related cases and sourcing guidance

View all case studies